{"title":"V-Bank Air Filters","description":"\u003cp\u003e\u003cstrong\u003eV-Bank air filters\u003c\/strong\u003e for commercial and industrial HVAC systems, available in \u003cem\u003e\u003cstrong\u003ehigh-efficiency microglass and synthetic media\u003c\/strong\u003e\u003c\/em\u003e with multiple MERV ratings, sizes, and V-bank configurations.\u003c\/p\u003e","products":[{"product_id":"v-bank-microglass-air-filter","title":"V-Bank Microglass Air Filter","description":"\u003cdiv class=\"accurafil-product-description\"\u003e\n\n  \u003c!-- =========================================================\n       PRODUCT INTRODUCTION\n       ========================================================= --\u003e\n\n  \u003csection class=\"product-intro\" aria-labelledby=\"product-description-heading\"\u003e\n\n    \u003cp class=\"product-eyebrow\"\u003e\n      High-Efficiency Glass Fiber HVAC Filtration\n    \u003c\/p\u003e\n\n    \u003ch2 id=\"product-description-heading\"\u003e\n      V-Bank Microglass Air Filter\n    \u003c\/h2\u003e\n\n    \u003cp\u003e\n      AccuraFil V-Bank Microglass Air Filters combine\n      \u003cstrong\u003emini-pleat glass fiber media with rigid V-bank construction\u003c\/strong\u003e\n      to provide high-efficiency particulate filtration with efficient\n      airflow and low resistance. The V-bank configuration increases the\n      effective media surface area within a compact filter footprint,\n      making the design suitable for high-airflow HVAC applications.\n    \u003c\/p\u003e\n\n    \u003cp\u003e\n      Available in \u003cstrong\u003eMERV 11, MERV 13, MERV 14, and MERV 15\u003c\/strong\u003e\n      configurations according to ASHRAE 52.2, corresponding to\n      \u003cstrong\u003eM6, F7, F8, and F9\u003c\/strong\u003e classifications under EN 779.\n      The filter uses synthetic glass fiber media with polyurethane potting,\n      thermoplastic bead separators, and a non-metallic ABS plastic frame\n      with a 20 mm header.\n    \u003c\/p\u003e\n\n    \u003cp\u003e\n      The fully incinerable construction is designed for compatible\n      pharmaceutical, healthcare, food processing, commercial, industrial,\n      VAV, air handler, and built-up filter bank applications where high\n      airflow, compact construction, and simplified filter disposal are\n      important considerations.\n    \u003c\/p\u003e\n\n  \u003c\/section\u003e\n\n\n  \u003c!-- =========================================================\n       KEY BENEFITS\n       ========================================================= --\u003e\n\n  \u003csection class=\"product-section\" aria-labelledby=\"key-benefits-heading\"\u003e\n\n    \u003ch2 id=\"key-benefits-heading\"\u003e\n      Key Benefits\n    \u003c\/h2\u003e\n\n    \u003cdiv class=\"benefits-grid\"\u003e\n\n      \u003carticle class=\"benefit-card\"\u003e\n\n        \u003ch3\u003e\n          High-Efficiency Microglass Media\n        \u003c\/h3\u003e\n\n        \u003cp\u003e\n          Synthetic glass fiber media provides high-efficiency particulate\n          filtration across MERV 11 through MERV 15 configurations.\n        \u003c\/p\u003e\n\n      \u003c\/article\u003e\n\n\n      \u003carticle class=\"benefit-card\"\u003e\n\n        \u003ch3\u003e\n          Mini-Pleat V-Bank Design\n        \u003c\/h3\u003e\n\n        \u003cp\u003e\n          The extended-surface mini-pleat configuration increases effective\n          media area within a compact rigid V-bank filter footprint.\n        \u003c\/p\u003e\n\n      \u003c\/article\u003e\n\n\n      \u003carticle class=\"benefit-card\"\u003e\n\n        \u003ch3\u003e\n          Polyurethane-Potted Media Pack\n        \u003c\/h3\u003e\n\n        \u003cp\u003e\n          Polyurethane potting bonds the media pack to the frame and provides\n          enhanced burst resistance for demanding airflow conditions.\n        \u003c\/p\u003e\n\n      \u003c\/article\u003e\n\n\n      \u003carticle class=\"benefit-card\"\u003e\n\n        \u003ch3\u003e\n          Fully Incinerable Construction\n        \u003c\/h3\u003e\n\n        \u003cp\u003e\n          Non-metallic filter construction supports simplified end-of-life\n          disposal in facilities where incineration is required or preferred.\n        \u003c\/p\u003e\n\n      \u003c\/article\u003e\n\n    \u003c\/div\u003e\n\n  \u003c\/section\u003e\n\n\n  \u003c!-- =========================================================\n       TECHNICAL SPECIFICATIONS\n       ========================================================= --\u003e\n\n  \u003csection class=\"product-section\" aria-labelledby=\"specifications-heading\"\u003e\n\n    \u003ch2 id=\"specifications-heading\"\u003e\n      Technical Specifications\n    \u003c\/h2\u003e\n\n    \u003cdiv class=\"specifications-table-wrapper\"\u003e\n\n      \u003ctable class=\"specifications-table\"\u003e\n\n        \u003ctbody\u003e\n\n          \u003ctr\u003e\n            \u003cth scope=\"row\"\u003e\n              Filter Type\n            \u003c\/th\u003e\n\n            \u003ctd\u003e\n              V-Bank Rigid Box Filter\n            \u003c\/td\u003e\n          \u003c\/tr\u003e\n\n\n          \u003ctr\u003e\n            \u003cth scope=\"row\"\u003e\n              Filter Design\n            \u003c\/th\u003e\n\n            \u003ctd\u003e\n              Mini-Pleat V-Bank Configuration\n            \u003c\/td\u003e\n          \u003c\/tr\u003e\n\n\n          \u003ctr\u003e\n            \u003cth scope=\"row\"\u003e\n              MERV Efficiency\n            \u003c\/th\u003e\n\n            \u003ctd\u003e\n              MERV 11 \/ MERV 14 \/ MERV 15\n            \u003c\/td\u003e\n          \u003c\/tr\u003e\n\n\n          \u003ctr\u003e\n            \u003cth scope=\"row\"\u003e\n              EN 779 Grades\n            \u003c\/th\u003e\n\n            \u003ctd\u003e\n              M6 \/ F8 \/ F9\n            \u003c\/td\u003e\n          \u003c\/tr\u003e\n\n\n          \u003ctr\u003e\n            \u003cth scope=\"row\"\u003e\n              Filtration Standard\n            \u003c\/th\u003e\n\n            \u003ctd\u003e\n              ASHRAE 52.2\n            \u003c\/td\u003e\n          \u003c\/tr\u003e\n\n\n          \u003ctr\u003e\n            \u003cth scope=\"row\"\u003e\n              Filter Media\n            \u003c\/th\u003e\n\n            \u003ctd\u003e\n              Synthetic Glass Fiber Media\n            \u003c\/td\u003e\n          \u003c\/tr\u003e\n\n\n          \u003ctr\u003e\n            \u003cth scope=\"row\"\u003e\n              Media Bonding\n            \u003c\/th\u003e\n\n            \u003ctd\u003e\n              Polyurethane Potting\n            \u003c\/td\u003e\n          \u003c\/tr\u003e\n\n\n          \u003ctr\u003e\n            \u003cth scope=\"row\"\u003e\n              Media Separator\n            \u003c\/th\u003e\n\n            \u003ctd\u003e\n              Thermoplastic Bead Separators (Hot Melt Beads)\n            \u003c\/td\u003e\n          \u003c\/tr\u003e\n\n\n          \u003ctr\u003e\n            \u003cth scope=\"row\"\u003e\n              Frame Material\n            \u003c\/th\u003e\n\n            \u003ctd\u003e\n              ABS Plastic — Non-Metallic\n            \u003c\/td\u003e\n          \u003c\/tr\u003e\n\n\n          \u003ctr\u003e\n            \u003cth scope=\"row\"\u003e\n              Header Construction\n            \u003c\/th\u003e\n\n            \u003ctd\u003e\n              20 mm Header\n            \u003c\/td\u003e\n          \u003c\/tr\u003e\n\n\n          \u003ctr\u003e\n            \u003cth scope=\"row\"\u003e\n              Maximum Operating Velocity\n            \u003c\/th\u003e\n\n            \u003ctd\u003e\n              625 fpm \/ 3.175 m\/s\n            \u003c\/td\u003e\n          \u003c\/tr\u003e\n\n\n          \u003ctr\u003e\n            \u003cth scope=\"row\"\u003e\n              Maximum Operating Temperature\n            \u003c\/th\u003e\n\n            \u003ctd\u003e\n              176°F (80°C)\n            \u003c\/td\u003e\n          \u003c\/tr\u003e\n\n\n          \u003ctr\u003e\n            \u003cth scope=\"row\"\u003e\n              Final Pressure Drop\n            \u003c\/th\u003e\n\n            \u003ctd\u003e\n              1.50\" w.g.\n            \u003c\/td\u003e\n          \u003c\/tr\u003e\n\n\n          \u003ctr\u003e\n            \u003cth scope=\"row\"\u003e\n              Maximum Recommended Pressure Drop\n            \u003c\/th\u003e\n\n            \u003ctd\u003e\n              2.00\" w.g.\n            \u003c\/td\u003e\n          \u003c\/tr\u003e\n\n\n          \u003ctr\u003e\n            \u003cth scope=\"row\"\u003e\n              Disposal\n            \u003c\/th\u003e\n\n            \u003ctd\u003e\n              Fully Incinerable, Non-Metallic Construction\n            \u003c\/td\u003e\n          \u003c\/tr\u003e\n\u003ctr\u003e\n            \u003cth scope=\"row\"\u003e\n              Fire Classification\n            \u003c\/th\u003e\n\n            \u003ctd\u003e\n              UL900 Classified\n            \u003c\/td\u003e\n        \u003c\/tr\u003e\n\u003c\/tbody\u003e\n\n      \u003c\/table\u003e\n\n    \u003c\/div\u003e\n\n  \u003c\/section\u003e\n\n\n  \u003c!-- =========================================================\n       MICROGLASS PERFORMANCE\n       ========================================================= --\u003e\n\n  \u003csection class=\"product-section\" aria-labelledby=\"microglass-performance-heading\"\u003e\n\n    \u003ch2 id=\"microglass-performance-heading\"\u003e\n      Glass Fiber Media \u0026amp; Mini-Pleat Performance\n    \u003c\/h2\u003e\n\n    \u003cp\u003e\n      The V-Bank Microglass Filter uses\n      \u003cstrong\u003esynthetic glass fiber media\u003c\/strong\u003e arranged in a mini-pleat\n      configuration to provide a large effective filtration area within\n      a compact rigid filter design. The increased media area helps distribute\n      airflow across the filter while supporting the selected MERV efficiency.\n    \u003c\/p\u003e\n\n    \u003cp\u003e\n      Polyurethane potting secures the media pack within the frame and provides\n      enhanced burst resistance for demanding airflow applications. The\n      combination of mini-pleat geometry, rigid V-bank construction, and\n      potted media is intended to provide consistent filter performance in\n      compatible HVAC systems.\n    \u003c\/p\u003e\n\n    \u003cdiv class=\"carbon-callout\"\u003e\n\n      \u003cdiv class=\"carbon-callout-icon\" aria-hidden=\"true\"\u003e\n        🔬\n      \u003c\/div\u003e\n\n      \u003cdiv class=\"carbon-callout-body\"\u003e\n\n        \u003cstrong\u003e\n          High-Strength Glass Fiber Media\n        \u003c\/strong\u003e\n\n        \u003cp\u003e\n          Synthetic glass fiber media combined with polyurethane potting\n          provides a rigid, durable media pack designed for high-airflow\n          HVAC applications and demanding installation environments.\n        \u003c\/p\u003e\n\n      \u003c\/div\u003e\n\n    \u003c\/div\u003e\n\n  \u003c\/section\u003e\n\n\n  \u003c!-- =========================================================\n       FILTER GRADE SELECTION\n       ========================================================= --\u003e\n\n  \u003csection class=\"product-section\" aria-labelledby=\"merv-selection-heading\"\u003e\n\n    \u003ch2 id=\"merv-selection-heading\"\u003e\n      Choosing the Right MERV Rating\n    \u003c\/h2\u003e\n\n    \u003cp\u003e\n      Select the appropriate MERV efficiency based on the required particulate\n      filtration level, facility application, airflow requirements, and HVAC\n      system pressure-drop limitations.\n    \u003c\/p\u003e\n\n    \u003cdiv class=\"merv-selection-grid\"\u003e\n\n      \u003carticle class=\"merv-selection-card\"\u003e\n\n        \u003ch3\u003e\n          MERV 11\n        \u003c\/h3\u003e\n\n        \u003cp\u003e\n          Suitable for general commercial ventilation and HVAC applications\n          requiring enhanced particulate filtration.\n        \u003c\/p\u003e\n\n      \u003c\/article\u003e\n\n\n      \u003carticle class=\"merv-selection-card\"\u003e\n\n        \u003ch3\u003e\n          MERV 13\n        \u003c\/h3\u003e\n\n        \u003cp\u003e\n          Provides higher-efficiency particulate filtration for offices,\n          hotels, light healthcare, and commercial HVAC applications.\n        \u003c\/p\u003e\n\n      \u003c\/article\u003e\n\n\n      \u003carticle class=\"merv-selection-card\"\u003e\n\n        \u003ch3\u003e\n          MERV 14\n        \u003c\/h3\u003e\n\n        \u003cp\u003e\n          Higher-efficiency filtration for hospitals, laboratories, LEED\n          buildings, and other applications requiring increased particulate\n          control.\n        \u003c\/p\u003e\n\n      \u003c\/article\u003e\n\n\n      \u003carticle class=\"merv-selection-card\"\u003e\n\n        \u003ch3\u003e\n          MERV 15\n        \u003c\/h3\u003e\n\n        \u003cp\u003e\n          High-efficiency particulate filtration for demanding applications\n          including pharmaceutical, controlled-environment, and critical\n          HVAC systems.\n        \u003c\/p\u003e\n\n      \u003c\/article\u003e\n\n    \u003c\/div\u003e\n\n  \u003c\/section\u003e\n\n\n  \u003c!-- =========================================================\n       V-BANK DESIGN\n       ========================================================= --\u003e\n\n  \u003csection class=\"product-section\" aria-labelledby=\"vbank-design-heading\"\u003e\n\n    \u003ch2 id=\"vbank-design-heading\"\u003e\n      V-Bank Mini-Pleat Design for High Airflow\n    \u003c\/h2\u003e\n\n    \u003cp\u003e\n      The V-bank configuration arranges multiple angled media sections within\n      the rigid filter frame, increasing the effective filtration surface area\n      compared with a flat filter occupying the same general footprint.\n      The mini-pleat construction allows a large amount of filtration media\n      to be incorporated into a compact filter design.\n    \u003c\/p\u003e\n\n    \u003cp\u003e\n      This extended-surface configuration is designed to support\n      \u003cstrong\u003ehigh airflow and low resistance\u003c\/strong\u003e while maintaining the\n      structural advantages of a rigid box-style filter. The maximum\n      recommended operating velocity is \u003cstrong\u003e625 fpm (3.175 m\/s)\u003c\/strong\u003e.\n    \u003c\/p\u003e\n\n  \u003c\/section\u003e\n\n\n  \u003c!-- =========================================================\n       FILTER GRADE TIER PANEL\n       ========================================================= --\u003e\n\n  \u003csection class=\"product-section\" aria-labelledby=\"grade-tiers-heading\"\u003e\n\n    \u003ch2 id=\"grade-tiers-heading\"\u003e\n      MERV \u0026amp; EN 779 Filter Grade Tiers\n    \u003c\/h2\u003e\n\n    \u003cdiv class=\"grade-grid\" role=\"list\" aria-label=\"Available filter grade tiers\"\u003e\n\n      \u003carticle class=\"grade-tier grade-tier-m6\" role=\"listitem\"\u003e\n\n        \u003cspan class=\"grade-en\"\u003e\n          EN 779: M6\n        \u003c\/span\u003e\n\n        \u003cspan class=\"grade-merv\"\u003e\n          MERV 11\n        \u003c\/span\u003e\n\n        \u003cspan class=\"grade-label\"\u003e\n          General commercial ventilation\n        \u003c\/span\u003e\n\n      \u003c\/article\u003e\n\n\n      \u003carticle class=\"grade-tier grade-tier-f7\" role=\"listitem\"\u003e\n\n        \u003cspan class=\"grade-en\"\u003e\n          EN 779: F7\n        \u003c\/span\u003e\n\n        \u003cspan class=\"grade-merv\"\u003e\n          MERV 13\n        \u003c\/span\u003e\n\n        \u003cspan class=\"grade-label\"\u003e\n          Offices, hotels \u0026amp; light healthcare\n        \u003c\/span\u003e\n\n      \u003c\/article\u003e\n\n\n      \u003carticle class=\"grade-tier grade-tier-f8\" role=\"listitem\"\u003e\n\n        \u003cspan class=\"grade-en\"\u003e\n          EN 779: F8\n        \u003c\/span\u003e\n\n        \u003cspan class=\"grade-merv\"\u003e\n          MERV 14\n        \u003c\/span\u003e\n\n        \u003cspan class=\"grade-label\"\u003e\n          Hospitals, laboratories \u0026amp; LEED buildings\n        \u003c\/span\u003e\n\n      \u003c\/article\u003e\n\n\n      \u003carticle class=\"grade-tier grade-tier-f9\" role=\"listitem\"\u003e\n\n        \u003cspan class=\"grade-en\"\u003e\n          EN 779: F9\n        \u003c\/span\u003e\n\n        \u003cspan class=\"grade-merv\"\u003e\n          MERV 15\n        \u003c\/span\u003e\n\n        \u003cspan class=\"grade-label\"\u003e\n          Pharmaceutical, cleanroom \u0026amp; critical applications\n        \u003c\/span\u003e\n\n      \u003c\/article\u003e\n\n    \u003c\/div\u003e\n\n  \u003c\/section\u003e\n\n\n  \u003c!-- =========================================================\n       FRAME \u0026 HEADER\n       ========================================================= --\u003e\n\n  \u003csection class=\"product-section\" aria-labelledby=\"frame-heading\"\u003e\n\n    \u003ch2 id=\"frame-heading\"\u003e\n      ABS Frame \u0026amp; 20 mm Header Construction\n    \u003c\/h2\u003e\n\n    \u003cp\u003e\n      The V-Bank Microglass Filter uses a\n      \u003cstrong\u003enon-metallic ABS plastic frame\u003c\/strong\u003e with a 20 mm header.\n      The rigid frame provides structural support for the mini-pleat media\n      pack while maintaining the compact V-bank configuration.\n    \u003c\/p\u003e\n\n    \u003cp\u003e\n      The non-metallic construction contributes to the filter's\n      \u003cstrong\u003efully incinerable design\u003c\/strong\u003e, allowing the filter to be\n      considered for applications where simplified disposal is important.\n    \u003c\/p\u003e\n\n    \u003cp\u003e\n      Always verify the existing HVAC housing, filter bank dimensions, header\n      configuration, sealing arrangement, and installation requirements\n      before ordering a replacement filter.\n    \u003c\/p\u003e\n\n  \u003c\/section\u003e\n\n\n  \u003c!-- =========================================================\n       DISPOSAL \/ INCINERATION\n       ========================================================= --\u003e\n\n  \u003csection class=\"product-section\" aria-labelledby=\"disposal-heading\"\u003e\n\n    \u003ch2 id=\"disposal-heading\"\u003e\n      Fully Incinerable Non-Metallic Construction\n    \u003c\/h2\u003e\n\n    \u003cp\u003e\n      The V-Bank Microglass Filter is constructed without conventional\n      metallic separators, using a non-metallic ABS frame and thermoplastic\n      bead separators. This construction is designed to allow the complete\n      filter assembly to be incinerated without requiring separation of\n      metallic filter components.\n    \u003c\/p\u003e\n\n    \u003cp\u003e\n      Fully incinerable construction can simplify end-of-life handling for\n      facilities where spent filters require controlled disposal, including\n      compatible pharmaceutical, healthcare, food processing, and other\n      specialized environments.\n    \u003c\/p\u003e\n\n  \u003c\/section\u003e\n\n\n  \u003c!-- =========================================================\n       INDUSTRY APPLICATIONS\n       ========================================================= --\u003e\n\n  \u003csection class=\"product-section\" aria-labelledby=\"applications-heading\"\u003e\n\n    \u003ch2 id=\"applications-heading\"\u003e\n      Commercial \u0026amp; Industrial HVAC Applications\n    \u003c\/h2\u003e\n\n    \u003cp\u003e\n      AccuraFil V-Bank Microglass Filters are designed for applications\n      requiring high-efficiency particulate filtration, extended media\n      surface area, and a compact rigid V-bank configuration, including:\n    \u003c\/p\u003e\n\n    \u003cul class=\"application-list\"\u003e\n\n      \u003cli\u003e\n        Hospitals and healthcare facilities\n      \u003c\/li\u003e\n\n      \u003cli\u003e\n        Pharmaceutical and biotechnology facilities\n      \u003c\/li\u003e\n\n      \u003cli\u003e\n        ISO cleanroom and controlled environments\n      \u003c\/li\u003e\n\n      \u003cli\u003e\n        Commercial office buildings\n      \u003c\/li\u003e\n\n      \u003cli\u003e\n        Data centers and mission-critical facilities\n      \u003c\/li\u003e\n\n      \u003cli\u003e\n        Food and beverage processing facilities\n      \u003c\/li\u003e\n\n      \u003cli\u003e\n        Air handling units and packaged HVAC systems\n      \u003c\/li\u003e\n\n      \u003cli\u003e\n        Variable Air Volume (VAV) systems\n      \u003c\/li\u003e\n\n      \u003cli\u003e\n        Built-up filter banks and multi-cell filtration systems\n      \u003c\/li\u003e\n\n      \u003cli\u003e\n        Industrial HVAC applications requiring compact high-efficiency filtration\n      \u003c\/li\u003e\n\n    \u003c\/ul\u003e\n\n  \u003c\/section\u003e\n\n\n  \u003c!-- =========================================================\n       HIGH-DEMAND ENVIRONMENTS\n       ========================================================= --\u003e\n\n  \u003csection class=\"product-section\" aria-labelledby=\"high-demand-heading\"\u003e\n\n    \u003ch2 id=\"high-demand-heading\"\u003e\n      Reliable Performance in High-Demand Environments\n    \u003c\/h2\u003e\n\n    \u003cp\u003e\n      The rigid V-bank construction, glass fiber media, and polyurethane-potted\n      media pack make this filter suitable for HVAC applications requiring\n      consistent particulate filtration under demanding airflow conditions.\n    \u003c\/p\u003e\n\n\n    \u003ch3\u003e\n      Hospitals \u0026amp; Healthcare\n    \u003c\/h3\u003e\n\n    \u003cp\u003e\n      Higher-efficiency MERV configurations provide particulate filtration\n      for compatible healthcare HVAC applications. The fully incinerable\n      construction can also simplify disposal of spent filters where\n      controlled disposal procedures are required.\n    \u003c\/p\u003e\n\n\n    \u003ch3\u003e\n      Pharmaceutical \u0026amp; Cleanroom Applications\n    \u003c\/h3\u003e\n\n    \u003cp\u003e\n      MERV 14 and MERV 15 configurations provide high-efficiency particulate\n      filtration for compatible controlled environments. Non-metallic,\n      incinerable construction can support facilities where filter disposal\n      procedures are an important consideration.\n    \u003c\/p\u003e\n\n\n    \u003ch3\u003e\n      Commercial \u0026amp; Office Buildings\n    \u003c\/h3\u003e\n\n    \u003cp\u003e\n      MERV 11 through MERV 14 configurations provide a range of particulate\n      filtration options for commercial HVAC systems where efficient airflow\n      and compact filter construction are important.\n    \u003c\/p\u003e\n\n\n    \u003ch3\u003e\n      VAV \u0026amp; Air Handling Systems\n    \u003c\/h3\u003e\n\n    \u003cp\u003e\n      The rigid V-bank construction and polyurethane-potted media pack are\n      designed for demanding air handler and variable-airflow applications\n      where maintaining structural integrity is important.\n    \u003c\/p\u003e\n\n\n    \u003ch3\u003e\n      Food Processing Facilities\n    \u003c\/h3\u003e\n\n    \u003cp\u003e\n      Non-metallic and fully incinerable construction can be advantageous\n      for compatible food-processing HVAC applications where simplified\n      end-of-life disposal is important.\n    \u003c\/p\u003e\n\n  \u003c\/section\u003e\n\n\n  \u003c!-- =========================================================\n       DUAL PERFORMANCE\n       ========================================================= --\u003e\n\n  \u003csection class=\"product-section\" aria-labelledby=\"performance-heading\"\u003e\n\n    \u003ch2 id=\"performance-heading\"\u003e\n      High-Efficiency Particulate Filtration Performance\n    \u003c\/h2\u003e\n\n    \u003cdiv class=\"benefits-grid\"\u003e\n\n      \u003carticle class=\"benefit-card\"\u003e\n\n        \u003ch3\u003e\n          High-Efficiency Particle Capture\n        \u003c\/h3\u003e\n\n        \u003cp\u003e\n          Available from MERV 11 through MERV 15 to accommodate different\n          particulate filtration requirements.\n        \u003c\/p\u003e\n\n      \u003c\/article\u003e\n\n\n      \u003carticle class=\"benefit-card\"\u003e\n\n        \u003ch3\u003e\n          Large Effective Media Area\n        \u003c\/h3\u003e\n\n        \u003cp\u003e\n          Mini-pleat V-bank geometry increases effective media surface area\n          within a compact rigid filter configuration.\n        \u003c\/p\u003e\n\n      \u003c\/article\u003e\n\n\n      \u003carticle class=\"benefit-card\"\u003e\n\n        \u003ch3\u003e\n          Enhanced Media Integrity\n        \u003c\/h3\u003e\n\n        \u003cp\u003e\n          Polyurethane potting secures the glass fiber media pack within\n          the frame and provides enhanced burst resistance.\n        \u003c\/p\u003e\n\n      \u003c\/article\u003e\n\n\n      \u003carticle class=\"benefit-card\"\u003e\n\n        \u003ch3\u003e\n          Simplified Disposal\n        \u003c\/h3\u003e\n\n        \u003cp\u003e\n          Non-metallic construction and thermoplastic bead separators support\n          fully incinerable filter disposal without component separation.\n        \u003c\/p\u003e\n\n      \u003c\/article\u003e\n\n    \u003c\/div\u003e\n\n  \u003c\/section\u003e\n\n\n  \u003c!-- =========================================================\n       SELECTION GUIDE\n       ========================================================= --\u003e\n\n  \u003csection class=\"product-section\" aria-labelledby=\"selection-guide-heading\"\u003e\n\n    \u003ch2 id=\"selection-guide-heading\"\u003e\n      How to Select the Right V-Bank Microglass Filter\n    \u003c\/h2\u003e\n\n    \u003col class=\"howto-steps\"\u003e\n\n      \u003cli class=\"howto-step\"\u003e\n\n        \u003cspan class=\"step-number\" aria-hidden=\"true\"\u003e\n          1\n        \u003c\/span\u003e\n\n        \u003cdiv class=\"step-content\"\u003e\n\n          \u003ch3\u003e\n            Select the Required MERV Rating\n          \u003c\/h3\u003e\n\n          \u003cp\u003e\n            Choose MERV 11 for general commercial ventilation. Choose\n            MERV 13 for offices, hotels, and light healthcare applications.\n            Choose MERV 14 for hospitals, laboratories, and higher-efficiency\n            HVAC applications. Choose MERV 15 for pharmaceutical, cleanroom,\n            and other critical environments requiring high-efficiency\n            particulate filtration.\n          \u003c\/p\u003e\n\n        \u003c\/div\u003e\n\n      \u003c\/li\u003e\n\n\n      \u003cli class=\"howto-step\"\u003e\n\n        \u003cspan class=\"step-number\" aria-hidden=\"true\"\u003e\n          2\n        \u003c\/span\u003e\n\n        \u003cdiv class=\"step-content\"\u003e\n\n          \u003ch3\u003e\n            Verify Airflow \u0026amp; Pressure-Drop Requirements\n          \u003c\/h3\u003e\n\n          \u003cp\u003e\n            Confirm that system airflow does not exceed the specified maximum\n            operating velocity of \u003cstrong\u003e625 fpm \/ 3.175 m\/s\u003c\/strong\u003e.\n            Verify that the HVAC system can accommodate the specified\n            pressure-drop conditions, including the 1.50\" w.g. final\n            pressure drop and 2.00\" w.g. maximum recommended pressure drop.\n          \u003c\/p\u003e\n\n        \u003c\/div\u003e\n\n      \u003c\/li\u003e\n\n\n      \u003cli class=\"howto-step\"\u003e\n\n        \u003cspan class=\"step-number\" aria-hidden=\"true\"\u003e\n          3\n        \u003c\/span\u003e\n\n        \u003cdiv class=\"step-content\"\u003e\n\n          \u003ch3\u003e\n            Confirm Housing Compatibility\n          \u003c\/h3\u003e\n\n          \u003cp\u003e\n            Verify the actual filter face dimensions, housing depth,\n            header configuration, sealing arrangement, and installation\n            orientation before ordering. The specified configuration uses\n            an ABS plastic frame with a 20 mm header.\n          \u003c\/p\u003e\n\n        \u003c\/div\u003e\n\n      \u003c\/li\u003e\n\n\n      \u003cli class=\"howto-step\"\u003e\n\n        \u003cspan class=\"step-number\" aria-hidden=\"true\"\u003e\n          4\n        \u003c\/span\u003e\n\n        \u003cdiv class=\"step-content\"\u003e\n\n          \u003ch3\u003e\n            Confirm Temperature \u0026amp; Disposal Requirements\n          \u003c\/h3\u003e\n\n          \u003cp\u003e\n            Confirm that operating temperature does not exceed\n            \u003cstrong\u003e176°F (80°C)\u003c\/strong\u003e. Where filter incineration is\n            required or preferred, verify that the facility's disposal\n            procedures are compatible with fully incinerable filter\n            construction.\n          \u003c\/p\u003e\n\n        \u003c\/div\u003e\n\n      \u003c\/li\u003e\n\n    \u003c\/ol\u003e\n\n  \u003c\/section\u003e\n\n\n  \u003c!-- =========================================================\n       PRODUCT COMPARISON\n       ========================================================= --\u003e\n\n  \u003csection class=\"product-section\" aria-labelledby=\"comparison-heading\"\u003e\n\n    \u003ch2 id=\"comparison-heading\"\u003e\n      V-Bank Microglass Filter vs. Bag \u0026amp; Standard Box Filters\n    \u003c\/h2\u003e\n\n    \u003cp\u003e\n      Compared with conventional \u003cstrong\u003ebag-style filters\u003c\/strong\u003e, the\n      rigid V-bank design provides a fixed filter geometry rather than a\n      flexible pocket configuration. The mini-pleat glass fiber construction\n      provides a large effective media area within the rigid housing format,\n      making the design suitable for systems where compact construction and\n      high airflow are important.\n    \u003c\/p\u003e\n\n    \u003cp\u003e\n      Compared with conventional\n      \u003cstrong\u003estandard box-type pleated filters\u003c\/strong\u003e, the V-bank\n      configuration allows more effective media area to be incorporated\n      within the filter footprint. The polyurethane-potted media pack and\n      thermoplastic bead separators also provide structural support for the\n      pleated media during operation.\n    \u003c\/p\u003e\n\n    \u003cp\u003e\n      The best filter configuration depends on required MERV efficiency,\n      airflow, available installation depth, pressure-drop limitations,\n      housing dimensions, and facility disposal requirements.\n    \u003c\/p\u003e\n\n  \u003c\/section\u003e\n\n\n  \u003c!-- =========================================================\n       PRODUCT SELECTION \u0026 PROCUREMENT\n       ========================================================= --\u003e\n\n  \u003csection class=\"product-section procurement-section\" aria-labelledby=\"procurement-heading\"\u003e\n\n    \u003ch2 id=\"procurement-heading\"\u003e\n      Product Selection \u0026amp; Procurement\n    \u003c\/h2\u003e\n\n    \u003cp\u003e\n      Before ordering a replacement V-Bank Microglass Filter, verify the\n      \u003cstrong\u003eactual filter dimensions\u003c\/strong\u003e, required MERV rating,\n      filter depth, frame and header configuration, airflow requirements,\n      maximum operating velocity, pressure-drop limitations, and compatibility\n      with the existing HVAC housing or filter bank.\n    \u003c\/p\u003e\n\n    \u003cp\u003e\n      Do not select a replacement filter based only on the nominal size printed\n      on an existing filter. Confirm the physical dimensions and housing\n      configuration to reduce the risk of installation problems, poor fit,\n      inadequate sealing, return shipping expenses, restocking charges,\n      and project delays.\n    \u003c\/p\u003e\n\n    \u003cp\u003e\n      AccuraFil supplies commercial and industrial air filtration products\n      for facility managers, HVAC contractors, mechanical engineers,\n      healthcare organizations, pharmaceutical facilities, data center\n      operators, and procurement teams.\n    \u003c\/p\u003e\n\n  \u003c\/section\u003e\n\n\n  \u003c!-- =========================================================\n       FAQ\n       ========================================================= --\u003e\n\n  \u003csection class=\"product-section\" aria-labelledby=\"faq-heading\"\u003e\n\n    \u003ch2 id=\"faq-heading\"\u003e\n      Frequently Asked Questions\n    \u003c\/h2\u003e\n\n\n    \u003cdetails class=\"faq-item\"\u003e\n\n      \u003csummary\u003e\n        What is a V-Bank Microglass Filter?\n      \u003c\/summary\u003e\n\n      \u003cdiv class=\"faq-answer\"\u003e\n\n        \u003cp\u003e\n          A V-Bank Microglass Filter is a rigid box-style HVAC filter that\n          uses glass fiber media arranged in a V-shaped mini-pleat\n          configuration. The design increases effective media surface area\n          within a compact filter footprint and is intended for high-efficiency\n          particulate filtration applications.\n        \u003c\/p\u003e\n\n      \u003c\/div\u003e\n\n    \u003c\/details\u003e\n\n\n    \u003cdetails class=\"faq-item\"\u003e\n\n      \u003csummary\u003e\n        What MERV ratings are available?\n      \u003c\/summary\u003e\n\n      \u003cdiv class=\"faq-answer\"\u003e\n\n        \u003cp\u003e\n          The AccuraFil V-Bank Microglass Filter is available in\n          \u003cstrong\u003eMERV 11, MERV 13, MERV 14, and MERV 15\u003c\/strong\u003e according\n          to the supplied product specifications. These correspond to\n          M6, F7, F8, and F9 classifications under EN 779.\n        \u003c\/p\u003e\n\n      \u003c\/div\u003e\n\n    \u003c\/details\u003e\n\n\n    \u003cdetails class=\"faq-item\"\u003e\n\n      \u003csummary\u003e\n        What type of filter media does it use?\n      \u003c\/summary\u003e\n\n      \u003cdiv class=\"faq-answer\"\u003e\n\n        \u003cp\u003e\n          The filter uses synthetic glass fiber media. The media pack is\n          secured using polyurethane potting and incorporates thermoplastic\n          bead separators to maintain pleat spacing.\n        \u003c\/p\u003e\n\n      \u003c\/div\u003e\n\n    \u003c\/details\u003e\n\n\n    \u003cdetails class=\"faq-item\"\u003e\n\n      \u003csummary\u003e\n        What is the advantage of the mini-pleat V-bank design?\n      \u003c\/summary\u003e\n\n      \u003cdiv class=\"faq-answer\"\u003e\n\n        \u003cp\u003e\n          The mini-pleat V-bank configuration increases effective media\n          surface area within a compact rigid filter footprint. This design\n          is intended to support high airflow and efficient particulate\n          filtration while maintaining a rigid filter structure.\n        \u003c\/p\u003e\n\n      \u003c\/div\u003e\n\n    \u003c\/details\u003e\n\n\n    \u003cdetails class=\"faq-item\"\u003e\n\n      \u003csummary\u003e\n        What are thermoplastic bead separators?\n      \u003c\/summary\u003e\n\n      \u003cdiv class=\"faq-answer\"\u003e\n\n        \u003cp\u003e\n          Thermoplastic bead separators, also called hot melt beads, are\n          non-metallic separator elements used to maintain consistent pleat\n          spacing throughout the media pack.\n        \u003c\/p\u003e\n\n      \u003c\/div\u003e\n\n    \u003c\/details\u003e\n\n\n    \u003cdetails class=\"faq-item\"\u003e\n\n      \u003csummary\u003e\n        Is the V-Bank Microglass Filter fully incinerable?\n      \u003c\/summary\u003e\n\n      \u003cdiv class=\"faq-answer\"\u003e\n\n        \u003cp\u003e\n          The supplied product specifications identify the filter as\n          \u003cstrong\u003efully incinerable and non-metallic\u003c\/strong\u003e. This\n          construction is designed to simplify end-of-life disposal where\n          facility procedures call for filter incineration.\n        \u003c\/p\u003e\n\n      \u003c\/div\u003e\n\n    \u003c\/details\u003e\n\n\n    \u003cdetails class=\"faq-item\"\u003e\n\n      \u003csummary\u003e\n        What is the maximum operating velocity?\n      \u003c\/summary\u003e\n\n      \u003cdiv class=\"faq-answer\"\u003e\n\n        \u003cp\u003e\n          The specified maximum operating velocity is\n          \u003cstrong\u003e625 fpm (3.175 m\/s)\u003c\/strong\u003e. HVAC system operating\n          conditions should be verified before installation.\n        \u003c\/p\u003e\n\n      \u003c\/div\u003e\n\n    \u003c\/details\u003e\n\n\n    \u003cdetails class=\"faq-item\"\u003e\n\n      \u003csummary\u003e\n        What is the maximum operating temperature?\n      \u003c\/summary\u003e\n\n      \u003cdiv class=\"faq-answer\"\u003e\n\n        \u003cp\u003e\n          The specified maximum operating temperature is\n          \u003cstrong\u003e176°F (80°C)\u003c\/strong\u003e.\n        \u003c\/p\u003e\n\n      \u003c\/div\u003e\n\n    \u003c\/details\u003e\n\n\n    \u003cdetails class=\"faq-item\"\u003e\n\n      \u003csummary\u003e\n        What frame and header does the filter use?\n      \u003c\/summary\u003e\n\n      \u003cdiv class=\"faq-answer\"\u003e\n\n        \u003cp\u003e\n          The specified configuration uses a\n          \u003cstrong\u003enon-metallic ABS plastic frame with a 20 mm header\u003c\/strong\u003e.\n          Housing compatibility should be verified before ordering.\n        \u003c\/p\u003e\n\n      \u003c\/div\u003e\n\n    \u003c\/details\u003e\n\n\n    \u003cdetails class=\"faq-item\"\u003e\n\n      \u003csummary\u003e\n        What should I verify before ordering a replacement?\n      \u003c\/summary\u003e\n\n      \u003cdiv class=\"faq-answer\"\u003e\n\n        \u003cp\u003e\n          Verify the actual filter dimensions, MERV rating, filter depth,\n          frame and header configuration, housing dimensions, sealing\n          arrangement, airflow requirements, and pressure-drop limitations.\n          Matching the physical filter and housing configuration helps avoid\n          fit problems, return shipping charges, restocking fees, and delays.\n        \u003c\/p\u003e\n\n      \u003c\/div\u003e\n\n    \u003c\/details\u003e\n\n\n  \u003c\/section\u003e\n\n\n  \u003c!-- =========================================================\n       FINAL PRODUCT STATEMENT\n       ========================================================= --\u003e\n\n  \u003csection class=\"product-final\"\u003e\n\n    \u003ch2\u003e\n      AccuraFil V-Bank Microglass Air Filters\n    \u003c\/h2\u003e\n\n    \u003cp\u003e\n      AccuraFil V-Bank Microglass Air Filters combine\n      \u003cstrong\u003esynthetic glass fiber media, mini-pleat V-bank construction,\n      polyurethane potting, thermoplastic bead separators, and a non-metallic\n      ABS frame\u003c\/strong\u003e to provide high-efficiency particulate filtration\n      for commercial, healthcare, pharmaceutical, industrial, VAV, air\n      handler, and built-up filter bank applications. Available in\n      MERV 11 through MERV 15 configurations with fully incinerable\n      construction for compatible disposal requirements.\n    \u003c\/p\u003e\n\n  \u003c\/section\u003e\n\n\u003c\/div\u003e\n\n\n\u003cstyle\u003e\n\n  .accurafil-product-description {\n    max-width: 1200px;\n    margin: 0 auto;\n    color: #2d3748;\n    line-height: 1.7;\n    font-size: 16px;\n  }\n\n\n  .accurafil-product-description h2 {\n    color: #007b8c;\n    font-size: 30px;\n    line-height: 1.25;\n    margin: 0 0 20px;\n  }\n\n\n  .accurafil-product-description h3 {\n    color: #0f4c5c;\n    font-size: 20px;\n    line-height: 1.35;\n    margin: 0 0 10px;\n  }\n\n\n  .product-intro {\n    background: #f0fdfa;\n    border-left: 5px solid #00ced3;\n    padding: 30px;\n    margin-bottom: 35px;\n    border-radius: 10px;\n  }\n\n\n  .product-eyebrow {\n    color: #007b8c;\n    font-size: 13px;\n    font-weight: 700;\n    letter-spacing: .08em;\n    text-transform: uppercase;\n    margin: 0 0 10px;\n  }\n\n\n  .product-intro p {\n    margin: 0 0 15px;\n  }\n\n\n  .product-intro p:last-child {\n    margin-bottom: 0;\n  }\n\n\n  .product-section {\n    background: #ffffff;\n    padding: 30px;\n    margin-bottom: 30px;\n    border-radius: 14px;\n    box-shadow: 0 8px 24px rgba(0, 0, 0, .06);\n  }\n\n\n  .product-section p {\n    margin: 0 0 15px;\n  }\n\n\n  .product-section p:last-child {\n    margin-bottom: 0;\n  }\n\n\n  .benefits-grid {\n    display: grid;\n    grid-template-columns: repeat(2, minmax(0, 1fr));\n    gap: 20px;\n  }\n\n\n  .benefit-card,\n  .merv-selection-card {\n    background: #f8fafc;\n    border: 1px solid #edf2f7;\n    border-radius: 10px;\n    padding: 22px;\n  }\n\n\n  .benefit-card p,\n  .merv-selection-card p {\n    margin: 0;\n    color: #4a5568;\n  }\n\n\n  .merv-selection-grid {\n    display: grid;\n    grid-template-columns: repeat(4, minmax(0, 1fr));\n    gap: 20px;\n    margin-top: 22px;\n  }\n\n\n  .merv-selection-card h3 {\n    color: #007b8c;\n  }\n\n\n  .carbon-callout {\n    display: flex;\n    align-items: flex-start;\n    gap: 20px;\n    background: linear-gradient(135deg, #1e293b 0%, #0f172a 100%);\n    border-radius: 10px;\n    padding: 24px;\n    margin-top: 24px;\n    color: #e2e8f0;\n  }\n\n\n  .carbon-callout-icon {\n    flex-shrink: 0;\n    width: 54px;\n    height: 54px;\n    background: #97e6e6;\n    border-radius: 10px;\n    display: flex;\n    align-items: center;\n    justify-content: center;\n    font-size: 26px;\n  }\n\n\n  .carbon-callout-body strong {\n    display: block;\n    font-size: 16px;\n    font-weight: 700;\n    color: #97e6e6;\n    margin-bottom: 6px;\n    text-transform: uppercase;\n    letter-spacing: .09em;\n  }\n\n\n  .carbon-callout-body p {\n    font-size: 15px;\n    color: #94a3b8;\n    line-height: 1.6;\n    margin: 0;\n  }\n\n\n  .gas-grid {\n    display: flex;\n    flex-wrap: wrap;\n    gap: 10px;\n    margin-top: 20px;\n  }\n\n\n  .gas-tag {\n    display: inline-flex;\n    align-items: center;\n    gap: 7px;\n    padding: 8px 16px;\n    border-radius: 100px;\n    font-size: 14px;\n    font-weight: 700;\n    background: #1e293b;\n    color: #e2e8f0;\n    border: 1px solid #334155;\n    letter-spacing: .04em;\n  }\n\n\n  .gas-tag-dot {\n    width: 8px;\n    height: 8px;\n    border-radius: 50%;\n    background: #97e6e6;\n    flex-shrink: 0;\n  }\n\n\n  .application-list {\n    margin: 15px 0 0;\n    padding-left: 22px;\n  }\n\n\n  .application-list li {\n    margin-bottom: 8px;\n  }\n\n\n  .howto-steps {\n    list-style: none;\n    display: flex;\n    flex-direction: column;\n    margin: 0;\n    padding: 0;\n  }\n\n\n  .howto-step {\n    display: flex;\n    gap: 18px;\n    align-items: flex-start;\n    padding: 20px 0;\n    border-bottom: 1px solid #edf2f7;\n  }\n\n\n  .howto-step:last-child {\n    border-bottom: none;\n  }\n\n\n  .step-number {\n    flex-shrink: 0;\n    width: 54px;\n    height: 54px;\n    background: #007b8c;\n    color: #ffffff;\n    border-radius: 50%;\n    display: flex;\n    align-items: center;\n    justify-content: center;\n    font-weight: 700;\n    font-size: 18px;\n  }\n\n\n  .step-content {\n    flex: 1;\n  }\n\n\n  .step-content h3 {\n    margin-bottom: 6px;\n  }\n\n\n  .step-content p {\n    color: #4a5568;\n    margin: 0;\n  }\n\n\n  .specifications-table-wrapper {\n    overflow-x: auto;\n  }\n\n\n  .specifications-table {\n    width: 100%;\n    border-collapse: collapse;\n  }\n\n\n  .specifications-table th,\n  .specifications-table td {\n    padding: 14px 16px;\n    border-bottom: 1px solid #edf2f7;\n    text-align: left;\n    vertical-align: top;\n  }\n\n\n  .specifications-table th {\n    width: 35%;\n    background: #f8fafc;\n    color: #4a5568;\n    font-weight: 700;\n  }\n\n\n  .grade-grid {\n    display: grid;\n    grid-template-columns: repeat(4, minmax(0, 1fr));\n    gap: 0;\n    border-radius: 10px;\n    overflow: hidden;\n    border: 1px solid rgba(30,126,79,0.2);\n    margin-top: 10px;\n  }\n\n\n  .grade-tier {\n    padding: 22px 12px;\n    text-align: center;\n    border-right: 1px solid rgba(30,126,79,0.15);\n  }\n\n\n  .grade-tier:last-child {\n    border-right: none;\n  }\n\n\n  .grade-tier-m6 {\n    background: #eafaf1;\n  }\n\n\n  .grade-tier-f7 {\n    background: #d5f5e3;\n  }\n\n\n  .grade-tier-f8 {\n    background: #a9dfbf;\n  }\n\n\n  .grade-tier-f9 {\n    background: #7dcea0;\n  }\n\n\n  .grade-en {\n    display: block;\n    font-size: 13px;\n    font-weight: 700;\n    text-transform: uppercase;\n    letter-spacing: .1em;\n    color: #1a4731;\n    margin-bottom: 4px;\n  }\n\n\n  .grade-merv {\n    display: block;\n    font-size: 30px;\n    font-weight: 700;\n    color: #1a4731;\n    line-height: 1.1;\n    margin-bottom: 6px;\n  }\n\n\n  .grade-label {\n    display: block;\n    font-size: 13px;\n    color: #1a4731;\n    opacity: .75;\n  }\n\n\n  .procurement-section {\n    background: #f8fafc;\n  }\n\n\n  .faq-item {\n    border-bottom: 1px solid #edf2f7;\n    padding: 18px 0;\n  }\n\n\n  .faq-item:last-child {\n    border-bottom: 0;\n  }\n\n\n  .faq-item summary {\n    cursor: pointer;\n    color: #0f4c5c;\n    font-size: 18px;\n    font-weight: 700;\n    padding-right: 20px;\n  }\n\n\n  .faq-answer {\n    padding: 12px 0 0;\n    color: #4a5568;\n  }\n\n\n  .faq-answer p {\n    margin: 0;\n  }\n\n\n  .product-final {\n    background: #0f4c5c;\n    color: #ffffff;\n    padding: 35px;\n    border-radius: 14px;\n    margin-top: 35px;\n  }\n\n\n  .product-final h2 {\n    color: #ffffff;\n  }\n\n\n  .product-final p {\n    margin: 0;\n  }\n\n\n  @media (max-width: 1000px) {\n\n    .merv-selection-grid {\n      grid-template-columns: repeat(2, minmax(0, 1fr));\n    }\n\n    .grade-grid {\n      grid-template-columns: repeat(2, minmax(0, 1fr));\n    }\n\n    .grade-tier:nth-child(2) {\n      border-right: none;\n    }\n\n    .grade-tier:nth-child(-n+2) {\n      border-bottom: 1px solid rgba(30,126,79,0.15);\n    }\n\n  }\n\n\n  @media (max-width: 768px) {\n\n    .accurafil-product-description {\n      font-size: 15px;\n    }\n\n    .accurafil-product-description h2 {\n      font-size: 25px;\n    }\n\n    .benefits-grid,\n    .merv-selection-grid {\n      grid-template-columns: 1fr;\n    }\n\n    .product-intro,\n    .product-section,\n    .product-final {\n      padding: 22px;\n    }\n\n    .specifications-table th,\n    .specifications-table td {\n      padding: 11px;\n    }\n\n    .carbon-callout {\n      flex-direction: column;\n    }\n\n    .grade-grid {\n      grid-template-columns: 1fr;\n    }\n\n    .grade-tier {\n      border-right: none;\n      border-bottom: 1px solid rgba(30,126,79,0.15);\n    }\n\n    .grade-tier:last-child {\n      border-bottom: none;\n    }\n\n  }\n\n\u003c\/style\u003e","brand":"AccuraFil","offers":[{"title":"24 x 24 x 12 \/ MERV 11 \/ 4V","offer_id":48955351335220,"sku":"11-18-1210131-84-0","price":117.33,"currency_code":"USD","in_stock":true},{"title":"24 x 24 x 12 \/ MERV 14 \/ 2V","offer_id":48955351367988,"sku":"11-18-1410050-84-0","price":114.29,"currency_code":"USD","in_stock":true},{"title":"24 x 24 x 12 \/ MERV 14 \/ 4V","offer_id":48955351400756,"sku":"11-18-1410031-1252-0","price":118.37,"currency_code":"USD","in_stock":true},{"title":"24 x 24 x 12 \/ MERV 15 \/ 4V","offer_id":48955351433524,"sku":"11-18-1510031-84-0","price":123.31,"currency_code":"USD","in_stock":false},{"title":"24 x 20 x 12 \/ MERV 11 \/ 4V","offer_id":48955351466292,"sku":"11-18-1212131-310-0","price":108.02,"currency_code":"USD","in_stock":true},{"title":"24 x 20 x 12 \/ MERV 14 \/ 4V","offer_id":48955351499060,"sku":"11-18-1410000-310-0","price":108.3,"currency_code":"USD","in_stock":true},{"title":"24 x 20 x 12 \/ MERV 15 \/ 4V","offer_id":48955351531828,"sku":"11-18-1510131-310-0","price":108.3,"currency_code":"USD","in_stock":true},{"title":"20 x 20 x 12 \/ MERV 14 \/ 3V","offer_id":48955351564596,"sku":"11-18-1410061-1289-0","price":107.35,"currency_code":"USD","in_stock":true},{"title":"20 x 20 x 12 \/ MERV 15 \/ 3V","offer_id":48955351597364,"sku":"11-18-1512161-1289-0","price":111.82,"currency_code":"USD","in_stock":true},{"title":"20 x 16 x 12 \/ MERV 14 \/ 3V","offer_id":48955351630132,"sku":"11-18-1410161-172111-0","price":116.28,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0716\/7767\/3780\/files\/6.2V-BankFiberglassAirFilter-1.jpg?v=1757294942"},{"product_id":"v-bank-synthetic-air-filter","title":"V-Bank Synthetic Air Filter – MERV 15 – 4V","description":"\u003cdiv class=\"accurafil-product-description\"\u003e\n\n  \u003c!-- =========================================================\n       PRODUCT INTRODUCTION\n       ========================================================= --\u003e\n\n  \u003csection class=\"product-intro\" aria-labelledby=\"product-description-heading\"\u003e\n\n    \u003cp class=\"product-eyebrow\"\u003e\n      High-Efficiency Synthetic HVAC Filtration\n    \u003c\/p\u003e\n\n    \u003ch2 id=\"product-description-heading\"\u003e\n      V-Bank Synthetic Air Filter\n    \u003c\/h2\u003e\n\n    \u003cp\u003e\n      AccuraFil V-Bank Synthetic Air Filters combine\n      \u003cstrong\u003ehigh-efficiency synthetic media, mini-pleat construction,\n      and V-bank geometry\u003c\/strong\u003e in a rigid box-style HVAC filter designed\n      for high airflow and low resistance. The extended-surface design\n      provides a large effective filtration area within a compact filter\n      footprint.\n    \u003c\/p\u003e\n\n    \u003cp\u003e\n      Available in \u003cstrong\u003eMERV 11, MERV 13, MERV 14, and MERV 15\u003c\/strong\u003e\n      configurations according to ASHRAE 52.2, corresponding to\n      \u003cstrong\u003eM6, F7, F8, and F9\u003c\/strong\u003e classifications under EN 779.\n      The filter uses high-efficiency synthetic media with thermoplastic\n      bead separators and an ABS plastic frame with a 20 mm header.\n      Its rigid construction is designed for variable and turbulent\n      airflow applications, including VAV systems, air handlers, built-up\n      filter banks, healthcare facilities, pharmaceutical environments,\n      data centers, and commercial HVAC systems.\n    \u003c\/p\u003e\n\n  \u003c\/section\u003e\n\n\n  \u003c!-- =========================================================\n       KEY BENEFITS\n       ========================================================= --\u003e\n\n  \u003csection class=\"product-section\" aria-labelledby=\"key-benefits-heading\"\u003e\n\n    \u003ch2 id=\"key-benefits-heading\"\u003e\n      Key Benefits\n    \u003c\/h2\u003e\n\n    \u003cdiv class=\"benefits-grid\"\u003e\n\n      \u003carticle class=\"benefit-card\"\u003e\n\n        \u003ch3\u003e\n          High-Efficiency Synthetic Media\n        \u003c\/h3\u003e\n\n        \u003cp\u003e\n          Synthetic filtration media provides efficient particulate\n          filtration across MERV 11 through MERV 15 configurations while\n          supporting resistance to moisture and demanding airflow conditions.\n        \u003c\/p\u003e\n\n      \u003c\/article\u003e\n\n\n      \u003carticle class=\"benefit-card\"\u003e\n\n        \u003ch3\u003e\n          Mini-Pleat V-Bank Design\n        \u003c\/h3\u003e\n\n        \u003cp\u003e\n          Extended-surface mini-pleat geometry maximizes effective media\n          area within the available filter footprint to support high airflow\n          with reduced resistance.\n        \u003c\/p\u003e\n\n      \u003c\/article\u003e\n\n\n      \u003carticle class=\"benefit-card\"\u003e\n\n        \u003ch3\u003e\n          Turbulence-Resistant Construction\n        \u003c\/h3\u003e\n\n        \u003cp\u003e\n          Rigid box construction and thermoplastic bead separators help\n          maintain pleat geometry and filtration performance under variable\n          and turbulent airflow conditions.\n        \u003c\/p\u003e\n\n      \u003c\/article\u003e\n\n\n      \u003carticle class=\"benefit-card\"\u003e\n\n        \u003ch3\u003e\n          Fully Incinerable Construction\n        \u003c\/h3\u003e\n\n        \u003cp\u003e\n          The non-metallic filter construction is fully incinerable,\n          allowing end-of-life disposal without separating metallic frame\n          components from the filter media.\n        \u003c\/p\u003e\n\n      \u003c\/article\u003e\n\n    \u003c\/div\u003e\n\n  \u003c\/section\u003e\n\n\n  \u003c!-- =========================================================\n       TECHNICAL SPECIFICATIONS\n       ========================================================= --\u003e\n\n  \u003csection class=\"product-section\" aria-labelledby=\"specifications-heading\"\u003e\n\n    \u003ch2 id=\"specifications-heading\"\u003e\n      Technical Specifications\n    \u003c\/h2\u003e\n\n    \u003cdiv class=\"specifications-table-wrapper\"\u003e\n\n      \u003ctable class=\"specifications-table\"\u003e\n\n        \u003ctbody\u003e\n\n          \u003ctr\u003e\n            \u003cth scope=\"row\"\u003e\n              Filter Type\n            \u003c\/th\u003e\n\n            \u003ctd\u003e\n              V-Bank Synthetic Air Filter — Rigid Box\n            \u003c\/td\u003e\n          \u003c\/tr\u003e\n\n\n          \u003ctr\u003e\n            \u003cth scope=\"row\"\u003e\n              Filter Grades\n            \u003c\/th\u003e\n\n            \u003ctd\u003e\n              MERV 15\n            \u003c\/td\u003e\n          \u003c\/tr\u003e\n\n\n          \u003ctr\u003e\n            \u003cth scope=\"row\"\u003e\n              Filtration Standard\n            \u003c\/th\u003e\n\n            \u003ctd\u003e\n              ASHRAE 52.2\n            \u003c\/td\u003e\n          \u003c\/tr\u003e\n\n\n          \u003ctr\u003e\n            \u003cth scope=\"row\"\u003e\n              EN 779 Grades\n            \u003c\/th\u003e\n\n            \u003ctd\u003e\n              F9\n            \u003c\/td\u003e\n          \u003c\/tr\u003e\n\n\n          \u003ctr\u003e\n            \u003cth scope=\"row\"\u003e\n              Filter Media\n            \u003c\/th\u003e\n\n            \u003ctd\u003e\n              High-Efficiency Synthetic Media\n            \u003c\/td\u003e\n          \u003c\/tr\u003e\n\n\n          \u003ctr\u003e\n            \u003cth scope=\"row\"\u003e\n              Media Separator\n            \u003c\/th\u003e\n\n            \u003ctd\u003e\n              Thermoplastic Bead Separators (Hot Melt Beads)\n            \u003c\/td\u003e\n          \u003c\/tr\u003e\n\n\n          \u003ctr\u003e\n            \u003cth scope=\"row\"\u003e\n              Frame Material\n            \u003c\/th\u003e\n\n            \u003ctd\u003e\n              ABS Plastic\n            \u003c\/td\u003e\n          \u003c\/tr\u003e\n\n\n          \u003ctr\u003e\n            \u003cth scope=\"row\"\u003e\n              Header Construction\n            \u003c\/th\u003e\n\n            \u003ctd\u003e\n              20 mm Header\n            \u003c\/td\u003e\n          \u003c\/tr\u003e\n\n\n          \u003ctr\u003e\n            \u003cth scope=\"row\"\u003e\n              Maximum Operating Temperature\n            \u003c\/th\u003e\n\n            \u003ctd\u003e\n              176°F (80°C)\n            \u003c\/td\u003e\n          \u003c\/tr\u003e\n\n\n          \u003ctr\u003e\n            \u003cth scope=\"row\"\u003e\n              Final Pressure Drop\n            \u003c\/th\u003e\n\n            \u003ctd\u003e\n              1.50\" w.g.\n            \u003c\/td\u003e\n          \u003c\/tr\u003e\n\n\n          \u003ctr\u003e\n            \u003cth scope=\"row\"\u003e\n              Maximum Recommended Pressure Drop\n            \u003c\/th\u003e\n\n            \u003ctd\u003e\n              2.00\" w.g.\n            \u003c\/td\u003e\n          \u003c\/tr\u003e\n\n\n          \u003ctr\u003e\n            \u003cth scope=\"row\"\u003e\n              Maximum Operating Velocity\n            \u003c\/th\u003e\n\n            \u003ctd\u003e\n              625 fpm \/ 3.175 m\/s\n            \u003c\/td\u003e\n          \u003c\/tr\u003e\n\n\n          \u003ctr\u003e\n            \u003cth scope=\"row\"\u003e\n              Disposal\n            \u003c\/th\u003e\n\n            \u003ctd\u003e\n              Fully Incinerable, Non-Metallic Construction\n            \u003c\/td\u003e\n          \u003c\/tr\u003e\n\u003ctr\u003e\n            \u003cth scope=\"row\"\u003e\n              Fire Classification\n            \u003c\/th\u003e\n\n            \u003ctd\u003e\n              UL900 Classified\n            \u003c\/td\u003e\n        \u003c\/tr\u003e\n\u003c\/tbody\u003e\n\n      \u003c\/table\u003e\n\n    \u003c\/div\u003e\n\n  \u003c\/section\u003e\n\n\n  \u003c!-- =========================================================\n       SYNTHETIC MEDIA PERFORMANCE\n       ========================================================= --\u003e\n\n  \u003csection class=\"product-section\" aria-labelledby=\"synthetic-performance-heading\"\u003e\n\n    \u003ch2 id=\"synthetic-performance-heading\"\u003e\n      High-Efficiency Synthetic Media Performance\n    \u003c\/h2\u003e\n\n    \u003cp\u003e\n      The V-Bank Synthetic Filter uses\n      \u003cstrong\u003ehigh-efficiency synthetic filtration media\u003c\/strong\u003e arranged\n      in a mini-pleat configuration. The extended media surface area allows\n      the filter to provide efficient particulate filtration while\n      maintaining the compact rigid-box format required by many HVAC\n      installations.\n    \u003c\/p\u003e\n\n    \u003cp\u003e\n      The synthetic media construction is designed for demanding operating\n      conditions where moisture exposure, variable airflow, and turbulence\n      can affect conventional filter designs. The filter is available from\n      MERV 11 through MERV 15 to accommodate different particulate\n      filtration requirements.\n    \u003c\/p\u003e\n\n    \u003cdiv class=\"synthetic-callout\"\u003e\n\n      \u003cdiv class=\"synthetic-callout-icon\" aria-hidden=\"true\"\u003e\n        🧵\n      \u003c\/div\u003e\n\n      \u003cdiv class=\"synthetic-callout-body\"\u003e\n\n        \u003cstrong\u003e\n          Durable Synthetic Filtration\n        \u003c\/strong\u003e\n\n        \u003cp\u003e\n          High-efficiency synthetic media provides a combination of\n          particulate filtration, moisture resistance, and durability for\n          demanding HVAC applications.\n        \u003c\/p\u003e\n\n      \u003c\/div\u003e\n\n    \u003c\/div\u003e\n\n  \u003c\/section\u003e\n\n\n  \u003c!-- =========================================================\n       FILTER GRADE SELECTION\n       ========================================================= --\u003e\n\n  \u003csection class=\"product-section\" aria-labelledby=\"grade-selection-heading\"\u003e\n\n    \u003ch2 id=\"grade-selection-heading\"\u003e\n      MERV \u0026amp; EN 779 Filter Grade Selection\n    \u003c\/h2\u003e\n\n    \u003cp\u003e\n      Select the appropriate filter grade according to the facility's\n      particulate filtration requirements, HVAC design, airflow conditions,\n      and allowable pressure drop.\n    \u003c\/p\u003e\n\n    \u003cdiv class=\"grade-selection-grid\"\u003e\n\n      \u003carticle class=\"grade-selection-card\"\u003e\n\n        \u003cspan class=\"grade-standard\"\u003e\n          EN 779 M6\n        \u003c\/span\u003e\n\n        \u003ch3\u003e\n          MERV 11\n        \u003c\/h3\u003e\n\n        \u003cp\u003e\n          Suitable for general commercial ventilation and applications\n          requiring moderate particulate filtration performance.\n        \u003c\/p\u003e\n\n      \u003c\/article\u003e\n\n\n      \u003carticle class=\"grade-selection-card\"\u003e\n\n        \u003cspan class=\"grade-standard\"\u003e\n          EN 779 F7\n        \u003c\/span\u003e\n\n        \u003ch3\u003e\n          MERV 13\n        \u003c\/h3\u003e\n\n        \u003cp\u003e\n          Higher-efficiency particulate filtration for offices, hotels,\n          light healthcare, and commercial HVAC applications.\n        \u003c\/p\u003e\n\n      \u003c\/article\u003e\n\n\n      \u003carticle class=\"grade-selection-card\"\u003e\n\n        \u003cspan class=\"grade-standard\"\u003e\n          EN 779 F8\n        \u003c\/span\u003e\n\n        \u003ch3\u003e\n          MERV 14\n        \u003c\/h3\u003e\n\n        \u003cp\u003e\n          Higher filtration efficiency for hospitals, laboratories,\n          LEED buildings, and other demanding commercial applications.\n        \u003c\/p\u003e\n\n      \u003c\/article\u003e\n\n\n      \u003carticle class=\"grade-selection-card\"\u003e\n\n        \u003cspan class=\"grade-standard\"\u003e\n          EN 779 F9\n        \u003c\/span\u003e\n\n        \u003ch3\u003e\n          MERV 15\n        \u003c\/h3\u003e\n\n        \u003cp\u003e\n          High-efficiency particulate filtration for pharmaceutical,\n          ISO cleanroom, healthcare, and critical HVAC environments.\n        \u003c\/p\u003e\n\n      \u003c\/article\u003e\n\n    \u003c\/div\u003e\n\n  \u003c\/section\u003e\n\n\n  \u003c!-- =========================================================\n       V-BANK DESIGN\n       ========================================================= --\u003e\n\n  \u003csection class=\"product-section\" aria-labelledby=\"vbank-design-heading\"\u003e\n\n    \u003ch2 id=\"vbank-design-heading\"\u003e\n      V-Bank Mini-Pleat Design for High Airflow\n    \u003c\/h2\u003e\n\n    \u003cp\u003e\n      The V-bank configuration divides the filter media into angled\n      sections, increasing the effective filtration surface area available\n      within the filter footprint. Combined with the mini-pleat design,\n      this configuration supports high airflow while minimizing resistance.\n    \u003c\/p\u003e\n\n    \u003cp\u003e\n      The extended-surface construction is designed to provide greater\n      media utilization than conventional flat panel arrangements while\n      maintaining a compact rigid box configuration suitable for air\n      handlers, filter banks, and VAV systems.\n    \u003c\/p\u003e\n\n  \u003c\/section\u003e\n\n\n  \u003c!-- =========================================================\n       AIRFLOW \u0026 TURBULENCE PERFORMANCE\n       ========================================================= --\u003e\n\n  \u003csection class=\"product-section\" aria-labelledby=\"airflow-performance-heading\"\u003e\n\n    \u003ch2 id=\"airflow-performance-heading\"\u003e\n      Performance Under Variable \u0026amp; Turbulent Airflow\n    \u003c\/h2\u003e\n\n    \u003cp\u003e\n      The rigid box construction and thermoplastic bead separators are\n      designed to maintain consistent pleat geometry under variable\n      airflow and turbulent operating conditions. This makes the V-Bank\n      Synthetic Filter particularly suitable for HVAC systems where\n      airflow demand changes during operation.\n    \u003c\/p\u003e\n\n    \u003cdiv class=\"performance-grid\"\u003e\n\n      \u003carticle class=\"performance-card\"\u003e\n\n        \u003ch3\u003e\n          Maximum Operating Velocity\n        \u003c\/h3\u003e\n\n        \u003cp\u003e\n          The specified maximum operating velocity is\n          \u003cstrong\u003e625 fpm (3.175 m\/s)\u003c\/strong\u003e.\n        \u003c\/p\u003e\n\n      \u003c\/article\u003e\n\n\n      \u003carticle class=\"performance-card\"\u003e\n\n        \u003ch3\u003e\n          Final Pressure Drop\n        \u003c\/h3\u003e\n\n        \u003cp\u003e\n          The specified final pressure drop is\n          \u003cstrong\u003e1.50\" w.g.\u003c\/strong\u003e.\n        \u003c\/p\u003e\n\n      \u003c\/article\u003e\n\n\n      \u003carticle class=\"performance-card\"\u003e\n\n        \u003ch3\u003e\n          Maximum Recommended Pressure Drop\n        \u003c\/h3\u003e\n\n        \u003cp\u003e\n          The maximum recommended pressure drop is\n          \u003cstrong\u003e2.00\" w.g.\u003c\/strong\u003e.\n        \u003c\/p\u003e\n\n      \u003c\/article\u003e\n\n\n      \u003carticle class=\"performance-card\"\u003e\n\n        \u003ch3\u003e\n          Turbulence-Resistant Design\n        \u003c\/h3\u003e\n\n        \u003cp\u003e\n          Rigid construction and thermoplastic bead separators help maintain\n          pleat spacing during variable airflow conditions.\n        \u003c\/p\u003e\n\n      \u003c\/article\u003e\n\n    \u003c\/div\u003e\n\n  \u003c\/section\u003e\n\n\n  \u003c!-- =========================================================\n       FRAME \u0026 HEADER\n       ========================================================= --\u003e\n\n  \u003csection class=\"product-section\" aria-labelledby=\"frame-heading\"\u003e\n\n    \u003ch2 id=\"frame-heading\"\u003e\n      ABS Frame \u0026amp; 20 mm Header Construction\n    \u003c\/h2\u003e\n\n    \u003cp\u003e\n      The V-Bank Synthetic Filter uses a\n      \u003cstrong\u003enon-metallic ABS plastic frame\u003c\/strong\u003e designed to provide\n      a lightweight and durable enclosure for the synthetic media pack.\n    \u003c\/p\u003e\n\n    \u003cp\u003e\n      The \u003cstrong\u003e20 mm header\u003c\/strong\u003e provides the mounting interface\n      for compatible HVAC filter racks and built-up filter bank systems.\n    \u003c\/p\u003e\n\n    \u003cp\u003e\n      Always verify the existing housing dimensions, header configuration,\n      sealing arrangement, and installation orientation before ordering\n      a replacement filter.\n    \u003c\/p\u003e\n\n  \u003c\/section\u003e\n\n\n  \u003c!-- =========================================================\n       DISPOSAL\n       ========================================================= --\u003e\n\n  \u003csection class=\"product-section\" aria-labelledby=\"disposal-heading\"\u003e\n\n    \u003ch2 id=\"disposal-heading\"\u003e\n      Fully Incinerable Non-Metallic Construction\n    \u003c\/h2\u003e\n\n    \u003cp\u003e\n      The V-Bank Synthetic Filter uses a\n      \u003cstrong\u003enon-metallic, fully incinerable construction\u003c\/strong\u003e.\n      The filter can be disposed of by incineration without separating\n      metallic frame components from the filter media.\n    \u003c\/p\u003e\n\n    \u003cp\u003e\n      This construction can simplify end-of-life handling for facilities\n      where incinerable filter disposal is preferred or required,\n      including compatible pharmaceutical, healthcare, food processing,\n      and other controlled environments.\n    \u003c\/p\u003e\n\n  \u003c\/section\u003e\n\n\n  \u003c!-- =========================================================\n       INDUSTRY APPLICATIONS\n       ========================================================= --\u003e\n\n  \u003csection class=\"product-section\" aria-labelledby=\"applications-heading\"\u003e\n\n    \u003ch2 id=\"applications-heading\"\u003e\n      Commercial \u0026amp; Industrial HVAC Applications\n    \u003c\/h2\u003e\n\n    \u003cp\u003e\n      AccuraFil V-Bank Synthetic Filters are designed for high-efficiency\n      particulate filtration in a wide range of commercial and industrial\n      HVAC applications, including:\n    \u003c\/p\u003e\n\n    \u003cul class=\"application-list\"\u003e\n\n      \u003cli\u003e\n        Variable Air Volume (VAV) systems\n      \u003c\/li\u003e\n\n      \u003cli\u003e\n        Commercial office buildings and hotels\n      \u003c\/li\u003e\n\n      \u003cli\u003e\n        Hospitals and healthcare facilities\n      \u003c\/li\u003e\n\n      \u003cli\u003e\n        Pharmaceutical and biotechnology facilities\n      \u003c\/li\u003e\n\n      \u003cli\u003e\n        Laboratories and controlled environments\n      \u003c\/li\u003e\n\n      \u003cli\u003e\n        Data centers and mission-critical facilities\n      \u003c\/li\u003e\n\n      \u003cli\u003e\n        Built-up HVAC filter banks\n      \u003c\/li\u003e\n\n      \u003cli\u003e\n        Air handling units and commercial HVAC systems\n      \u003c\/li\u003e\n\n      \u003cli\u003e\n        High-humidity HVAC environments\n      \u003c\/li\u003e\n\n      \u003cli\u003e\n        Food processing facilities requiring compatible incinerable\n        filter construction\n      \u003c\/li\u003e\n\n    \u003c\/ul\u003e\n\n  \u003c\/section\u003e\n\n\n  \u003c!-- =========================================================\n       HIGH-DEMAND ENVIRONMENTS\n       ========================================================= --\u003e\n\n  \u003csection class=\"product-section\" aria-labelledby=\"high-demand-heading\"\u003e\n\n    \u003ch2 id=\"high-demand-heading\"\u003e\n      Reliable Performance in High-Demand Environments\n    \u003c\/h2\u003e\n\n    \u003cp\u003e\n      The combination of high-efficiency synthetic media, mini-pleat\n      V-bank geometry, and rigid box construction makes the filter suitable\n      for HVAC systems exposed to high airflow, variable operating\n      conditions, and demanding maintenance requirements.\n    \u003c\/p\u003e\n\n\n    \u003ch3\u003e\n      VAV \u0026amp; Turbulent Airflow Systems\n    \u003c\/h3\u003e\n\n    \u003cp\u003e\n      The rigid filter construction and thermoplastic bead separators are\n      designed to help maintain media geometry and filtration performance\n      under variable airflow conditions.\n    \u003c\/p\u003e\n\n\n    \u003ch3\u003e\n      Hospitals \u0026amp; Healthcare\n    \u003c\/h3\u003e\n\n    \u003cp\u003e\n      High-efficiency MERV configurations provide particulate filtration\n      for compatible healthcare HVAC systems, while the non-metallic\n      construction supports simplified incinerable disposal.\n    \u003c\/p\u003e\n\n\n    \u003ch3\u003e\n      Pharmaceutical Manufacturing\n    \u003c\/h3\u003e\n\n    \u003cp\u003e\n      MERV 14 and MERV 15 configurations provide high-efficiency\n      particulate filtration for compatible pharmaceutical and controlled\n      environments where airflow stability and end-of-life handling are\n      important considerations.\n    \u003c\/p\u003e\n\n\n    \u003ch3\u003e\n      Data Centers\n    \u003c\/h3\u003e\n\n    \u003cp\u003e\n      High-efficiency synthetic filtration helps provide particulate control\n      for sensitive electronic environments, while the rigid V-bank design\n      supports demanding continuous HVAC operation.\n    \u003c\/p\u003e\n\n\n    \u003ch3\u003e\n      High-Humidity Environments\n    \u003c\/h3\u003e\n\n    \u003cp\u003e\n      Synthetic media is designed to resist moisture-related degradation,\n      supporting applications where elevated humidity is an important\n      operating consideration.\n    \u003c\/p\u003e\n\n\n    \u003ch3\u003e\n      Built-Up Filter Banks\n    \u003c\/h3\u003e\n\n    \u003cp\u003e\n      The rigid box configuration with ABS frame and 20 mm header is\n      designed for installation in compatible cell housings and\n      multi-filter HVAC bank configurations.\n    \u003c\/p\u003e\n\n  \u003c\/section\u003e\n\n\n  \u003c!-- =========================================================\n       PERFORMANCE BENEFITS\n       ========================================================= --\u003e\n\n  \u003csection class=\"product-section\" aria-labelledby=\"performance-heading\"\u003e\n\n    \u003ch2 id=\"performance-heading\"\u003e\n      High-Airflow Synthetic Filtration Performance\n    \u003c\/h2\u003e\n\n    \u003cdiv class=\"benefits-grid\"\u003e\n\n      \u003carticle class=\"benefit-card\"\u003e\n\n        \u003ch3\u003e\n          Large Effective Media Area\n        \u003c\/h3\u003e\n\n        \u003cp\u003e\n          Mini-pleat V-bank geometry increases the effective filtration\n          surface area within the available filter footprint.\n        \u003c\/p\u003e\n\n      \u003c\/article\u003e\n\n\n      \u003carticle class=\"benefit-card\"\u003e\n\n        \u003ch3\u003e\n          Lower Resistance\n        \u003c\/h3\u003e\n\n        \u003cp\u003e\n          The extended-surface design is engineered to support efficient\n          airflow with controlled pressure resistance.\n        \u003c\/p\u003e\n\n      \u003c\/article\u003e\n\n\n      \u003carticle class=\"benefit-card\"\u003e\n\n        \u003ch3\u003e\n          Durable Synthetic Media\n        \u003c\/h3\u003e\n\n        \u003cp\u003e\n          Synthetic media provides a resilient filtration structure for\n          variable airflow and elevated-humidity HVAC conditions.\n        \u003c\/p\u003e\n\n      \u003c\/article\u003e\n\n\n      \u003carticle class=\"benefit-card\"\u003e\n\n        \u003ch3\u003e\n          Reduced Filter Handling Complexity\n        \u003c\/h3\u003e\n\n        \u003cp\u003e\n          Fully incinerable non-metallic construction can simplify\n          end-of-life handling where incineration is an applicable\n          disposal method.\n        \u003c\/p\u003e\n\n      \u003c\/article\u003e\n\n    \u003c\/div\u003e\n\n  \u003c\/section\u003e\n\n\n  \u003c!-- =========================================================\n       SELECTION GUIDE\n       ========================================================= --\u003e\n\n  \u003csection class=\"product-section\" aria-labelledby=\"selection-guide-heading\"\u003e\n\n    \u003ch2 id=\"selection-guide-heading\"\u003e\n      How to Select the Right V-Bank Synthetic Filter\n    \u003c\/h2\u003e\n\n    \u003col class=\"howto-steps\"\u003e\n\n      \u003cli class=\"howto-step\"\u003e\n\n        \u003cspan class=\"step-number\" aria-hidden=\"true\"\u003e\n          1\n        \u003c\/span\u003e\n\n        \u003cdiv class=\"step-content\"\u003e\n\n          \u003ch3\u003e\n            Identify the Required MERV Rating\n          \u003c\/h3\u003e\n\n          \u003cp\u003e\n            Select MERV 11, MERV 13, MERV 14, or MERV 15 according to the\n            particulate filtration requirements of the facility and HVAC\n            application.\n          \u003c\/p\u003e\n\n        \u003c\/div\u003e\n\n      \u003c\/li\u003e\n\n\n      \u003cli class=\"howto-step\"\u003e\n\n        \u003cspan class=\"step-number\" aria-hidden=\"true\"\u003e\n          2\n        \u003c\/span\u003e\n\n        \u003cdiv class=\"step-content\"\u003e\n\n          \u003ch3\u003e\n            Verify Airflow \u0026amp; Pressure-Drop Requirements\n          \u003c\/h3\u003e\n\n          \u003cp\u003e\n            Confirm that system airflow remains within the specified\n            maximum operating velocity of \u003cstrong\u003e625 fpm\n            (3.175 m\/s)\u003c\/strong\u003e and that the HVAC system can accommodate\n            the specified pressure-drop conditions.\n          \u003c\/p\u003e\n\n        \u003c\/div\u003e\n\n      \u003c\/li\u003e\n\n\n      \u003cli class=\"howto-step\"\u003e\n\n        \u003cspan class=\"step-number\" aria-hidden=\"true\"\u003e\n          3\n        \u003c\/span\u003e\n\n        \u003cdiv class=\"step-content\"\u003e\n\n          \u003ch3\u003e\n            Confirm Housing Compatibility\n          \u003c\/h3\u003e\n\n          \u003cp\u003e\n            Verify that the existing housing accepts the required\n            \u003cstrong\u003eV-bank rigid box configuration with ABS frame and\n            20 mm header\u003c\/strong\u003e. Confirm actual filter dimensions,\n            mounting arrangement, and sealing requirements before ordering.\n          \u003c\/p\u003e\n\n        \u003c\/div\u003e\n\n      \u003c\/li\u003e\n\n\n      \u003cli class=\"howto-step\"\u003e\n\n        \u003cspan class=\"step-number\" aria-hidden=\"true\"\u003e\n          4\n        \u003c\/span\u003e\n\n        \u003cdiv class=\"step-content\"\u003e\n\n          \u003ch3\u003e\n            Verify Operating Conditions \u0026amp; Disposal Requirements\n          \u003c\/h3\u003e\n\n          \u003cp\u003e\n            Confirm operating temperature does not exceed\n            \u003cstrong\u003e176°F (80°C)\u003c\/strong\u003e. Where incinerable disposal is\n            applicable, confirm that the facility's disposal process accepts\n            the filter's fully incinerable non-metallic construction.\n          \u003c\/p\u003e\n\n        \u003c\/div\u003e\n\n      \u003c\/li\u003e\n\n    \u003c\/ol\u003e\n\n  \u003c\/section\u003e\n\n\n  \u003c!-- =========================================================\n       PRODUCT COMPARISON\n       ========================================================= --\u003e\n\n  \u003csection class=\"product-section\" aria-labelledby=\"comparison-heading\"\u003e\n\n    \u003ch2 id=\"comparison-heading\"\u003e\n      V-Bank Synthetic Filter vs. Bag Filters \u0026amp; Standard Box Filters\n    \u003c\/h2\u003e\n\n    \u003cp\u003e\n      Compared with conventional bag-style filters, the V-Bank Synthetic\n      Filter uses a rigid box configuration and mini-pleat V-bank geometry.\n      This provides a more structurally stable format for applications\n      exposed to variable or turbulent airflow while maximizing the\n      available media surface area within the filter footprint.\n    \u003c\/p\u003e\n\n    \u003cp\u003e\n      Compared with conventional standard box filters, the mini-pleat\n      V-bank configuration is designed to provide high effective media\n      area and efficient airflow in a compact rigid construction. Synthetic\n      media additionally provides moisture resistance and a fully\n      incinerable non-metallic construction for compatible applications.\n    \u003c\/p\u003e\n\n    \u003cp\u003e\n      The appropriate filter selection depends on required MERV efficiency,\n      airflow, pressure drop, housing configuration, operating environment,\n      and disposal requirements.\n    \u003c\/p\u003e\n\n  \u003c\/section\u003e\n\n\n  \u003c!-- =========================================================\n       PRODUCT SELECTION \u0026 PROCUREMENT\n       ========================================================= --\u003e\n\n  \u003csection class=\"product-section procurement-section\" aria-labelledby=\"procurement-heading\"\u003e\n\n    \u003ch2 id=\"procurement-heading\"\u003e\n      Product Selection \u0026amp; Procurement\n    \u003c\/h2\u003e\n\n    \u003cp\u003e\n      Before ordering a replacement V-Bank Synthetic Filter, verify the\n      \u003cstrong\u003eactual filter dimensions\u003c\/strong\u003e, MERV rating, V-bank\n      configuration, ABS frame and 20 mm header requirements, airflow,\n      pressure-drop limitations, and compatibility with the existing HVAC\n      housing or filter bank.\n    \u003c\/p\u003e\n\n    \u003cp\u003e\n      For variable-airflow systems, confirm that the application operates\n      within the specified maximum velocity and pressure-drop limits.\n      Verify that the filter construction is suitable for the operating\n      temperature and humidity conditions.\n    \u003c\/p\u003e\n\n    \u003cp\u003e\n      Where incinerable disposal is required, confirm that the facility's\n      disposal process accepts fully incinerable non-metallic filter\n      construction without requiring separation of components.\n    \u003c\/p\u003e\n\n    \u003cp\u003e\n      AccuraFil provides commercial and industrial HVAC filtration solutions\n      for facility managers, HVAC contractors, mechanical engineers,\n      healthcare organizations, pharmaceutical facilities, data center\n      operators, filter-bank designers, and procurement teams.\n    \u003c\/p\u003e\n\n  \u003c\/section\u003e\n\n\n  \u003c!-- =========================================================\n       FAQ\n       ========================================================= --\u003e\n\n  \u003csection class=\"product-section\" aria-labelledby=\"faq-heading\"\u003e\n\n    \u003ch2 id=\"faq-heading\"\u003e\n      Frequently Asked Questions\n    \u003c\/h2\u003e\n\n\n    \u003cdetails class=\"faq-item\"\u003e\n\n      \u003csummary\u003e\n        What is a V-Bank Synthetic Filter?\n      \u003c\/summary\u003e\n\n      \u003cdiv class=\"faq-answer\"\u003e\n\n        \u003cp\u003e\n          A V-Bank Synthetic Filter is a rigid box-style HVAC filter that\n          uses high-efficiency synthetic media arranged in a V-bank\n          mini-pleat configuration. The design provides an extended\n          filtration surface within a compact footprint and is intended\n          for efficient airflow and demanding HVAC applications.\n        \u003c\/p\u003e\n\n      \u003c\/div\u003e\n\n    \u003c\/details\u003e\n\n\n    \u003cdetails class=\"faq-item\"\u003e\n\n      \u003csummary\u003e\n        What MERV ratings are available?\n      \u003c\/summary\u003e\n\n      \u003cdiv class=\"faq-answer\"\u003e\n\n        \u003cp\u003e\n          The AccuraFil V-Bank Synthetic Filter is available in\n          \u003cstrong\u003eMERV 11, MERV 13, MERV 14, and MERV 15\u003c\/strong\u003e according\n          to the supplied product specifications. These correspond to\n          EN 779 classifications M6, F7, F8, and F9 respectively.\n        \u003c\/p\u003e\n\n      \u003c\/div\u003e\n\n    \u003c\/details\u003e\n\n\n    \u003cdetails class=\"faq-item\"\u003e\n\n      \u003csummary\u003e\n        What are the advantages of synthetic media?\n      \u003c\/summary\u003e\n\n      \u003cdiv class=\"faq-answer\"\u003e\n\n        \u003cp\u003e\n          High-efficiency synthetic media provides a resilient filtration\n          structure and is designed to resist moisture-related degradation.\n          This makes it suitable for compatible HVAC applications involving\n          variable airflow, turbulence, or elevated humidity.\n        \u003c\/p\u003e\n\n      \u003c\/div\u003e\n\n    \u003c\/details\u003e\n\n\n    \u003cdetails class=\"faq-item\"\u003e\n\n      \u003csummary\u003e\n        What are thermoplastic bead separators?\n      \u003c\/summary\u003e\n\n      \u003cdiv class=\"faq-answer\"\u003e\n\n        \u003cp\u003e\n          Thermoplastic bead separators, also known as hot melt beads,\n          maintain the spacing between the mini-pleats in the synthetic\n          media pack. Their non-metallic construction contributes to the\n          filter's fully incinerable design.\n        \u003c\/p\u003e\n\n      \u003c\/div\u003e\n\n    \u003c\/details\u003e\n\n\n    \u003cdetails class=\"faq-item\"\u003e\n\n      \u003csummary\u003e\n        How does the V-Bank Synthetic Filter perform under turbulent airflow?\n      \u003c\/summary\u003e\n\n      \u003cdiv class=\"faq-answer\"\u003e\n\n        \u003cp\u003e\n          The rigid box construction and thermoplastic bead separators are\n          designed to help maintain pleat geometry and filtration performance\n          under variable and turbulent airflow conditions. This makes the\n          filter suitable for VAV systems and other applications where\n          airflow conditions fluctuate during operation.\n        \u003c\/p\u003e\n\n      \u003c\/div\u003e\n\n    \u003c\/details\u003e\n\n\n    \u003cdetails class=\"faq-item\"\u003e\n\n      \u003csummary\u003e\n        What is the maximum operating velocity?\n      \u003c\/summary\u003e\n\n      \u003cdiv class=\"faq-answer\"\u003e\n\n        \u003cp\u003e\n          The specified maximum operating velocity is\n          \u003cstrong\u003e625 fpm (3.175 m\/s)\u003c\/strong\u003e. HVAC system airflow should\n          be verified against this limit before specifying the filter.\n        \u003c\/p\u003e\n\n      \u003c\/div\u003e\n\n    \u003c\/details\u003e\n\n\n    \u003cdetails class=\"faq-item\"\u003e\n\n      \u003csummary\u003e\n        What frame and header configuration does the filter use?\n      \u003c\/summary\u003e\n\n      \u003cdiv class=\"faq-answer\"\u003e\n\n        \u003cp\u003e\n          The specified configuration uses a\n          \u003cstrong\u003enon-metallic ABS plastic frame with a 20 mm header\u003c\/strong\u003e.\n          Verify that the existing HVAC filter housing or built-up filter\n          bank is compatible with this configuration before ordering.\n        \u003c\/p\u003e\n\n      \u003c\/div\u003e\n\n    \u003c\/details\u003e\n\n\n    \u003cdetails class=\"faq-item\"\u003e\n\n      \u003csummary\u003e\n        Is the V-Bank Synthetic Filter fully incinerable?\n      \u003c\/summary\u003e\n\n      \u003cdiv class=\"faq-answer\"\u003e\n\n        \u003cp\u003e\n          Yes. The supplied product specifications identify the filter as\n          having a \u003cstrong\u003efully incinerable, non-metallic construction\u003c\/strong\u003e.\n          Confirm that the facility's disposal process accepts this disposal\n          method before use.\n        \u003c\/p\u003e\n\n      \u003c\/div\u003e\n\n    \u003c\/details\u003e\n\n\n    \u003cdetails class=\"faq-item\"\u003e\n\n      \u003csummary\u003e\n        What is the maximum operating temperature?\n      \u003c\/summary\u003e\n\n      \u003cdiv class=\"faq-answer\"\u003e\n\n        \u003cp\u003e\n          The specified maximum operating temperature is\n          \u003cstrong\u003e176°F (80°C)\u003c\/strong\u003e.\n        \u003c\/p\u003e\n\n      \u003c\/div\u003e\n\n    \u003c\/details\u003e\n\n\n    \u003cdetails class=\"faq-item\"\u003e\n\n      \u003csummary\u003e\n        What is the recommended final pressure drop?\n      \u003c\/summary\u003e\n\n      \u003cdiv class=\"faq-answer\"\u003e\n\n        \u003cp\u003e\n          The specified final pressure drop is\n          \u003cstrong\u003e1.50\" w.g.\u003c\/strong\u003e, with a maximum recommended pressure\n          drop of \u003cstrong\u003e2.00\" w.g.\u003c\/strong\u003e. Confirm that the HVAC system\n          can support the required pressure-drop conditions before ordering.\n        \u003c\/p\u003e\n\n      \u003c\/div\u003e\n\n    \u003c\/details\u003e\n\n\n  \u003c\/section\u003e\n\n\n  \u003c!-- =========================================================\n       FINAL PRODUCT STATEMENT\n       ========================================================= --\u003e\n\n  \u003csection class=\"product-final\"\u003e\n\n    \u003ch2\u003e\n      AccuraFil V-Bank Synthetic Air Filters\n    \u003c\/h2\u003e\n\n    \u003cp\u003e\n      AccuraFil V-Bank Synthetic Air Filters combine\n      \u003cstrong\u003ehigh-efficiency synthetic media, mini-pleat V-bank geometry,\n      rigid box construction, and a non-metallic ABS frame\u003c\/strong\u003e for\n      high-airflow commercial and industrial HVAC applications. Available\n      in MERV 11, MERV 13, MERV 14, and MERV 15 configurations, the design\n      provides efficient particulate filtration, turbulence-resistant\n      construction, moisture resistance, and fully incinerable\n      non-metallic disposal for compatible applications.\n    \u003c\/p\u003e\n\n  \u003c\/section\u003e\n\n\u003c\/div\u003e\n\n\n\u003cstyle\u003e\n\n  .accurafil-product-description {\n    max-width: 1200px;\n    margin: 0 auto;\n    color: #2d3748;\n    line-height: 1.7;\n    font-size: 16px;\n  }\n\n\n  .accurafil-product-description h2 {\n    color: #007b8c;\n    font-size: 30px;\n    line-height: 1.25;\n    margin: 0 0 20px;\n  }\n\n\n  .accurafil-product-description h3 {\n    color: #0f4c5c;\n    font-size: 20px;\n    line-height: 1.35;\n    margin: 0 0 10px;\n  }\n\n\n  .product-intro {\n    background: #f0fdfa;\n    border-left: 5px solid #00ced3;\n    padding: 30px;\n    margin-bottom: 35px;\n    border-radius: 10px;\n  }\n\n\n  .product-eyebrow {\n    color: #007b8c;\n    font-size: 13px;\n    font-weight: 700;\n    letter-spacing: .08em;\n    text-transform: uppercase;\n    margin: 0 0 10px;\n  }\n\n\n  .product-intro p {\n    margin: 0 0 15px;\n  }\n\n\n  .product-intro p:last-child {\n    margin-bottom: 0;\n  }\n\n\n  .product-section {\n    background: #ffffff;\n    padding: 30px;\n    margin-bottom: 30px;\n    border-radius: 14px;\n    box-shadow: 0 8px 24px rgba(0, 0, 0, .06);\n  }\n\n\n  .product-section p {\n    margin: 0 0 15px;\n  }\n\n\n  .product-section p:last-child {\n    margin-bottom: 0;\n  }\n\n\n  .benefits-grid {\n    display: grid;\n    grid-template-columns: repeat(2, minmax(0, 1fr));\n    gap: 20px;\n  }\n\n\n  .benefit-card,\n  .grade-selection-card,\n  .performance-card {\n    background: #f8fafc;\n    border: 1px solid #edf2f7;\n    border-radius: 10px;\n    padding: 22px;\n  }\n\n\n  .benefit-card p,\n  .grade-selection-card p,\n  .performance-card p {\n    margin: 0;\n    color: #4a5568;\n  }\n\n\n  .grade-selection-grid {\n    display: grid;\n    grid-template-columns: repeat(4, minmax(0, 1fr));\n    gap: 20px;\n    margin-top: 22px;\n  }\n\n\n  .grade-selection-card {\n    text-align: center;\n  }\n\n\n  .grade-selection-card h3 {\n    color: #007b8c;\n    font-size: 28px;\n    margin-bottom: 10px;\n  }\n\n\n  .grade-standard {\n    display: block;\n    color: #4a5568;\n    font-size: 12px;\n    font-weight: 700;\n    letter-spacing: .08em;\n    text-transform: uppercase;\n    margin-bottom: 7px;\n  }\n\n\n  .synthetic-callout {\n    display: flex;\n    align-items: flex-start;\n    gap: 20px;\n    background: linear-gradient(135deg, #1e293b 0%, #0f172a 100%);\n    border-radius: 10px;\n    padding: 24px;\n    margin-top: 24px;\n    color: #e2e8f0;\n  }\n\n\n  .synthetic-callout-icon {\n    flex-shrink: 0;\n    width: 54px;\n    height: 54px;\n    background: #97e6e6;\n    border-radius: 10px;\n    display: flex;\n    align-items: center;\n    justify-content: center;\n    font-size: 26px;\n  }\n\n\n  .synthetic-callout-body strong {\n    display: block;\n    font-size: 16px;\n    font-weight: 700;\n    color: #97e6e6;\n    margin-bottom: 6px;\n    text-transform: uppercase;\n    letter-spacing: .09em;\n  }\n\n\n  .synthetic-callout-body p {\n    font-size: 15px;\n    color: #94a3b8;\n    line-height: 1.6;\n    margin: 0;\n  }\n\n\n  .performance-grid {\n    display: grid;\n    grid-template-columns: repeat(2, minmax(0, 1fr));\n    gap: 20px;\n    margin-top: 22px;\n  }\n\n\n  .application-list {\n    margin: 15px 0 0;\n    padding-left: 22px;\n  }\n\n\n  .application-list li {\n    margin-bottom: 8px;\n  }\n\n\n  .howto-steps {\n    list-style: none;\n    display: flex;\n    flex-direction: column;\n    margin: 0;\n    padding: 0;\n  }\n\n\n  .howto-step {\n    display: flex;\n    gap: 18px;\n    align-items: flex-start;\n    padding: 20px 0;\n    border-bottom: 1px solid #edf2f7;\n  }\n\n\n  .howto-step:last-child {\n    border-bottom: none;\n  }\n\n\n  .step-number {\n    flex-shrink: 0;\n    width: 54px;\n    height: 54px;\n    background: #007b8c;\n    color: #ffffff;\n    border-radius: 50%;\n    display: flex;\n    align-items: center;\n    justify-content: center;\n    font-weight: 700;\n    font-size: 18px;\n  }\n\n\n  .step-content {\n    flex: 1;\n  }\n\n\n  .step-content h3 {\n    margin-bottom: 6px;\n  }\n\n\n  .step-content p {\n    color: #4a5568;\n    margin: 0;\n  }\n\n\n  .specifications-table-wrapper {\n    overflow-x: auto;\n  }\n\n\n  .specifications-table {\n    width: 100%;\n    border-collapse: collapse;\n  }\n\n\n  .specifications-table th,\n  .specifications-table td {\n    padding: 14px 16px;\n    border-bottom: 1px solid #edf2f7;\n    text-align: left;\n    vertical-align: top;\n  }\n\n\n  .specifications-table th {\n    width: 35%;\n    background: #f8fafc;\n    color: #4a5568;\n    font-weight: 700;\n  }\n\n\n  .procurement-section {\n    background: #f8fafc;\n  }\n\n\n  .faq-item {\n    border-bottom: 1px solid #edf2f7;\n    padding: 18px 0;\n  }\n\n\n  .faq-item:last-child {\n    border-bottom: 0;\n  }\n\n\n  .faq-item summary {\n    cursor: pointer;\n    color: #0f4c5c;\n    font-size: 18px;\n    font-weight: 700;\n    padding-right: 20px;\n  }\n\n\n  .faq-answer {\n    padding: 12px 0 0;\n    color: #4a5568;\n  }\n\n\n  .faq-answer p {\n    margin: 0;\n  }\n\n\n  .product-final {\n    background: #0f4c5c;\n    color: #ffffff;\n    padding: 35px;\n    border-radius: 14px;\n    margin-top: 35px;\n  }\n\n\n  .product-final h2 {\n    color: #ffffff;\n  }\n\n\n  .product-final p {\n    margin: 0;\n  }\n\n\n  @media (max-width: 1000px) {\n\n    .grade-selection-grid {\n      grid-template-columns: repeat(2, minmax(0, 1fr));\n    }\n\n  }\n\n\n  @media (max-width: 900px) {\n\n    .performance-grid {\n      grid-template-columns: 1fr;\n    }\n\n  }\n\n\n  @media (max-width: 768px) {\n\n    .accurafil-product-description {\n      font-size: 15px;\n    }\n\n    .accurafil-product-description h2 {\n      font-size: 25px;\n    }\n\n    .benefits-grid {\n      grid-template-columns: 1fr;\n    }\n\n    .grade-selection-grid {\n      grid-template-columns: 1fr;\n    }\n\n    .product-intro,\n    .product-section,\n    .product-final {\n      padding: 22px;\n    }\n\n    .specifications-table th,\n    .specifications-table td {\n      padding: 11px;\n    }\n\n    .synthetic-callout {\n      flex-direction: column;\n    }\n\n  }\n\n\u003c\/style\u003e","brand":"AccuraFil","offers":[{"title":"24 x 20 x 12 \/ MERV 15 \/ 4V","offer_id":48955351662900,"sku":"11-21-1810020-310-0","price":147.06,"currency_code":"USD","in_stock":true},{"title":"24 x 24 x 12 \/ MERV 15 \/ 4V","offer_id":48955351695668,"sku":"11-21-1840020-84-0","price":156.75,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0716\/7767\/3780\/files\/7.1FV-BankSyntheticAirFilter-1.jpg?v=1757294945"},{"product_id":"v-bank-microglass-air-filter-12x24x12","title":"V-Bank Microglass Air Filter – 12x24x12 – Pack of 2","description":"\u003cdiv class=\"accurafil-product-description\"\u003e\n\n  \u003c!-- =========================================================\n       PRODUCT INTRODUCTION\n       ========================================================= --\u003e\n\n  \u003csection class=\"product-intro\" aria-labelledby=\"product-description-heading\"\u003e\n\n    \u003cp class=\"product-eyebrow\"\u003e\n      High-Efficiency Glass Fiber HVAC Filtration\n    \u003c\/p\u003e\n\n    \u003ch2 id=\"product-description-heading\"\u003e\n      V-Bank Microglass Air Filter\n    \u003c\/h2\u003e\n\n    \u003cp\u003e\n      AccuraFil V-Bank Microglass Air Filters combine\n      \u003cstrong\u003emini-pleat glass fiber media with rigid V-bank construction\u003c\/strong\u003e\n      to provide high-efficiency particulate filtration with efficient\n      airflow and low resistance. The V-bank configuration increases the\n      effective media surface area within a compact filter footprint,\n      making the design suitable for high-airflow HVAC applications.\n    \u003c\/p\u003e\n\n    \u003cp\u003e\n      Available in \u003cstrong\u003eMERV 11, MERV 13, MERV 14, and MERV 15\u003c\/strong\u003e\n      configurations according to ASHRAE 52.2, corresponding to\n      \u003cstrong\u003eM6, F7, F8, and F9\u003c\/strong\u003e classifications under EN 779.\n      The filter uses synthetic glass fiber media with polyurethane potting,\n      thermoplastic bead separators, and a non-metallic ABS plastic frame\n      with a 20 mm header.\n    \u003c\/p\u003e\n\n    \u003cp\u003e\n      The fully incinerable construction is designed for compatible\n      pharmaceutical, healthcare, food processing, commercial, industrial,\n      VAV, air handler, and built-up filter bank applications where high\n      airflow, compact construction, and simplified filter disposal are\n      important considerations.\n    \u003c\/p\u003e\n\n  \u003c\/section\u003e\n\n\n  \u003c!-- =========================================================\n       KEY BENEFITS\n       ========================================================= --\u003e\n\n  \u003csection class=\"product-section\" aria-labelledby=\"key-benefits-heading\"\u003e\n\n    \u003ch2 id=\"key-benefits-heading\"\u003e\n      Key Benefits\n    \u003c\/h2\u003e\n\n    \u003cdiv class=\"benefits-grid\"\u003e\n\n      \u003carticle class=\"benefit-card\"\u003e\n\n        \u003ch3\u003e\n          High-Efficiency Microglass Media\n        \u003c\/h3\u003e\n\n        \u003cp\u003e\n          Synthetic glass fiber media provides high-efficiency particulate\n          filtration across MERV 11 through MERV 15 configurations.\n        \u003c\/p\u003e\n\n      \u003c\/article\u003e\n\n\n      \u003carticle class=\"benefit-card\"\u003e\n\n        \u003ch3\u003e\n          Mini-Pleat V-Bank Design\n        \u003c\/h3\u003e\n\n        \u003cp\u003e\n          The extended-surface mini-pleat configuration increases effective\n          media area within a compact rigid V-bank filter footprint.\n        \u003c\/p\u003e\n\n      \u003c\/article\u003e\n\n\n      \u003carticle class=\"benefit-card\"\u003e\n\n        \u003ch3\u003e\n          Polyurethane-Potted Media Pack\n        \u003c\/h3\u003e\n\n        \u003cp\u003e\n          Polyurethane potting bonds the media pack to the frame and provides\n          enhanced burst resistance for demanding airflow conditions.\n        \u003c\/p\u003e\n\n      \u003c\/article\u003e\n\n\n      \u003carticle class=\"benefit-card\"\u003e\n\n        \u003ch3\u003e\n          Fully Incinerable Construction\n        \u003c\/h3\u003e\n\n        \u003cp\u003e\n          Non-metallic filter construction supports simplified end-of-life\n          disposal in facilities where incineration is required or preferred.\n        \u003c\/p\u003e\n\n      \u003c\/article\u003e\n\n    \u003c\/div\u003e\n\n  \u003c\/section\u003e\n\n\n  \u003c!-- =========================================================\n       TECHNICAL SPECIFICATIONS\n       ========================================================= --\u003e\n\n  \u003csection class=\"product-section\" aria-labelledby=\"specifications-heading\"\u003e\n\n    \u003ch2 id=\"specifications-heading\"\u003e\n      Technical Specifications\n    \u003c\/h2\u003e\n\n    \u003cdiv class=\"specifications-table-wrapper\"\u003e\n\n      \u003ctable class=\"specifications-table\"\u003e\n\n        \u003ctbody\u003e\n\n          \u003ctr\u003e\n            \u003cth scope=\"row\"\u003e\n              Filter Type\n            \u003c\/th\u003e\n\n            \u003ctd\u003e\n              V-Bank Rigid Box Filter\n            \u003c\/td\u003e\n          \u003c\/tr\u003e\n\n\n          \u003ctr\u003e\n            \u003cth scope=\"row\"\u003e\n              Filter Design\n            \u003c\/th\u003e\n\n            \u003ctd\u003e\n              Mini-Pleat V-Bank Configuration\n            \u003c\/td\u003e\n          \u003c\/tr\u003e\n\n\n          \u003ctr\u003e\n            \u003cth scope=\"row\"\u003e\n              MERV Efficiency\n            \u003c\/th\u003e\n\n            \u003ctd\u003e\n              MERV 11 \/ MERV 14 \/ MERV 15\n            \u003c\/td\u003e\n          \u003c\/tr\u003e\n\n\n          \u003ctr\u003e\n            \u003cth scope=\"row\"\u003e\n              EN 779 Grades\n            \u003c\/th\u003e\n\n            \u003ctd\u003e\n              M6 \/ F8 \/ F9\n            \u003c\/td\u003e\n          \u003c\/tr\u003e\n\n\n          \u003ctr\u003e\n            \u003cth scope=\"row\"\u003e\n              Filtration Standard\n            \u003c\/th\u003e\n\n            \u003ctd\u003e\n              ASHRAE 52.2\n            \u003c\/td\u003e\n          \u003c\/tr\u003e\n\n\n          \u003ctr\u003e\n            \u003cth scope=\"row\"\u003e\n              Filter Media\n            \u003c\/th\u003e\n\n            \u003ctd\u003e\n              Synthetic Glass Fiber Media\n            \u003c\/td\u003e\n          \u003c\/tr\u003e\n\n\n          \u003ctr\u003e\n            \u003cth scope=\"row\"\u003e\n              Media Bonding\n            \u003c\/th\u003e\n\n            \u003ctd\u003e\n              Polyurethane Potting\n            \u003c\/td\u003e\n          \u003c\/tr\u003e\n\n\n          \u003ctr\u003e\n            \u003cth scope=\"row\"\u003e\n              Media Separator\n            \u003c\/th\u003e\n\n            \u003ctd\u003e\n              Thermoplastic Bead Separators (Hot Melt Beads)\n            \u003c\/td\u003e\n          \u003c\/tr\u003e\n\n\n          \u003ctr\u003e\n            \u003cth scope=\"row\"\u003e\n              Frame Material\n            \u003c\/th\u003e\n\n            \u003ctd\u003e\n              ABS Plastic — Non-Metallic\n            \u003c\/td\u003e\n          \u003c\/tr\u003e\n\n\n          \u003ctr\u003e\n            \u003cth scope=\"row\"\u003e\n              Header Construction\n            \u003c\/th\u003e\n\n            \u003ctd\u003e\n              20 mm Header\n            \u003c\/td\u003e\n          \u003c\/tr\u003e\n\n\n          \u003ctr\u003e\n            \u003cth scope=\"row\"\u003e\n              Maximum Operating Velocity\n            \u003c\/th\u003e\n\n            \u003ctd\u003e\n              625 fpm \/ 3.175 m\/s\n            \u003c\/td\u003e\n          \u003c\/tr\u003e\n\n\n          \u003ctr\u003e\n            \u003cth scope=\"row\"\u003e\n              Maximum Operating Temperature\n            \u003c\/th\u003e\n\n            \u003ctd\u003e\n              176°F (80°C)\n            \u003c\/td\u003e\n          \u003c\/tr\u003e\n\n\n          \u003ctr\u003e\n            \u003cth scope=\"row\"\u003e\n              Final Pressure Drop\n            \u003c\/th\u003e\n\n            \u003ctd\u003e\n              1.50\" w.g.\n            \u003c\/td\u003e\n          \u003c\/tr\u003e\n\n\n          \u003ctr\u003e\n            \u003cth scope=\"row\"\u003e\n              Maximum Recommended Pressure Drop\n            \u003c\/th\u003e\n\n            \u003ctd\u003e\n              2.00\" w.g.\n            \u003c\/td\u003e\n          \u003c\/tr\u003e\n\n\n          \u003ctr\u003e\n            \u003cth scope=\"row\"\u003e\n              Disposal\n            \u003c\/th\u003e\n\n            \u003ctd\u003e\n              Fully Incinerable, Non-Metallic Construction\n            \u003c\/td\u003e\n          \u003c\/tr\u003e\n\u003ctr\u003e\n            \u003cth scope=\"row\"\u003e\n              Fire Classification\n            \u003c\/th\u003e\n\n            \u003ctd\u003e\n              UL900 Classified\n            \u003c\/td\u003e\n        \u003c\/tr\u003e\n\u003c\/tbody\u003e\n\n      \u003c\/table\u003e\n\n    \u003c\/div\u003e\n\n  \u003c\/section\u003e\n\n\n  \u003c!-- =========================================================\n       MICROGLASS PERFORMANCE\n       ========================================================= --\u003e\n\n  \u003csection class=\"product-section\" aria-labelledby=\"microglass-performance-heading\"\u003e\n\n    \u003ch2 id=\"microglass-performance-heading\"\u003e\n      Glass Fiber Media \u0026amp; Mini-Pleat Performance\n    \u003c\/h2\u003e\n\n    \u003cp\u003e\n      The V-Bank Microglass Filter uses\n      \u003cstrong\u003esynthetic glass fiber media\u003c\/strong\u003e arranged in a mini-pleat\n      configuration to provide a large effective filtration area within\n      a compact rigid filter design. The increased media area helps distribute\n      airflow across the filter while supporting the selected MERV efficiency.\n    \u003c\/p\u003e\n\n    \u003cp\u003e\n      Polyurethane potting secures the media pack within the frame and provides\n      enhanced burst resistance for demanding airflow applications. The\n      combination of mini-pleat geometry, rigid V-bank construction, and\n      potted media is intended to provide consistent filter performance in\n      compatible HVAC systems.\n    \u003c\/p\u003e\n\n    \u003cdiv class=\"carbon-callout\"\u003e\n\n      \u003cdiv class=\"carbon-callout-icon\" aria-hidden=\"true\"\u003e\n        🔬\n      \u003c\/div\u003e\n\n      \u003cdiv class=\"carbon-callout-body\"\u003e\n\n        \u003cstrong\u003e\n          High-Strength Glass Fiber Media\n        \u003c\/strong\u003e\n\n        \u003cp\u003e\n          Synthetic glass fiber media combined with polyurethane potting\n          provides a rigid, durable media pack designed for high-airflow\n          HVAC applications and demanding installation environments.\n        \u003c\/p\u003e\n\n      \u003c\/div\u003e\n\n    \u003c\/div\u003e\n\n  \u003c\/section\u003e\n\n\n  \u003c!-- =========================================================\n       FILTER GRADE SELECTION\n       ========================================================= --\u003e\n\n  \u003csection class=\"product-section\" aria-labelledby=\"merv-selection-heading\"\u003e\n\n    \u003ch2 id=\"merv-selection-heading\"\u003e\n      Choosing the Right MERV Rating\n    \u003c\/h2\u003e\n\n    \u003cp\u003e\n      Select the appropriate MERV efficiency based on the required particulate\n      filtration level, facility application, airflow requirements, and HVAC\n      system pressure-drop limitations.\n    \u003c\/p\u003e\n\n    \u003cdiv class=\"merv-selection-grid\"\u003e\n\n      \u003carticle class=\"merv-selection-card\"\u003e\n\n        \u003ch3\u003e\n          MERV 11\n        \u003c\/h3\u003e\n\n        \u003cp\u003e\n          Suitable for general commercial ventilation and HVAC applications\n          requiring enhanced particulate filtration.\n        \u003c\/p\u003e\n\n      \u003c\/article\u003e\n\n\n      \u003carticle class=\"merv-selection-card\"\u003e\n\n        \u003ch3\u003e\n          MERV 13\n        \u003c\/h3\u003e\n\n        \u003cp\u003e\n          Provides higher-efficiency particulate filtration for offices,\n          hotels, light healthcare, and commercial HVAC applications.\n        \u003c\/p\u003e\n\n      \u003c\/article\u003e\n\n\n      \u003carticle class=\"merv-selection-card\"\u003e\n\n        \u003ch3\u003e\n          MERV 14\n        \u003c\/h3\u003e\n\n        \u003cp\u003e\n          Higher-efficiency filtration for hospitals, laboratories, LEED\n          buildings, and other applications requiring increased particulate\n          control.\n        \u003c\/p\u003e\n\n      \u003c\/article\u003e\n\n\n      \u003carticle class=\"merv-selection-card\"\u003e\n\n        \u003ch3\u003e\n          MERV 15\n        \u003c\/h3\u003e\n\n        \u003cp\u003e\n          High-efficiency particulate filtration for demanding applications\n          including pharmaceutical, controlled-environment, and critical\n          HVAC systems.\n        \u003c\/p\u003e\n\n      \u003c\/article\u003e\n\n    \u003c\/div\u003e\n\n  \u003c\/section\u003e\n\n\n  \u003c!-- =========================================================\n       V-BANK DESIGN\n       ========================================================= --\u003e\n\n  \u003csection class=\"product-section\" aria-labelledby=\"vbank-design-heading\"\u003e\n\n    \u003ch2 id=\"vbank-design-heading\"\u003e\n      V-Bank Mini-Pleat Design for High Airflow\n    \u003c\/h2\u003e\n\n    \u003cp\u003e\n      The V-bank configuration arranges multiple angled media sections within\n      the rigid filter frame, increasing the effective filtration surface area\n      compared with a flat filter occupying the same general footprint.\n      The mini-pleat construction allows a large amount of filtration media\n      to be incorporated into a compact filter design.\n    \u003c\/p\u003e\n\n    \u003cp\u003e\n      This extended-surface configuration is designed to support\n      \u003cstrong\u003ehigh airflow and low resistance\u003c\/strong\u003e while maintaining the\n      structural advantages of a rigid box-style filter. The maximum\n      recommended operating velocity is \u003cstrong\u003e625 fpm (3.175 m\/s)\u003c\/strong\u003e.\n    \u003c\/p\u003e\n\n  \u003c\/section\u003e\n\n\n  \u003c!-- =========================================================\n       FILTER GRADE TIER PANEL\n       ========================================================= --\u003e\n\n  \u003csection class=\"product-section\" aria-labelledby=\"grade-tiers-heading\"\u003e\n\n    \u003ch2 id=\"grade-tiers-heading\"\u003e\n      MERV \u0026amp; EN 779 Filter Grade Tiers\n    \u003c\/h2\u003e\n\n    \u003cdiv class=\"grade-grid\" role=\"list\" aria-label=\"Available filter grade tiers\"\u003e\n\n      \u003carticle class=\"grade-tier grade-tier-m6\" role=\"listitem\"\u003e\n\n        \u003cspan class=\"grade-en\"\u003e\n          EN 779: M6\n        \u003c\/span\u003e\n\n        \u003cspan class=\"grade-merv\"\u003e\n          MERV 11\n        \u003c\/span\u003e\n\n        \u003cspan class=\"grade-label\"\u003e\n          General commercial ventilation\n        \u003c\/span\u003e\n\n      \u003c\/article\u003e\n\n\n      \u003carticle class=\"grade-tier grade-tier-f7\" role=\"listitem\"\u003e\n\n        \u003cspan class=\"grade-en\"\u003e\n          EN 779: F7\n        \u003c\/span\u003e\n\n        \u003cspan class=\"grade-merv\"\u003e\n          MERV 13\n        \u003c\/span\u003e\n\n        \u003cspan class=\"grade-label\"\u003e\n          Offices, hotels \u0026amp; light healthcare\n        \u003c\/span\u003e\n\n      \u003c\/article\u003e\n\n\n      \u003carticle class=\"grade-tier grade-tier-f8\" role=\"listitem\"\u003e\n\n        \u003cspan class=\"grade-en\"\u003e\n          EN 779: F8\n        \u003c\/span\u003e\n\n        \u003cspan class=\"grade-merv\"\u003e\n          MERV 14\n        \u003c\/span\u003e\n\n        \u003cspan class=\"grade-label\"\u003e\n          Hospitals, laboratories \u0026amp; LEED buildings\n        \u003c\/span\u003e\n\n      \u003c\/article\u003e\n\n\n      \u003carticle class=\"grade-tier grade-tier-f9\" role=\"listitem\"\u003e\n\n        \u003cspan class=\"grade-en\"\u003e\n          EN 779: F9\n        \u003c\/span\u003e\n\n        \u003cspan class=\"grade-merv\"\u003e\n          MERV 15\n        \u003c\/span\u003e\n\n        \u003cspan class=\"grade-label\"\u003e\n          Pharmaceutical, cleanroom \u0026amp; critical applications\n        \u003c\/span\u003e\n\n      \u003c\/article\u003e\n\n    \u003c\/div\u003e\n\n  \u003c\/section\u003e\n\n\n  \u003c!-- =========================================================\n       FRAME \u0026 HEADER\n       ========================================================= --\u003e\n\n  \u003csection class=\"product-section\" aria-labelledby=\"frame-heading\"\u003e\n\n    \u003ch2 id=\"frame-heading\"\u003e\n      ABS Frame \u0026amp; 20 mm Header Construction\n    \u003c\/h2\u003e\n\n    \u003cp\u003e\n      The V-Bank Microglass Filter uses a\n      \u003cstrong\u003enon-metallic ABS plastic frame\u003c\/strong\u003e with a 20 mm header.\n      The rigid frame provides structural support for the mini-pleat media\n      pack while maintaining the compact V-bank configuration.\n    \u003c\/p\u003e\n\n    \u003cp\u003e\n      The non-metallic construction contributes to the filter's\n      \u003cstrong\u003efully incinerable design\u003c\/strong\u003e, allowing the filter to be\n      considered for applications where simplified disposal is important.\n    \u003c\/p\u003e\n\n    \u003cp\u003e\n      Always verify the existing HVAC housing, filter bank dimensions, header\n      configuration, sealing arrangement, and installation requirements\n      before ordering a replacement filter.\n    \u003c\/p\u003e\n\n  \u003c\/section\u003e\n\n\n  \u003c!-- =========================================================\n       DISPOSAL \/ INCINERATION\n       ========================================================= --\u003e\n\n  \u003csection class=\"product-section\" aria-labelledby=\"disposal-heading\"\u003e\n\n    \u003ch2 id=\"disposal-heading\"\u003e\n      Fully Incinerable Non-Metallic Construction\n    \u003c\/h2\u003e\n\n    \u003cp\u003e\n      The V-Bank Microglass Filter is constructed without conventional\n      metallic separators, using a non-metallic ABS frame and thermoplastic\n      bead separators. This construction is designed to allow the complete\n      filter assembly to be incinerated without requiring separation of\n      metallic filter components.\n    \u003c\/p\u003e\n\n    \u003cp\u003e\n      Fully incinerable construction can simplify end-of-life handling for\n      facilities where spent filters require controlled disposal, including\n      compatible pharmaceutical, healthcare, food processing, and other\n      specialized environments.\n    \u003c\/p\u003e\n\n  \u003c\/section\u003e\n\n\n  \u003c!-- =========================================================\n       INDUSTRY APPLICATIONS\n       ========================================================= --\u003e\n\n  \u003csection class=\"product-section\" aria-labelledby=\"applications-heading\"\u003e\n\n    \u003ch2 id=\"applications-heading\"\u003e\n      Commercial \u0026amp; Industrial HVAC Applications\n    \u003c\/h2\u003e\n\n    \u003cp\u003e\n      AccuraFil V-Bank Microglass Filters are designed for applications\n      requiring high-efficiency particulate filtration, extended media\n      surface area, and a compact rigid V-bank configuration, including:\n    \u003c\/p\u003e\n\n    \u003cul class=\"application-list\"\u003e\n\n      \u003cli\u003e\n        Hospitals and healthcare facilities\n      \u003c\/li\u003e\n\n      \u003cli\u003e\n        Pharmaceutical and biotechnology facilities\n      \u003c\/li\u003e\n\n      \u003cli\u003e\n        ISO cleanroom and controlled environments\n      \u003c\/li\u003e\n\n      \u003cli\u003e\n        Commercial office buildings\n      \u003c\/li\u003e\n\n      \u003cli\u003e\n        Data centers and mission-critical facilities\n      \u003c\/li\u003e\n\n      \u003cli\u003e\n        Food and beverage processing facilities\n      \u003c\/li\u003e\n\n      \u003cli\u003e\n        Air handling units and packaged HVAC systems\n      \u003c\/li\u003e\n\n      \u003cli\u003e\n        Variable Air Volume (VAV) systems\n      \u003c\/li\u003e\n\n      \u003cli\u003e\n        Built-up filter banks and multi-cell filtration systems\n      \u003c\/li\u003e\n\n      \u003cli\u003e\n        Industrial HVAC applications requiring compact high-efficiency filtration\n      \u003c\/li\u003e\n\n    \u003c\/ul\u003e\n\n  \u003c\/section\u003e\n\n\n  \u003c!-- =========================================================\n       HIGH-DEMAND ENVIRONMENTS\n       ========================================================= --\u003e\n\n  \u003csection class=\"product-section\" aria-labelledby=\"high-demand-heading\"\u003e\n\n    \u003ch2 id=\"high-demand-heading\"\u003e\n      Reliable Performance in High-Demand Environments\n    \u003c\/h2\u003e\n\n    \u003cp\u003e\n      The rigid V-bank construction, glass fiber media, and polyurethane-potted\n      media pack make this filter suitable for HVAC applications requiring\n      consistent particulate filtration under demanding airflow conditions.\n    \u003c\/p\u003e\n\n\n    \u003ch3\u003e\n      Hospitals \u0026amp; Healthcare\n    \u003c\/h3\u003e\n\n    \u003cp\u003e\n      Higher-efficiency MERV configurations provide particulate filtration\n      for compatible healthcare HVAC applications. The fully incinerable\n      construction can also simplify disposal of spent filters where\n      controlled disposal procedures are required.\n    \u003c\/p\u003e\n\n\n    \u003ch3\u003e\n      Pharmaceutical \u0026amp; Cleanroom Applications\n    \u003c\/h3\u003e\n\n    \u003cp\u003e\n      MERV 14 and MERV 15 configurations provide high-efficiency particulate\n      filtration for compatible controlled environments. Non-metallic,\n      incinerable construction can support facilities where filter disposal\n      procedures are an important consideration.\n    \u003c\/p\u003e\n\n\n    \u003ch3\u003e\n      Commercial \u0026amp; Office Buildings\n    \u003c\/h3\u003e\n\n    \u003cp\u003e\n      MERV 11 through MERV 14 configurations provide a range of particulate\n      filtration options for commercial HVAC systems where efficient airflow\n      and compact filter construction are important.\n    \u003c\/p\u003e\n\n\n    \u003ch3\u003e\n      VAV \u0026amp; Air Handling Systems\n    \u003c\/h3\u003e\n\n    \u003cp\u003e\n      The rigid V-bank construction and polyurethane-potted media pack are\n      designed for demanding air handler and variable-airflow applications\n      where maintaining structural integrity is important.\n    \u003c\/p\u003e\n\n\n    \u003ch3\u003e\n      Food Processing Facilities\n    \u003c\/h3\u003e\n\n    \u003cp\u003e\n      Non-metallic and fully incinerable construction can be advantageous\n      for compatible food-processing HVAC applications where simplified\n      end-of-life disposal is important.\n    \u003c\/p\u003e\n\n  \u003c\/section\u003e\n\n\n  \u003c!-- =========================================================\n       DUAL PERFORMANCE\n       ========================================================= --\u003e\n\n  \u003csection class=\"product-section\" aria-labelledby=\"performance-heading\"\u003e\n\n    \u003ch2 id=\"performance-heading\"\u003e\n      High-Efficiency Particulate Filtration Performance\n    \u003c\/h2\u003e\n\n    \u003cdiv class=\"benefits-grid\"\u003e\n\n      \u003carticle class=\"benefit-card\"\u003e\n\n        \u003ch3\u003e\n          High-Efficiency Particle Capture\n        \u003c\/h3\u003e\n\n        \u003cp\u003e\n          Available from MERV 11 through MERV 15 to accommodate different\n          particulate filtration requirements.\n        \u003c\/p\u003e\n\n      \u003c\/article\u003e\n\n\n      \u003carticle class=\"benefit-card\"\u003e\n\n        \u003ch3\u003e\n          Large Effective Media Area\n        \u003c\/h3\u003e\n\n        \u003cp\u003e\n          Mini-pleat V-bank geometry increases effective media surface area\n          within a compact rigid filter configuration.\n        \u003c\/p\u003e\n\n      \u003c\/article\u003e\n\n\n      \u003carticle class=\"benefit-card\"\u003e\n\n        \u003ch3\u003e\n          Enhanced Media Integrity\n        \u003c\/h3\u003e\n\n        \u003cp\u003e\n          Polyurethane potting secures the glass fiber media pack within\n          the frame and provides enhanced burst resistance.\n        \u003c\/p\u003e\n\n      \u003c\/article\u003e\n\n\n      \u003carticle class=\"benefit-card\"\u003e\n\n        \u003ch3\u003e\n          Simplified Disposal\n        \u003c\/h3\u003e\n\n        \u003cp\u003e\n          Non-metallic construction and thermoplastic bead separators support\n          fully incinerable filter disposal without component separation.\n        \u003c\/p\u003e\n\n      \u003c\/article\u003e\n\n    \u003c\/div\u003e\n\n  \u003c\/section\u003e\n\n\n  \u003c!-- =========================================================\n       SELECTION GUIDE\n       ========================================================= --\u003e\n\n  \u003csection class=\"product-section\" aria-labelledby=\"selection-guide-heading\"\u003e\n\n    \u003ch2 id=\"selection-guide-heading\"\u003e\n      How to Select the Right V-Bank Microglass Filter\n    \u003c\/h2\u003e\n\n    \u003col class=\"howto-steps\"\u003e\n\n      \u003cli class=\"howto-step\"\u003e\n\n        \u003cspan class=\"step-number\" aria-hidden=\"true\"\u003e\n          1\n        \u003c\/span\u003e\n\n        \u003cdiv class=\"step-content\"\u003e\n\n          \u003ch3\u003e\n            Select the Required MERV Rating\n          \u003c\/h3\u003e\n\n          \u003cp\u003e\n            Choose MERV 11 for general commercial ventilation. Choose\n            MERV 13 for offices, hotels, and light healthcare applications.\n            Choose MERV 14 for hospitals, laboratories, and higher-efficiency\n            HVAC applications. Choose MERV 15 for pharmaceutical, cleanroom,\n            and other critical environments requiring high-efficiency\n            particulate filtration.\n          \u003c\/p\u003e\n\n        \u003c\/div\u003e\n\n      \u003c\/li\u003e\n\n\n      \u003cli class=\"howto-step\"\u003e\n\n        \u003cspan class=\"step-number\" aria-hidden=\"true\"\u003e\n          2\n        \u003c\/span\u003e\n\n        \u003cdiv class=\"step-content\"\u003e\n\n          \u003ch3\u003e\n            Verify Airflow \u0026amp; Pressure-Drop Requirements\n          \u003c\/h3\u003e\n\n          \u003cp\u003e\n            Confirm that system airflow does not exceed the specified maximum\n            operating velocity of \u003cstrong\u003e625 fpm \/ 3.175 m\/s\u003c\/strong\u003e.\n            Verify that the HVAC system can accommodate the specified\n            pressure-drop conditions, including the 1.50\" w.g. final\n            pressure drop and 2.00\" w.g. maximum recommended pressure drop.\n          \u003c\/p\u003e\n\n        \u003c\/div\u003e\n\n      \u003c\/li\u003e\n\n\n      \u003cli class=\"howto-step\"\u003e\n\n        \u003cspan class=\"step-number\" aria-hidden=\"true\"\u003e\n          3\n        \u003c\/span\u003e\n\n        \u003cdiv class=\"step-content\"\u003e\n\n          \u003ch3\u003e\n            Confirm Housing Compatibility\n          \u003c\/h3\u003e\n\n          \u003cp\u003e\n            Verify the actual filter face dimensions, housing depth,\n            header configuration, sealing arrangement, and installation\n            orientation before ordering. The specified configuration uses\n            an ABS plastic frame with a 20 mm header.\n          \u003c\/p\u003e\n\n        \u003c\/div\u003e\n\n      \u003c\/li\u003e\n\n\n      \u003cli class=\"howto-step\"\u003e\n\n        \u003cspan class=\"step-number\" aria-hidden=\"true\"\u003e\n          4\n        \u003c\/span\u003e\n\n        \u003cdiv class=\"step-content\"\u003e\n\n          \u003ch3\u003e\n            Confirm Temperature \u0026amp; Disposal Requirements\n          \u003c\/h3\u003e\n\n          \u003cp\u003e\n            Confirm that operating temperature does not exceed\n            \u003cstrong\u003e176°F (80°C)\u003c\/strong\u003e. Where filter incineration is\n            required or preferred, verify that the facility's disposal\n            procedures are compatible with fully incinerable filter\n            construction.\n          \u003c\/p\u003e\n\n        \u003c\/div\u003e\n\n      \u003c\/li\u003e\n\n    \u003c\/ol\u003e\n\n  \u003c\/section\u003e\n\n\n  \u003c!-- =========================================================\n       PRODUCT COMPARISON\n       ========================================================= --\u003e\n\n  \u003csection class=\"product-section\" aria-labelledby=\"comparison-heading\"\u003e\n\n    \u003ch2 id=\"comparison-heading\"\u003e\n      V-Bank Microglass Filter vs. Bag \u0026amp; Standard Box Filters\n    \u003c\/h2\u003e\n\n    \u003cp\u003e\n      Compared with conventional \u003cstrong\u003ebag-style filters\u003c\/strong\u003e, the\n      rigid V-bank design provides a fixed filter geometry rather than a\n      flexible pocket configuration. The mini-pleat glass fiber construction\n      provides a large effective media area within the rigid housing format,\n      making the design suitable for systems where compact construction and\n      high airflow are important.\n    \u003c\/p\u003e\n\n    \u003cp\u003e\n      Compared with conventional\n      \u003cstrong\u003estandard box-type pleated filters\u003c\/strong\u003e, the V-bank\n      configuration allows more effective media area to be incorporated\n      within the filter footprint. The polyurethane-potted media pack and\n      thermoplastic bead separators also provide structural support for the\n      pleated media during operation.\n    \u003c\/p\u003e\n\n    \u003cp\u003e\n      The best filter configuration depends on required MERV efficiency,\n      airflow, available installation depth, pressure-drop limitations,\n      housing dimensions, and facility disposal requirements.\n    \u003c\/p\u003e\n\n  \u003c\/section\u003e\n\n\n  \u003c!-- =========================================================\n       PRODUCT SELECTION \u0026 PROCUREMENT\n       ========================================================= --\u003e\n\n  \u003csection class=\"product-section procurement-section\" aria-labelledby=\"procurement-heading\"\u003e\n\n    \u003ch2 id=\"procurement-heading\"\u003e\n      Product Selection \u0026amp; Procurement\n    \u003c\/h2\u003e\n\n    \u003cp\u003e\n      Before ordering a replacement V-Bank Microglass Filter, verify the\n      \u003cstrong\u003eactual filter dimensions\u003c\/strong\u003e, required MERV rating,\n      filter depth, frame and header configuration, airflow requirements,\n      maximum operating velocity, pressure-drop limitations, and compatibility\n      with the existing HVAC housing or filter bank.\n    \u003c\/p\u003e\n\n    \u003cp\u003e\n      Do not select a replacement filter based only on the nominal size printed\n      on an existing filter. Confirm the physical dimensions and housing\n      configuration to reduce the risk of installation problems, poor fit,\n      inadequate sealing, return shipping expenses, restocking charges,\n      and project delays.\n    \u003c\/p\u003e\n\n    \u003cp\u003e\n      AccuraFil supplies commercial and industrial air filtration products\n      for facility managers, HVAC contractors, mechanical engineers,\n      healthcare organizations, pharmaceutical facilities, data center\n      operators, and procurement teams.\n    \u003c\/p\u003e\n\n  \u003c\/section\u003e\n\n\n  \u003c!-- =========================================================\n       FAQ\n       ========================================================= --\u003e\n\n  \u003csection class=\"product-section\" aria-labelledby=\"faq-heading\"\u003e\n\n    \u003ch2 id=\"faq-heading\"\u003e\n      Frequently Asked Questions\n    \u003c\/h2\u003e\n\n\n    \u003cdetails class=\"faq-item\"\u003e\n\n      \u003csummary\u003e\n        What is a V-Bank Microglass Filter?\n      \u003c\/summary\u003e\n\n      \u003cdiv class=\"faq-answer\"\u003e\n\n        \u003cp\u003e\n          A V-Bank Microglass Filter is a rigid box-style HVAC filter that\n          uses glass fiber media arranged in a V-shaped mini-pleat\n          configuration. The design increases effective media surface area\n          within a compact filter footprint and is intended for high-efficiency\n          particulate filtration applications.\n        \u003c\/p\u003e\n\n      \u003c\/div\u003e\n\n    \u003c\/details\u003e\n\n\n    \u003cdetails class=\"faq-item\"\u003e\n\n      \u003csummary\u003e\n        What MERV ratings are available?\n      \u003c\/summary\u003e\n\n      \u003cdiv class=\"faq-answer\"\u003e\n\n        \u003cp\u003e\n          The AccuraFil V-Bank Microglass Filter is available in\n          \u003cstrong\u003eMERV 11, MERV 13, MERV 14, and MERV 15\u003c\/strong\u003e according\n          to the supplied product specifications. These correspond to\n          M6, F7, F8, and F9 classifications under EN 779.\n        \u003c\/p\u003e\n\n      \u003c\/div\u003e\n\n    \u003c\/details\u003e\n\n\n    \u003cdetails class=\"faq-item\"\u003e\n\n      \u003csummary\u003e\n        What type of filter media does it use?\n      \u003c\/summary\u003e\n\n      \u003cdiv class=\"faq-answer\"\u003e\n\n        \u003cp\u003e\n          The filter uses synthetic glass fiber media. The media pack is\n          secured using polyurethane potting and incorporates thermoplastic\n          bead separators to maintain pleat spacing.\n        \u003c\/p\u003e\n\n      \u003c\/div\u003e\n\n    \u003c\/details\u003e\n\n\n    \u003cdetails class=\"faq-item\"\u003e\n\n      \u003csummary\u003e\n        What is the advantage of the mini-pleat V-bank design?\n      \u003c\/summary\u003e\n\n      \u003cdiv class=\"faq-answer\"\u003e\n\n        \u003cp\u003e\n          The mini-pleat V-bank configuration increases effective media\n          surface area within a compact rigid filter footprint. This design\n          is intended to support high airflow and efficient particulate\n          filtration while maintaining a rigid filter structure.\n        \u003c\/p\u003e\n\n      \u003c\/div\u003e\n\n    \u003c\/details\u003e\n\n\n    \u003cdetails class=\"faq-item\"\u003e\n\n      \u003csummary\u003e\n        What are thermoplastic bead separators?\n      \u003c\/summary\u003e\n\n      \u003cdiv class=\"faq-answer\"\u003e\n\n        \u003cp\u003e\n          Thermoplastic bead separators, also called hot melt beads, are\n          non-metallic separator elements used to maintain consistent pleat\n          spacing throughout the media pack.\n        \u003c\/p\u003e\n\n      \u003c\/div\u003e\n\n    \u003c\/details\u003e\n\n\n    \u003cdetails class=\"faq-item\"\u003e\n\n      \u003csummary\u003e\n        Is the V-Bank Microglass Filter fully incinerable?\n      \u003c\/summary\u003e\n\n      \u003cdiv class=\"faq-answer\"\u003e\n\n        \u003cp\u003e\n          The supplied product specifications identify the filter as\n          \u003cstrong\u003efully incinerable and non-metallic\u003c\/strong\u003e. This\n          construction is designed to simplify end-of-life disposal where\n          facility procedures call for filter incineration.\n        \u003c\/p\u003e\n\n      \u003c\/div\u003e\n\n    \u003c\/details\u003e\n\n\n    \u003cdetails class=\"faq-item\"\u003e\n\n      \u003csummary\u003e\n        What is the maximum operating velocity?\n      \u003c\/summary\u003e\n\n      \u003cdiv class=\"faq-answer\"\u003e\n\n        \u003cp\u003e\n          The specified maximum operating velocity is\n          \u003cstrong\u003e625 fpm (3.175 m\/s)\u003c\/strong\u003e. HVAC system operating\n          conditions should be verified before installation.\n        \u003c\/p\u003e\n\n      \u003c\/div\u003e\n\n    \u003c\/details\u003e\n\n\n    \u003cdetails class=\"faq-item\"\u003e\n\n      \u003csummary\u003e\n        What is the maximum operating temperature?\n      \u003c\/summary\u003e\n\n      \u003cdiv class=\"faq-answer\"\u003e\n\n        \u003cp\u003e\n          The specified maximum operating temperature is\n          \u003cstrong\u003e176°F (80°C)\u003c\/strong\u003e.\n        \u003c\/p\u003e\n\n      \u003c\/div\u003e\n\n    \u003c\/details\u003e\n\n\n    \u003cdetails class=\"faq-item\"\u003e\n\n      \u003csummary\u003e\n        What frame and header does the filter use?\n      \u003c\/summary\u003e\n\n      \u003cdiv class=\"faq-answer\"\u003e\n\n        \u003cp\u003e\n          The specified configuration uses a\n          \u003cstrong\u003enon-metallic ABS plastic frame with a 20 mm header\u003c\/strong\u003e.\n          Housing compatibility should be verified before ordering.\n        \u003c\/p\u003e\n\n      \u003c\/div\u003e\n\n    \u003c\/details\u003e\n\n\n    \u003cdetails class=\"faq-item\"\u003e\n\n      \u003csummary\u003e\n        What should I verify before ordering a replacement?\n      \u003c\/summary\u003e\n\n      \u003cdiv class=\"faq-answer\"\u003e\n\n        \u003cp\u003e\n          Verify the actual filter dimensions, MERV rating, filter depth,\n          frame and header configuration, housing dimensions, sealing\n          arrangement, airflow requirements, and pressure-drop limitations.\n          Matching the physical filter and housing configuration helps avoid\n          fit problems, return shipping charges, restocking fees, and delays.\n        \u003c\/p\u003e\n\n      \u003c\/div\u003e\n\n    \u003c\/details\u003e\n\n\n  \u003c\/section\u003e\n\n\n  \u003c!-- =========================================================\n       FINAL PRODUCT STATEMENT\n       ========================================================= --\u003e\n\n  \u003csection class=\"product-final\"\u003e\n\n    \u003ch2\u003e\n      AccuraFil V-Bank Microglass Air Filters\n    \u003c\/h2\u003e\n\n    \u003cp\u003e\n      AccuraFil V-Bank Microglass Air Filters combine\n      \u003cstrong\u003esynthetic glass fiber media, mini-pleat V-bank construction,\n      polyurethane potting, thermoplastic bead separators, and a non-metallic\n      ABS frame\u003c\/strong\u003e to provide high-efficiency particulate filtration\n      for commercial, healthcare, pharmaceutical, industrial, VAV, air\n      handler, and built-up filter bank applications. Available in\n      MERV 11 through MERV 15 configurations with fully incinerable\n      construction for compatible disposal requirements.\n    \u003c\/p\u003e\n\n  \u003c\/section\u003e\n\n\u003c\/div\u003e\n\n\n\u003cstyle\u003e\n\n  .accurafil-product-description {\n    max-width: 1200px;\n    margin: 0 auto;\n    color: #2d3748;\n    line-height: 1.7;\n    font-size: 16px;\n  }\n\n\n  .accurafil-product-description h2 {\n    color: #007b8c;\n    font-size: 30px;\n    line-height: 1.25;\n    margin: 0 0 20px;\n  }\n\n\n  .accurafil-product-description h3 {\n    color: #0f4c5c;\n    font-size: 20px;\n    line-height: 1.35;\n    margin: 0 0 10px;\n  }\n\n\n  .product-intro {\n    background: #f0fdfa;\n    border-left: 5px solid #00ced3;\n    padding: 30px;\n    margin-bottom: 35px;\n    border-radius: 10px;\n  }\n\n\n  .product-eyebrow {\n    color: #007b8c;\n    font-size: 13px;\n    font-weight: 700;\n    letter-spacing: .08em;\n    text-transform: uppercase;\n    margin: 0 0 10px;\n  }\n\n\n  .product-intro p {\n    margin: 0 0 15px;\n  }\n\n\n  .product-intro p:last-child {\n    margin-bottom: 0;\n  }\n\n\n  .product-section {\n    background: #ffffff;\n    padding: 30px;\n    margin-bottom: 30px;\n    border-radius: 14px;\n    box-shadow: 0 8px 24px rgba(0, 0, 0, .06);\n  }\n\n\n  .product-section p {\n    margin: 0 0 15px;\n  }\n\n\n  .product-section p:last-child {\n    margin-bottom: 0;\n  }\n\n\n  .benefits-grid {\n    display: grid;\n    grid-template-columns: repeat(2, minmax(0, 1fr));\n    gap: 20px;\n  }\n\n\n  .benefit-card,\n  .merv-selection-card {\n    background: #f8fafc;\n    border: 1px solid #edf2f7;\n    border-radius: 10px;\n    padding: 22px;\n  }\n\n\n  .benefit-card p,\n  .merv-selection-card p {\n    margin: 0;\n    color: #4a5568;\n  }\n\n\n  .merv-selection-grid {\n    display: grid;\n    grid-template-columns: repeat(4, minmax(0, 1fr));\n    gap: 20px;\n    margin-top: 22px;\n  }\n\n\n  .merv-selection-card h3 {\n    color: #007b8c;\n  }\n\n\n  .carbon-callout {\n    display: flex;\n    align-items: flex-start;\n    gap: 20px;\n    background: linear-gradient(135deg, #1e293b 0%, #0f172a 100%);\n    border-radius: 10px;\n    padding: 24px;\n    margin-top: 24px;\n    color: #e2e8f0;\n  }\n\n\n  .carbon-callout-icon {\n    flex-shrink: 0;\n    width: 54px;\n    height: 54px;\n    background: #97e6e6;\n    border-radius: 10px;\n    display: flex;\n    align-items: center;\n    justify-content: center;\n    font-size: 26px;\n  }\n\n\n  .carbon-callout-body strong {\n    display: block;\n    font-size: 16px;\n    font-weight: 700;\n    color: #97e6e6;\n    margin-bottom: 6px;\n    text-transform: uppercase;\n    letter-spacing: .09em;\n  }\n\n\n  .carbon-callout-body p {\n    font-size: 15px;\n    color: #94a3b8;\n    line-height: 1.6;\n    margin: 0;\n  }\n\n\n  .gas-grid {\n    display: flex;\n    flex-wrap: wrap;\n    gap: 10px;\n    margin-top: 20px;\n  }\n\n\n  .gas-tag {\n    display: inline-flex;\n    align-items: center;\n    gap: 7px;\n    padding: 8px 16px;\n    border-radius: 100px;\n    font-size: 14px;\n    font-weight: 700;\n    background: #1e293b;\n    color: #e2e8f0;\n    border: 1px solid #334155;\n    letter-spacing: .04em;\n  }\n\n\n  .gas-tag-dot {\n    width: 8px;\n    height: 8px;\n    border-radius: 50%;\n    background: #97e6e6;\n    flex-shrink: 0;\n  }\n\n\n  .application-list {\n    margin: 15px 0 0;\n    padding-left: 22px;\n  }\n\n\n  .application-list li {\n    margin-bottom: 8px;\n  }\n\n\n  .howto-steps {\n    list-style: none;\n    display: flex;\n    flex-direction: column;\n    margin: 0;\n    padding: 0;\n  }\n\n\n  .howto-step {\n    display: flex;\n    gap: 18px;\n    align-items: flex-start;\n    padding: 20px 0;\n    border-bottom: 1px solid #edf2f7;\n  }\n\n\n  .howto-step:last-child {\n    border-bottom: none;\n  }\n\n\n  .step-number {\n    flex-shrink: 0;\n    width: 54px;\n    height: 54px;\n    background: #007b8c;\n    color: #ffffff;\n    border-radius: 50%;\n    display: flex;\n    align-items: center;\n    justify-content: center;\n    font-weight: 700;\n    font-size: 18px;\n  }\n\n\n  .step-content {\n    flex: 1;\n  }\n\n\n  .step-content h3 {\n    margin-bottom: 6px;\n  }\n\n\n  .step-content p {\n    color: #4a5568;\n    margin: 0;\n  }\n\n\n  .specifications-table-wrapper {\n    overflow-x: auto;\n  }\n\n\n  .specifications-table {\n    width: 100%;\n    border-collapse: collapse;\n  }\n\n\n  .specifications-table th,\n  .specifications-table td {\n    padding: 14px 16px;\n    border-bottom: 1px solid #edf2f7;\n    text-align: left;\n    vertical-align: top;\n  }\n\n\n  .specifications-table th {\n    width: 35%;\n    background: #f8fafc;\n    color: #4a5568;\n    font-weight: 700;\n  }\n\n\n  .grade-grid {\n    display: grid;\n    grid-template-columns: repeat(4, minmax(0, 1fr));\n    gap: 0;\n    border-radius: 10px;\n    overflow: hidden;\n    border: 1px solid rgba(30,126,79,0.2);\n    margin-top: 10px;\n  }\n\n\n  .grade-tier {\n    padding: 22px 12px;\n    text-align: center;\n    border-right: 1px solid rgba(30,126,79,0.15);\n  }\n\n\n  .grade-tier:last-child {\n    border-right: none;\n  }\n\n\n  .grade-tier-m6 {\n    background: #eafaf1;\n  }\n\n\n  .grade-tier-f7 {\n    background: #d5f5e3;\n  }\n\n\n  .grade-tier-f8 {\n    background: #a9dfbf;\n  }\n\n\n  .grade-tier-f9 {\n    background: #7dcea0;\n  }\n\n\n  .grade-en {\n    display: block;\n    font-size: 13px;\n    font-weight: 700;\n    text-transform: uppercase;\n    letter-spacing: .1em;\n    color: #1a4731;\n    margin-bottom: 4px;\n  }\n\n\n  .grade-merv {\n    display: block;\n    font-size: 30px;\n    font-weight: 700;\n    color: #1a4731;\n    line-height: 1.1;\n    margin-bottom: 6px;\n  }\n\n\n  .grade-label {\n    display: block;\n    font-size: 13px;\n    color: #1a4731;\n    opacity: .75;\n  }\n\n\n  .procurement-section {\n    background: #f8fafc;\n  }\n\n\n  .faq-item {\n    border-bottom: 1px solid #edf2f7;\n    padding: 18px 0;\n  }\n\n\n  .faq-item:last-child {\n    border-bottom: 0;\n  }\n\n\n  .faq-item summary {\n    cursor: pointer;\n    color: #0f4c5c;\n    font-size: 18px;\n    font-weight: 700;\n    padding-right: 20px;\n  }\n\n\n  .faq-answer {\n    padding: 12px 0 0;\n    color: #4a5568;\n  }\n\n\n  .faq-answer p {\n    margin: 0;\n  }\n\n\n  .product-final {\n    background: #0f4c5c;\n    color: #ffffff;\n    padding: 35px;\n    border-radius: 14px;\n    margin-top: 35px;\n  }\n\n\n  .product-final h2 {\n    color: #ffffff;\n  }\n\n\n  .product-final p {\n    margin: 0;\n  }\n\n\n  @media (max-width: 1000px) {\n\n    .merv-selection-grid {\n      grid-template-columns: repeat(2, minmax(0, 1fr));\n    }\n\n    .grade-grid {\n      grid-template-columns: repeat(2, minmax(0, 1fr));\n    }\n\n    .grade-tier:nth-child(2) {\n      border-right: none;\n    }\n\n    .grade-tier:nth-child(-n+2) {\n      border-bottom: 1px solid rgba(30,126,79,0.15);\n    }\n\n  }\n\n\n  @media (max-width: 768px) {\n\n    .accurafil-product-description {\n      font-size: 15px;\n    }\n\n    .accurafil-product-description h2 {\n      font-size: 25px;\n    }\n\n    .benefits-grid,\n    .merv-selection-grid {\n      grid-template-columns: 1fr;\n    }\n\n    .product-intro,\n    .product-section,\n    .product-final {\n      padding: 22px;\n    }\n\n    .specifications-table th,\n    .specifications-table td {\n      padding: 11px;\n    }\n\n    .carbon-callout {\n      flex-direction: column;\n    }\n\n    .grade-grid {\n      grid-template-columns: 1fr;\n    }\n\n    .grade-tier {\n      border-right: none;\n      border-bottom: 1px solid rgba(30,126,79,0.15);\n    }\n\n    .grade-tier:last-child {\n      border-bottom: none;\n    }\n\n  }\n\n\u003c\/style\u003e","brand":"AccuraFil","offers":[{"title":"24 x 12 x 12 \/ MERV 11 \/ 4V","offer_id":48955350188340,"sku":"11-18-1210131-195-0","price":148.77,"currency_code":"USD","in_stock":true},{"title":"24 x 12 x 12 \/ MERV 14 \/ 2V","offer_id":48955350221108,"sku":"11-18-1410050-195-00","price":129.58,"currency_code":"USD","in_stock":true},{"title":"24 x 12 x 12 \/ MERV 14 \/ 4V","offer_id":48955350253876,"sku":"11-18-1410000-195-0","price":152.57,"currency_code":"USD","in_stock":false},{"title":"24 x 12 x 12 \/ MERV 15 \/ 4V","offer_id":48955350286644,"sku":"11-18-1510031-195-0","price":180.5,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0716\/7767\/3780\/files\/12x24-4V_glass_V_Bank-PAck_of_2.jpg?v=1786477068"},{"product_id":"v-bank-synthetic-air-filter-12x24x12-merv-15","title":"V-Bank Synthetic Air Filter – 12x24x12 – MERV 15 – 4V – Pack of 2","description":"\u003cdiv class=\"accurafil-product-description\"\u003e\n\n  \u003c!-- =========================================================\n       PRODUCT INTRODUCTION\n       ========================================================= --\u003e\n\n  \u003csection class=\"product-intro\" aria-labelledby=\"product-description-heading\"\u003e\n\n    \u003cp class=\"product-eyebrow\"\u003e\n      High-Efficiency Synthetic HVAC Filtration\n    \u003c\/p\u003e\n\n    \u003ch2 id=\"product-description-heading\"\u003e\n      V-Bank Synthetic Air Filter\n    \u003c\/h2\u003e\n\n    \u003cp\u003e\n      AccuraFil V-Bank Synthetic Air Filters combine\n      \u003cstrong\u003ehigh-efficiency synthetic media, mini-pleat construction,\n      and V-bank geometry\u003c\/strong\u003e in a rigid box-style HVAC filter designed\n      for high airflow and low resistance. The extended-surface design\n      provides a large effective filtration area within a compact filter\n      footprint.\n    \u003c\/p\u003e\n\n    \u003cp\u003e\n      Available in \u003cstrong\u003eMERV 11, MERV 13, MERV 14, and MERV 15\u003c\/strong\u003e\n      configurations according to ASHRAE 52.2, corresponding to\n      \u003cstrong\u003eM6, F7, F8, and F9\u003c\/strong\u003e classifications under EN 779.\n      The filter uses high-efficiency synthetic media with thermoplastic\n      bead separators and an ABS plastic frame with a 20 mm header.\n      Its rigid construction is designed for variable and turbulent\n      airflow applications, including VAV systems, air handlers, built-up\n      filter banks, healthcare facilities, pharmaceutical environments,\n      data centers, and commercial HVAC systems.\n    \u003c\/p\u003e\n\n  \u003c\/section\u003e\n\n\n  \u003c!-- =========================================================\n       KEY BENEFITS\n       ========================================================= --\u003e\n\n  \u003csection class=\"product-section\" aria-labelledby=\"key-benefits-heading\"\u003e\n\n    \u003ch2 id=\"key-benefits-heading\"\u003e\n      Key Benefits\n    \u003c\/h2\u003e\n\n    \u003cdiv class=\"benefits-grid\"\u003e\n\n      \u003carticle class=\"benefit-card\"\u003e\n\n        \u003ch3\u003e\n          High-Efficiency Synthetic Media\n        \u003c\/h3\u003e\n\n        \u003cp\u003e\n          Synthetic filtration media provides efficient particulate\n          filtration across MERV 11 through MERV 15 configurations while\n          supporting resistance to moisture and demanding airflow conditions.\n        \u003c\/p\u003e\n\n      \u003c\/article\u003e\n\n\n      \u003carticle class=\"benefit-card\"\u003e\n\n        \u003ch3\u003e\n          Mini-Pleat V-Bank Design\n        \u003c\/h3\u003e\n\n        \u003cp\u003e\n          Extended-surface mini-pleat geometry maximizes effective media\n          area within the available filter footprint to support high airflow\n          with reduced resistance.\n        \u003c\/p\u003e\n\n      \u003c\/article\u003e\n\n\n      \u003carticle class=\"benefit-card\"\u003e\n\n        \u003ch3\u003e\n          Turbulence-Resistant Construction\n        \u003c\/h3\u003e\n\n        \u003cp\u003e\n          Rigid box construction and thermoplastic bead separators help\n          maintain pleat geometry and filtration performance under variable\n          and turbulent airflow conditions.\n        \u003c\/p\u003e\n\n      \u003c\/article\u003e\n\n\n      \u003carticle class=\"benefit-card\"\u003e\n\n        \u003ch3\u003e\n          Fully Incinerable Construction\n        \u003c\/h3\u003e\n\n        \u003cp\u003e\n          The non-metallic filter construction is fully incinerable,\n          allowing end-of-life disposal without separating metallic frame\n          components from the filter media.\n        \u003c\/p\u003e\n\n      \u003c\/article\u003e\n\n    \u003c\/div\u003e\n\n  \u003c\/section\u003e\n\n\n  \u003c!-- =========================================================\n       TECHNICAL SPECIFICATIONS\n       ========================================================= --\u003e\n\n  \u003csection class=\"product-section\" aria-labelledby=\"specifications-heading\"\u003e\n\n    \u003ch2 id=\"specifications-heading\"\u003e\n      Technical Specifications\n    \u003c\/h2\u003e\n\n    \u003cdiv class=\"specifications-table-wrapper\"\u003e\n\n      \u003ctable class=\"specifications-table\"\u003e\n\n        \u003ctbody\u003e\n\n          \u003ctr\u003e\n            \u003cth scope=\"row\"\u003e\n              Filter Type\n            \u003c\/th\u003e\n\n            \u003ctd\u003e\n              V-Bank Synthetic Air Filter — Rigid Box\n            \u003c\/td\u003e\n          \u003c\/tr\u003e\n\n\n          \u003ctr\u003e\n            \u003cth scope=\"row\"\u003e\n              Filter Grades\n            \u003c\/th\u003e\n\n            \u003ctd\u003e\n              MERV 15\n            \u003c\/td\u003e\n          \u003c\/tr\u003e\n\n\n          \u003ctr\u003e\n            \u003cth scope=\"row\"\u003e\n              Filtration Standard\n            \u003c\/th\u003e\n\n            \u003ctd\u003e\n              ASHRAE 52.2\n            \u003c\/td\u003e\n          \u003c\/tr\u003e\n\n\n          \u003ctr\u003e\n            \u003cth scope=\"row\"\u003e\n              EN 779 Grades\n            \u003c\/th\u003e\n\n            \u003ctd\u003e\n              F9\n            \u003c\/td\u003e\n          \u003c\/tr\u003e\n\n\n          \u003ctr\u003e\n            \u003cth scope=\"row\"\u003e\n              Filter Media\n            \u003c\/th\u003e\n\n            \u003ctd\u003e\n              High-Efficiency Synthetic Media\n            \u003c\/td\u003e\n          \u003c\/tr\u003e\n\n\n          \u003ctr\u003e\n            \u003cth scope=\"row\"\u003e\n              Media Separator\n            \u003c\/th\u003e\n\n            \u003ctd\u003e\n              Thermoplastic Bead Separators (Hot Melt Beads)\n            \u003c\/td\u003e\n          \u003c\/tr\u003e\n\n\n          \u003ctr\u003e\n            \u003cth scope=\"row\"\u003e\n              Frame Material\n            \u003c\/th\u003e\n\n            \u003ctd\u003e\n              ABS Plastic\n            \u003c\/td\u003e\n          \u003c\/tr\u003e\n\n\n          \u003ctr\u003e\n            \u003cth scope=\"row\"\u003e\n              Header Construction\n            \u003c\/th\u003e\n\n            \u003ctd\u003e\n              20 mm Header\n            \u003c\/td\u003e\n          \u003c\/tr\u003e\n\n\n          \u003ctr\u003e\n            \u003cth scope=\"row\"\u003e\n              Maximum Operating Temperature\n            \u003c\/th\u003e\n\n            \u003ctd\u003e\n              176°F (80°C)\n            \u003c\/td\u003e\n          \u003c\/tr\u003e\n\n\n          \u003ctr\u003e\n            \u003cth scope=\"row\"\u003e\n              Final Pressure Drop\n            \u003c\/th\u003e\n\n            \u003ctd\u003e\n              1.50\" w.g.\n            \u003c\/td\u003e\n          \u003c\/tr\u003e\n\n\n          \u003ctr\u003e\n            \u003cth scope=\"row\"\u003e\n              Maximum Recommended Pressure Drop\n            \u003c\/th\u003e\n\n            \u003ctd\u003e\n              2.00\" w.g.\n            \u003c\/td\u003e\n          \u003c\/tr\u003e\n\n\n          \u003ctr\u003e\n            \u003cth scope=\"row\"\u003e\n              Maximum Operating Velocity\n            \u003c\/th\u003e\n\n            \u003ctd\u003e\n              625 fpm \/ 3.175 m\/s\n            \u003c\/td\u003e\n          \u003c\/tr\u003e\n\n\n          \u003ctr\u003e\n            \u003cth scope=\"row\"\u003e\n              Disposal\n            \u003c\/th\u003e\n\n            \u003ctd\u003e\n              Fully Incinerable, Non-Metallic Construction\n            \u003c\/td\u003e\n          \u003c\/tr\u003e\n\u003ctr\u003e\n            \u003cth scope=\"row\"\u003e\n              Fire Classification\n            \u003c\/th\u003e\n\n            \u003ctd\u003e\n              UL900 Classified\n            \u003c\/td\u003e\n        \u003c\/tr\u003e\n\u003c\/tbody\u003e\n\n      \u003c\/table\u003e\n\n    \u003c\/div\u003e\n\n  \u003c\/section\u003e\n\n\n  \u003c!-- =========================================================\n       SYNTHETIC MEDIA PERFORMANCE\n       ========================================================= --\u003e\n\n  \u003csection class=\"product-section\" aria-labelledby=\"synthetic-performance-heading\"\u003e\n\n    \u003ch2 id=\"synthetic-performance-heading\"\u003e\n      High-Efficiency Synthetic Media Performance\n    \u003c\/h2\u003e\n\n    \u003cp\u003e\n      The V-Bank Synthetic Filter uses\n      \u003cstrong\u003ehigh-efficiency synthetic filtration media\u003c\/strong\u003e arranged\n      in a mini-pleat configuration. The extended media surface area allows\n      the filter to provide efficient particulate filtration while\n      maintaining the compact rigid-box format required by many HVAC\n      installations.\n    \u003c\/p\u003e\n\n    \u003cp\u003e\n      The synthetic media construction is designed for demanding operating\n      conditions where moisture exposure, variable airflow, and turbulence\n      can affect conventional filter designs. The filter is available from\n      MERV 11 through MERV 15 to accommodate different particulate\n      filtration requirements.\n    \u003c\/p\u003e\n\n    \u003cdiv class=\"synthetic-callout\"\u003e\n\n      \u003cdiv class=\"synthetic-callout-icon\" aria-hidden=\"true\"\u003e\n        🧵\n      \u003c\/div\u003e\n\n      \u003cdiv class=\"synthetic-callout-body\"\u003e\n\n        \u003cstrong\u003e\n          Durable Synthetic Filtration\n        \u003c\/strong\u003e\n\n        \u003cp\u003e\n          High-efficiency synthetic media provides a combination of\n          particulate filtration, moisture resistance, and durability for\n          demanding HVAC applications.\n        \u003c\/p\u003e\n\n      \u003c\/div\u003e\n\n    \u003c\/div\u003e\n\n  \u003c\/section\u003e\n\n\n  \u003c!-- =========================================================\n       FILTER GRADE SELECTION\n       ========================================================= --\u003e\n\n  \u003csection class=\"product-section\" aria-labelledby=\"grade-selection-heading\"\u003e\n\n    \u003ch2 id=\"grade-selection-heading\"\u003e\n      MERV \u0026amp; EN 779 Filter Grade Selection\n    \u003c\/h2\u003e\n\n    \u003cp\u003e\n      Select the appropriate filter grade according to the facility's\n      particulate filtration requirements, HVAC design, airflow conditions,\n      and allowable pressure drop.\n    \u003c\/p\u003e\n\n    \u003cdiv class=\"grade-selection-grid\"\u003e\n\n      \u003carticle class=\"grade-selection-card\"\u003e\n\n        \u003cspan class=\"grade-standard\"\u003e\n          EN 779 M6\n        \u003c\/span\u003e\n\n        \u003ch3\u003e\n          MERV 11\n        \u003c\/h3\u003e\n\n        \u003cp\u003e\n          Suitable for general commercial ventilation and applications\n          requiring moderate particulate filtration performance.\n        \u003c\/p\u003e\n\n      \u003c\/article\u003e\n\n\n      \u003carticle class=\"grade-selection-card\"\u003e\n\n        \u003cspan class=\"grade-standard\"\u003e\n          EN 779 F7\n        \u003c\/span\u003e\n\n        \u003ch3\u003e\n          MERV 13\n        \u003c\/h3\u003e\n\n        \u003cp\u003e\n          Higher-efficiency particulate filtration for offices, hotels,\n          light healthcare, and commercial HVAC applications.\n        \u003c\/p\u003e\n\n      \u003c\/article\u003e\n\n\n      \u003carticle class=\"grade-selection-card\"\u003e\n\n        \u003cspan class=\"grade-standard\"\u003e\n          EN 779 F8\n        \u003c\/span\u003e\n\n        \u003ch3\u003e\n          MERV 14\n        \u003c\/h3\u003e\n\n        \u003cp\u003e\n          Higher filtration efficiency for hospitals, laboratories,\n          LEED buildings, and other demanding commercial applications.\n        \u003c\/p\u003e\n\n      \u003c\/article\u003e\n\n\n      \u003carticle class=\"grade-selection-card\"\u003e\n\n        \u003cspan class=\"grade-standard\"\u003e\n          EN 779 F9\n        \u003c\/span\u003e\n\n        \u003ch3\u003e\n          MERV 15\n        \u003c\/h3\u003e\n\n        \u003cp\u003e\n          High-efficiency particulate filtration for pharmaceutical,\n          ISO cleanroom, healthcare, and critical HVAC environments.\n        \u003c\/p\u003e\n\n      \u003c\/article\u003e\n\n    \u003c\/div\u003e\n\n  \u003c\/section\u003e\n\n\n  \u003c!-- =========================================================\n       V-BANK DESIGN\n       ========================================================= --\u003e\n\n  \u003csection class=\"product-section\" aria-labelledby=\"vbank-design-heading\"\u003e\n\n    \u003ch2 id=\"vbank-design-heading\"\u003e\n      V-Bank Mini-Pleat Design for High Airflow\n    \u003c\/h2\u003e\n\n    \u003cp\u003e\n      The V-bank configuration divides the filter media into angled\n      sections, increasing the effective filtration surface area available\n      within the filter footprint. Combined with the mini-pleat design,\n      this configuration supports high airflow while minimizing resistance.\n    \u003c\/p\u003e\n\n    \u003cp\u003e\n      The extended-surface construction is designed to provide greater\n      media utilization than conventional flat panel arrangements while\n      maintaining a compact rigid box configuration suitable for air\n      handlers, filter banks, and VAV systems.\n    \u003c\/p\u003e\n\n  \u003c\/section\u003e\n\n\n  \u003c!-- =========================================================\n       AIRFLOW \u0026 TURBULENCE PERFORMANCE\n       ========================================================= --\u003e\n\n  \u003csection class=\"product-section\" aria-labelledby=\"airflow-performance-heading\"\u003e\n\n    \u003ch2 id=\"airflow-performance-heading\"\u003e\n      Performance Under Variable \u0026amp; Turbulent Airflow\n    \u003c\/h2\u003e\n\n    \u003cp\u003e\n      The rigid box construction and thermoplastic bead separators are\n      designed to maintain consistent pleat geometry under variable\n      airflow and turbulent operating conditions. This makes the V-Bank\n      Synthetic Filter particularly suitable for HVAC systems where\n      airflow demand changes during operation.\n    \u003c\/p\u003e\n\n    \u003cdiv class=\"performance-grid\"\u003e\n\n      \u003carticle class=\"performance-card\"\u003e\n\n        \u003ch3\u003e\n          Maximum Operating Velocity\n        \u003c\/h3\u003e\n\n        \u003cp\u003e\n          The specified maximum operating velocity is\n          \u003cstrong\u003e625 fpm (3.175 m\/s)\u003c\/strong\u003e.\n        \u003c\/p\u003e\n\n      \u003c\/article\u003e\n\n\n      \u003carticle class=\"performance-card\"\u003e\n\n        \u003ch3\u003e\n          Final Pressure Drop\n        \u003c\/h3\u003e\n\n        \u003cp\u003e\n          The specified final pressure drop is\n          \u003cstrong\u003e1.50\" w.g.\u003c\/strong\u003e.\n        \u003c\/p\u003e\n\n      \u003c\/article\u003e\n\n\n      \u003carticle class=\"performance-card\"\u003e\n\n        \u003ch3\u003e\n          Maximum Recommended Pressure Drop\n        \u003c\/h3\u003e\n\n        \u003cp\u003e\n          The maximum recommended pressure drop is\n          \u003cstrong\u003e2.00\" w.g.\u003c\/strong\u003e.\n        \u003c\/p\u003e\n\n      \u003c\/article\u003e\n\n\n      \u003carticle class=\"performance-card\"\u003e\n\n        \u003ch3\u003e\n          Turbulence-Resistant Design\n        \u003c\/h3\u003e\n\n        \u003cp\u003e\n          Rigid construction and thermoplastic bead separators help maintain\n          pleat spacing during variable airflow conditions.\n        \u003c\/p\u003e\n\n      \u003c\/article\u003e\n\n    \u003c\/div\u003e\n\n  \u003c\/section\u003e\n\n\n  \u003c!-- =========================================================\n       FRAME \u0026 HEADER\n       ========================================================= --\u003e\n\n  \u003csection class=\"product-section\" aria-labelledby=\"frame-heading\"\u003e\n\n    \u003ch2 id=\"frame-heading\"\u003e\n      ABS Frame \u0026amp; 20 mm Header Construction\n    \u003c\/h2\u003e\n\n    \u003cp\u003e\n      The V-Bank Synthetic Filter uses a\n      \u003cstrong\u003enon-metallic ABS plastic frame\u003c\/strong\u003e designed to provide\n      a lightweight and durable enclosure for the synthetic media pack.\n    \u003c\/p\u003e\n\n    \u003cp\u003e\n      The \u003cstrong\u003e20 mm header\u003c\/strong\u003e provides the mounting interface\n      for compatible HVAC filter racks and built-up filter bank systems.\n    \u003c\/p\u003e\n\n    \u003cp\u003e\n      Always verify the existing housing dimensions, header configuration,\n      sealing arrangement, and installation orientation before ordering\n      a replacement filter.\n    \u003c\/p\u003e\n\n  \u003c\/section\u003e\n\n\n  \u003c!-- =========================================================\n       DISPOSAL\n       ========================================================= --\u003e\n\n  \u003csection class=\"product-section\" aria-labelledby=\"disposal-heading\"\u003e\n\n    \u003ch2 id=\"disposal-heading\"\u003e\n      Fully Incinerable Non-Metallic Construction\n    \u003c\/h2\u003e\n\n    \u003cp\u003e\n      The V-Bank Synthetic Filter uses a\n      \u003cstrong\u003enon-metallic, fully incinerable construction\u003c\/strong\u003e.\n      The filter can be disposed of by incineration without separating\n      metallic frame components from the filter media.\n    \u003c\/p\u003e\n\n    \u003cp\u003e\n      This construction can simplify end-of-life handling for facilities\n      where incinerable filter disposal is preferred or required,\n      including compatible pharmaceutical, healthcare, food processing,\n      and other controlled environments.\n    \u003c\/p\u003e\n\n  \u003c\/section\u003e\n\n\n  \u003c!-- =========================================================\n       INDUSTRY APPLICATIONS\n       ========================================================= --\u003e\n\n  \u003csection class=\"product-section\" aria-labelledby=\"applications-heading\"\u003e\n\n    \u003ch2 id=\"applications-heading\"\u003e\n      Commercial \u0026amp; Industrial HVAC Applications\n    \u003c\/h2\u003e\n\n    \u003cp\u003e\n      AccuraFil V-Bank Synthetic Filters are designed for high-efficiency\n      particulate filtration in a wide range of commercial and industrial\n      HVAC applications, including:\n    \u003c\/p\u003e\n\n    \u003cul class=\"application-list\"\u003e\n\n      \u003cli\u003e\n        Variable Air Volume (VAV) systems\n      \u003c\/li\u003e\n\n      \u003cli\u003e\n        Commercial office buildings and hotels\n      \u003c\/li\u003e\n\n      \u003cli\u003e\n        Hospitals and healthcare facilities\n      \u003c\/li\u003e\n\n      \u003cli\u003e\n        Pharmaceutical and biotechnology facilities\n      \u003c\/li\u003e\n\n      \u003cli\u003e\n        Laboratories and controlled environments\n      \u003c\/li\u003e\n\n      \u003cli\u003e\n        Data centers and mission-critical facilities\n      \u003c\/li\u003e\n\n      \u003cli\u003e\n        Built-up HVAC filter banks\n      \u003c\/li\u003e\n\n      \u003cli\u003e\n        Air handling units and commercial HVAC systems\n      \u003c\/li\u003e\n\n      \u003cli\u003e\n        High-humidity HVAC environments\n      \u003c\/li\u003e\n\n      \u003cli\u003e\n        Food processing facilities requiring compatible incinerable\n        filter construction\n      \u003c\/li\u003e\n\n    \u003c\/ul\u003e\n\n  \u003c\/section\u003e\n\n\n  \u003c!-- =========================================================\n       HIGH-DEMAND ENVIRONMENTS\n       ========================================================= --\u003e\n\n  \u003csection class=\"product-section\" aria-labelledby=\"high-demand-heading\"\u003e\n\n    \u003ch2 id=\"high-demand-heading\"\u003e\n      Reliable Performance in High-Demand Environments\n    \u003c\/h2\u003e\n\n    \u003cp\u003e\n      The combination of high-efficiency synthetic media, mini-pleat\n      V-bank geometry, and rigid box construction makes the filter suitable\n      for HVAC systems exposed to high airflow, variable operating\n      conditions, and demanding maintenance requirements.\n    \u003c\/p\u003e\n\n\n    \u003ch3\u003e\n      VAV \u0026amp; Turbulent Airflow Systems\n    \u003c\/h3\u003e\n\n    \u003cp\u003e\n      The rigid filter construction and thermoplastic bead separators are\n      designed to help maintain media geometry and filtration performance\n      under variable airflow conditions.\n    \u003c\/p\u003e\n\n\n    \u003ch3\u003e\n      Hospitals \u0026amp; Healthcare\n    \u003c\/h3\u003e\n\n    \u003cp\u003e\n      High-efficiency MERV configurations provide particulate filtration\n      for compatible healthcare HVAC systems, while the non-metallic\n      construction supports simplified incinerable disposal.\n    \u003c\/p\u003e\n\n\n    \u003ch3\u003e\n      Pharmaceutical Manufacturing\n    \u003c\/h3\u003e\n\n    \u003cp\u003e\n      MERV 14 and MERV 15 configurations provide high-efficiency\n      particulate filtration for compatible pharmaceutical and controlled\n      environments where airflow stability and end-of-life handling are\n      important considerations.\n    \u003c\/p\u003e\n\n\n    \u003ch3\u003e\n      Data Centers\n    \u003c\/h3\u003e\n\n    \u003cp\u003e\n      High-efficiency synthetic filtration helps provide particulate control\n      for sensitive electronic environments, while the rigid V-bank design\n      supports demanding continuous HVAC operation.\n    \u003c\/p\u003e\n\n\n    \u003ch3\u003e\n      High-Humidity Environments\n    \u003c\/h3\u003e\n\n    \u003cp\u003e\n      Synthetic media is designed to resist moisture-related degradation,\n      supporting applications where elevated humidity is an important\n      operating consideration.\n    \u003c\/p\u003e\n\n\n    \u003ch3\u003e\n      Built-Up Filter Banks\n    \u003c\/h3\u003e\n\n    \u003cp\u003e\n      The rigid box configuration with ABS frame and 20 mm header is\n      designed for installation in compatible cell housings and\n      multi-filter HVAC bank configurations.\n    \u003c\/p\u003e\n\n  \u003c\/section\u003e\n\n\n  \u003c!-- =========================================================\n       PERFORMANCE BENEFITS\n       ========================================================= --\u003e\n\n  \u003csection class=\"product-section\" aria-labelledby=\"performance-heading\"\u003e\n\n    \u003ch2 id=\"performance-heading\"\u003e\n      High-Airflow Synthetic Filtration Performance\n    \u003c\/h2\u003e\n\n    \u003cdiv class=\"benefits-grid\"\u003e\n\n      \u003carticle class=\"benefit-card\"\u003e\n\n        \u003ch3\u003e\n          Large Effective Media Area\n        \u003c\/h3\u003e\n\n        \u003cp\u003e\n          Mini-pleat V-bank geometry increases the effective filtration\n          surface area within the available filter footprint.\n        \u003c\/p\u003e\n\n      \u003c\/article\u003e\n\n\n      \u003carticle class=\"benefit-card\"\u003e\n\n        \u003ch3\u003e\n          Lower Resistance\n        \u003c\/h3\u003e\n\n        \u003cp\u003e\n          The extended-surface design is engineered to support efficient\n          airflow with controlled pressure resistance.\n        \u003c\/p\u003e\n\n      \u003c\/article\u003e\n\n\n      \u003carticle class=\"benefit-card\"\u003e\n\n        \u003ch3\u003e\n          Durable Synthetic Media\n        \u003c\/h3\u003e\n\n        \u003cp\u003e\n          Synthetic media provides a resilient filtration structure for\n          variable airflow and elevated-humidity HVAC conditions.\n        \u003c\/p\u003e\n\n      \u003c\/article\u003e\n\n\n      \u003carticle class=\"benefit-card\"\u003e\n\n        \u003ch3\u003e\n          Reduced Filter Handling Complexity\n        \u003c\/h3\u003e\n\n        \u003cp\u003e\n          Fully incinerable non-metallic construction can simplify\n          end-of-life handling where incineration is an applicable\n          disposal method.\n        \u003c\/p\u003e\n\n      \u003c\/article\u003e\n\n    \u003c\/div\u003e\n\n  \u003c\/section\u003e\n\n\n  \u003c!-- =========================================================\n       SELECTION GUIDE\n       ========================================================= --\u003e\n\n  \u003csection class=\"product-section\" aria-labelledby=\"selection-guide-heading\"\u003e\n\n    \u003ch2 id=\"selection-guide-heading\"\u003e\n      How to Select the Right V-Bank Synthetic Filter\n    \u003c\/h2\u003e\n\n    \u003col class=\"howto-steps\"\u003e\n\n      \u003cli class=\"howto-step\"\u003e\n\n        \u003cspan class=\"step-number\" aria-hidden=\"true\"\u003e\n          1\n        \u003c\/span\u003e\n\n        \u003cdiv class=\"step-content\"\u003e\n\n          \u003ch3\u003e\n            Identify the Required MERV Rating\n          \u003c\/h3\u003e\n\n          \u003cp\u003e\n            Select MERV 11, MERV 13, MERV 14, or MERV 15 according to the\n            particulate filtration requirements of the facility and HVAC\n            application.\n          \u003c\/p\u003e\n\n        \u003c\/div\u003e\n\n      \u003c\/li\u003e\n\n\n      \u003cli class=\"howto-step\"\u003e\n\n        \u003cspan class=\"step-number\" aria-hidden=\"true\"\u003e\n          2\n        \u003c\/span\u003e\n\n        \u003cdiv class=\"step-content\"\u003e\n\n          \u003ch3\u003e\n            Verify Airflow \u0026amp; Pressure-Drop Requirements\n          \u003c\/h3\u003e\n\n          \u003cp\u003e\n            Confirm that system airflow remains within the specified\n            maximum operating velocity of \u003cstrong\u003e625 fpm\n            (3.175 m\/s)\u003c\/strong\u003e and that the HVAC system can accommodate\n            the specified pressure-drop conditions.\n          \u003c\/p\u003e\n\n        \u003c\/div\u003e\n\n      \u003c\/li\u003e\n\n\n      \u003cli class=\"howto-step\"\u003e\n\n        \u003cspan class=\"step-number\" aria-hidden=\"true\"\u003e\n          3\n        \u003c\/span\u003e\n\n        \u003cdiv class=\"step-content\"\u003e\n\n          \u003ch3\u003e\n            Confirm Housing Compatibility\n          \u003c\/h3\u003e\n\n          \u003cp\u003e\n            Verify that the existing housing accepts the required\n            \u003cstrong\u003eV-bank rigid box configuration with ABS frame and\n            20 mm header\u003c\/strong\u003e. Confirm actual filter dimensions,\n            mounting arrangement, and sealing requirements before ordering.\n          \u003c\/p\u003e\n\n        \u003c\/div\u003e\n\n      \u003c\/li\u003e\n\n\n      \u003cli class=\"howto-step\"\u003e\n\n        \u003cspan class=\"step-number\" aria-hidden=\"true\"\u003e\n          4\n        \u003c\/span\u003e\n\n        \u003cdiv class=\"step-content\"\u003e\n\n          \u003ch3\u003e\n            Verify Operating Conditions \u0026amp; Disposal Requirements\n          \u003c\/h3\u003e\n\n          \u003cp\u003e\n            Confirm operating temperature does not exceed\n            \u003cstrong\u003e176°F (80°C)\u003c\/strong\u003e. Where incinerable disposal is\n            applicable, confirm that the facility's disposal process accepts\n            the filter's fully incinerable non-metallic construction.\n          \u003c\/p\u003e\n\n        \u003c\/div\u003e\n\n      \u003c\/li\u003e\n\n    \u003c\/ol\u003e\n\n  \u003c\/section\u003e\n\n\n  \u003c!-- =========================================================\n       PRODUCT COMPARISON\n       ========================================================= --\u003e\n\n  \u003csection class=\"product-section\" aria-labelledby=\"comparison-heading\"\u003e\n\n    \u003ch2 id=\"comparison-heading\"\u003e\n      V-Bank Synthetic Filter vs. Bag Filters \u0026amp; Standard Box Filters\n    \u003c\/h2\u003e\n\n    \u003cp\u003e\n      Compared with conventional bag-style filters, the V-Bank Synthetic\n      Filter uses a rigid box configuration and mini-pleat V-bank geometry.\n      This provides a more structurally stable format for applications\n      exposed to variable or turbulent airflow while maximizing the\n      available media surface area within the filter footprint.\n    \u003c\/p\u003e\n\n    \u003cp\u003e\n      Compared with conventional standard box filters, the mini-pleat\n      V-bank configuration is designed to provide high effective media\n      area and efficient airflow in a compact rigid construction. Synthetic\n      media additionally provides moisture resistance and a fully\n      incinerable non-metallic construction for compatible applications.\n    \u003c\/p\u003e\n\n    \u003cp\u003e\n      The appropriate filter selection depends on required MERV efficiency,\n      airflow, pressure drop, housing configuration, operating environment,\n      and disposal requirements.\n    \u003c\/p\u003e\n\n  \u003c\/section\u003e\n\n\n  \u003c!-- =========================================================\n       PRODUCT SELECTION \u0026 PROCUREMENT\n       ========================================================= --\u003e\n\n  \u003csection class=\"product-section procurement-section\" aria-labelledby=\"procurement-heading\"\u003e\n\n    \u003ch2 id=\"procurement-heading\"\u003e\n      Product Selection \u0026amp; Procurement\n    \u003c\/h2\u003e\n\n    \u003cp\u003e\n      Before ordering a replacement V-Bank Synthetic Filter, verify the\n      \u003cstrong\u003eactual filter dimensions\u003c\/strong\u003e, MERV rating, V-bank\n      configuration, ABS frame and 20 mm header requirements, airflow,\n      pressure-drop limitations, and compatibility with the existing HVAC\n      housing or filter bank.\n    \u003c\/p\u003e\n\n    \u003cp\u003e\n      For variable-airflow systems, confirm that the application operates\n      within the specified maximum velocity and pressure-drop limits.\n      Verify that the filter construction is suitable for the operating\n      temperature and humidity conditions.\n    \u003c\/p\u003e\n\n    \u003cp\u003e\n      Where incinerable disposal is required, confirm that the facility's\n      disposal process accepts fully incinerable non-metallic filter\n      construction without requiring separation of components.\n    \u003c\/p\u003e\n\n    \u003cp\u003e\n      AccuraFil provides commercial and industrial HVAC filtration solutions\n      for facility managers, HVAC contractors, mechanical engineers,\n      healthcare organizations, pharmaceutical facilities, data center\n      operators, filter-bank designers, and procurement teams.\n    \u003c\/p\u003e\n\n  \u003c\/section\u003e\n\n\n  \u003c!-- =========================================================\n       FAQ\n       ========================================================= --\u003e\n\n  \u003csection class=\"product-section\" aria-labelledby=\"faq-heading\"\u003e\n\n    \u003ch2 id=\"faq-heading\"\u003e\n      Frequently Asked Questions\n    \u003c\/h2\u003e\n\n\n    \u003cdetails class=\"faq-item\"\u003e\n\n      \u003csummary\u003e\n        What is a V-Bank Synthetic Filter?\n      \u003c\/summary\u003e\n\n      \u003cdiv class=\"faq-answer\"\u003e\n\n        \u003cp\u003e\n          A V-Bank Synthetic Filter is a rigid box-style HVAC filter that\n          uses high-efficiency synthetic media arranged in a V-bank\n          mini-pleat configuration. The design provides an extended\n          filtration surface within a compact footprint and is intended\n          for efficient airflow and demanding HVAC applications.\n        \u003c\/p\u003e\n\n      \u003c\/div\u003e\n\n    \u003c\/details\u003e\n\n\n    \u003cdetails class=\"faq-item\"\u003e\n\n      \u003csummary\u003e\n        What MERV ratings are available?\n      \u003c\/summary\u003e\n\n      \u003cdiv class=\"faq-answer\"\u003e\n\n        \u003cp\u003e\n          The AccuraFil V-Bank Synthetic Filter is available in\n          \u003cstrong\u003eMERV 11, MERV 13, MERV 14, and MERV 15\u003c\/strong\u003e according\n          to the supplied product specifications. These correspond to\n          EN 779 classifications M6, F7, F8, and F9 respectively.\n        \u003c\/p\u003e\n\n      \u003c\/div\u003e\n\n    \u003c\/details\u003e\n\n\n    \u003cdetails class=\"faq-item\"\u003e\n\n      \u003csummary\u003e\n        What are the advantages of synthetic media?\n      \u003c\/summary\u003e\n\n      \u003cdiv class=\"faq-answer\"\u003e\n\n        \u003cp\u003e\n          High-efficiency synthetic media provides a resilient filtration\n          structure and is designed to resist moisture-related degradation.\n          This makes it suitable for compatible HVAC applications involving\n          variable airflow, turbulence, or elevated humidity.\n        \u003c\/p\u003e\n\n      \u003c\/div\u003e\n\n    \u003c\/details\u003e\n\n\n    \u003cdetails class=\"faq-item\"\u003e\n\n      \u003csummary\u003e\n        What are thermoplastic bead separators?\n      \u003c\/summary\u003e\n\n      \u003cdiv class=\"faq-answer\"\u003e\n\n        \u003cp\u003e\n          Thermoplastic bead separators, also known as hot melt beads,\n          maintain the spacing between the mini-pleats in the synthetic\n          media pack. Their non-metallic construction contributes to the\n          filter's fully incinerable design.\n        \u003c\/p\u003e\n\n      \u003c\/div\u003e\n\n    \u003c\/details\u003e\n\n\n    \u003cdetails class=\"faq-item\"\u003e\n\n      \u003csummary\u003e\n        How does the V-Bank Synthetic Filter perform under turbulent airflow?\n      \u003c\/summary\u003e\n\n      \u003cdiv class=\"faq-answer\"\u003e\n\n        \u003cp\u003e\n          The rigid box construction and thermoplastic bead separators are\n          designed to help maintain pleat geometry and filtration performance\n          under variable and turbulent airflow conditions. This makes the\n          filter suitable for VAV systems and other applications where\n          airflow conditions fluctuate during operation.\n        \u003c\/p\u003e\n\n      \u003c\/div\u003e\n\n    \u003c\/details\u003e\n\n\n    \u003cdetails class=\"faq-item\"\u003e\n\n      \u003csummary\u003e\n        What is the maximum operating velocity?\n      \u003c\/summary\u003e\n\n      \u003cdiv class=\"faq-answer\"\u003e\n\n        \u003cp\u003e\n          The specified maximum operating velocity is\n          \u003cstrong\u003e625 fpm (3.175 m\/s)\u003c\/strong\u003e. HVAC system airflow should\n          be verified against this limit before specifying the filter.\n        \u003c\/p\u003e\n\n      \u003c\/div\u003e\n\n    \u003c\/details\u003e\n\n\n    \u003cdetails class=\"faq-item\"\u003e\n\n      \u003csummary\u003e\n        What frame and header configuration does the filter use?\n      \u003c\/summary\u003e\n\n      \u003cdiv class=\"faq-answer\"\u003e\n\n        \u003cp\u003e\n          The specified configuration uses a\n          \u003cstrong\u003enon-metallic ABS plastic frame with a 20 mm header\u003c\/strong\u003e.\n          Verify that the existing HVAC filter housing or built-up filter\n          bank is compatible with this configuration before ordering.\n        \u003c\/p\u003e\n\n      \u003c\/div\u003e\n\n    \u003c\/details\u003e\n\n\n    \u003cdetails class=\"faq-item\"\u003e\n\n      \u003csummary\u003e\n        Is the V-Bank Synthetic Filter fully incinerable?\n      \u003c\/summary\u003e\n\n      \u003cdiv class=\"faq-answer\"\u003e\n\n        \u003cp\u003e\n          Yes. The supplied product specifications identify the filter as\n          having a \u003cstrong\u003efully incinerable, non-metallic construction\u003c\/strong\u003e.\n          Confirm that the facility's disposal process accepts this disposal\n          method before use.\n        \u003c\/p\u003e\n\n      \u003c\/div\u003e\n\n    \u003c\/details\u003e\n\n\n    \u003cdetails class=\"faq-item\"\u003e\n\n      \u003csummary\u003e\n        What is the maximum operating temperature?\n      \u003c\/summary\u003e\n\n      \u003cdiv class=\"faq-answer\"\u003e\n\n        \u003cp\u003e\n          The specified maximum operating temperature is\n          \u003cstrong\u003e176°F (80°C)\u003c\/strong\u003e.\n        \u003c\/p\u003e\n\n      \u003c\/div\u003e\n\n    \u003c\/details\u003e\n\n\n    \u003cdetails class=\"faq-item\"\u003e\n\n      \u003csummary\u003e\n        What is the recommended final pressure drop?\n      \u003c\/summary\u003e\n\n      \u003cdiv class=\"faq-answer\"\u003e\n\n        \u003cp\u003e\n          The specified final pressure drop is\n          \u003cstrong\u003e1.50\" w.g.\u003c\/strong\u003e, with a maximum recommended pressure\n          drop of \u003cstrong\u003e2.00\" w.g.\u003c\/strong\u003e. Confirm that the HVAC system\n          can support the required pressure-drop conditions before ordering.\n        \u003c\/p\u003e\n\n      \u003c\/div\u003e\n\n    \u003c\/details\u003e\n\n\n  \u003c\/section\u003e\n\n\n  \u003c!-- =========================================================\n       FINAL PRODUCT STATEMENT\n       ========================================================= --\u003e\n\n  \u003csection class=\"product-final\"\u003e\n\n    \u003ch2\u003e\n      AccuraFil V-Bank Synthetic Air Filters\n    \u003c\/h2\u003e\n\n    \u003cp\u003e\n      AccuraFil V-Bank Synthetic Air Filters combine\n      \u003cstrong\u003ehigh-efficiency synthetic media, mini-pleat V-bank geometry,\n      rigid box construction, and a non-metallic ABS frame\u003c\/strong\u003e for\n      high-airflow commercial and industrial HVAC applications. Available\n      in MERV 11, MERV 13, MERV 14, and MERV 15 configurations, the design\n      provides efficient particulate filtration, turbulence-resistant\n      construction, moisture resistance, and fully incinerable\n      non-metallic disposal for compatible applications.\n    \u003c\/p\u003e\n\n  \u003c\/section\u003e\n\n\u003c\/div\u003e\n\n\n\u003cstyle\u003e\n\n  .accurafil-product-description {\n    max-width: 1200px;\n    margin: 0 auto;\n    color: #2d3748;\n    line-height: 1.7;\n    font-size: 16px;\n  }\n\n\n  .accurafil-product-description h2 {\n    color: #007b8c;\n    font-size: 30px;\n    line-height: 1.25;\n    margin: 0 0 20px;\n  }\n\n\n  .accurafil-product-description h3 {\n    color: #0f4c5c;\n    font-size: 20px;\n    line-height: 1.35;\n    margin: 0 0 10px;\n  }\n\n\n  .product-intro {\n    background: #f0fdfa;\n    border-left: 5px solid #00ced3;\n    padding: 30px;\n    margin-bottom: 35px;\n    border-radius: 10px;\n  }\n\n\n  .product-eyebrow {\n    color: #007b8c;\n    font-size: 13px;\n    font-weight: 700;\n    letter-spacing: .08em;\n    text-transform: uppercase;\n    margin: 0 0 10px;\n  }\n\n\n  .product-intro p {\n    margin: 0 0 15px;\n  }\n\n\n  .product-intro p:last-child {\n    margin-bottom: 0;\n  }\n\n\n  .product-section {\n    background: #ffffff;\n    padding: 30px;\n    margin-bottom: 30px;\n    border-radius: 14px;\n    box-shadow: 0 8px 24px rgba(0, 0, 0, .06);\n  }\n\n\n  .product-section p {\n    margin: 0 0 15px;\n  }\n\n\n  .product-section p:last-child {\n    margin-bottom: 0;\n  }\n\n\n  .benefits-grid {\n    display: grid;\n    grid-template-columns: repeat(2, minmax(0, 1fr));\n    gap: 20px;\n  }\n\n\n  .benefit-card,\n  .grade-selection-card,\n  .performance-card {\n    background: #f8fafc;\n    border: 1px solid #edf2f7;\n    border-radius: 10px;\n    padding: 22px;\n  }\n\n\n  .benefit-card p,\n  .grade-selection-card p,\n  .performance-card p {\n    margin: 0;\n    color: #4a5568;\n  }\n\n\n  .grade-selection-grid {\n    display: grid;\n    grid-template-columns: repeat(4, minmax(0, 1fr));\n    gap: 20px;\n    margin-top: 22px;\n  }\n\n\n  .grade-selection-card {\n    text-align: center;\n  }\n\n\n  .grade-selection-card h3 {\n    color: #007b8c;\n    font-size: 28px;\n    margin-bottom: 10px;\n  }\n\n\n  .grade-standard {\n    display: block;\n    color: #4a5568;\n    font-size: 12px;\n    font-weight: 700;\n    letter-spacing: .08em;\n    text-transform: uppercase;\n    margin-bottom: 7px;\n  }\n\n\n  .synthetic-callout {\n    display: flex;\n    align-items: flex-start;\n    gap: 20px;\n    background: linear-gradient(135deg, #1e293b 0%, #0f172a 100%);\n    border-radius: 10px;\n    padding: 24px;\n    margin-top: 24px;\n    color: #e2e8f0;\n  }\n\n\n  .synthetic-callout-icon {\n    flex-shrink: 0;\n    width: 54px;\n    height: 54px;\n    background: #97e6e6;\n    border-radius: 10px;\n    display: flex;\n    align-items: center;\n    justify-content: center;\n    font-size: 26px;\n  }\n\n\n  .synthetic-callout-body strong {\n    display: block;\n    font-size: 16px;\n    font-weight: 700;\n    color: #97e6e6;\n    margin-bottom: 6px;\n    text-transform: uppercase;\n    letter-spacing: .09em;\n  }\n\n\n  .synthetic-callout-body p {\n    font-size: 15px;\n    color: #94a3b8;\n    line-height: 1.6;\n    margin: 0;\n  }\n\n\n  .performance-grid {\n    display: grid;\n    grid-template-columns: repeat(2, minmax(0, 1fr));\n    gap: 20px;\n    margin-top: 22px;\n  }\n\n\n  .application-list {\n    margin: 15px 0 0;\n    padding-left: 22px;\n  }\n\n\n  .application-list li {\n    margin-bottom: 8px;\n  }\n\n\n  .howto-steps {\n    list-style: none;\n    display: flex;\n    flex-direction: column;\n    margin: 0;\n    padding: 0;\n  }\n\n\n  .howto-step {\n    display: flex;\n    gap: 18px;\n    align-items: flex-start;\n    padding: 20px 0;\n    border-bottom: 1px solid #edf2f7;\n  }\n\n\n  .howto-step:last-child {\n    border-bottom: none;\n  }\n\n\n  .step-number {\n    flex-shrink: 0;\n    width: 54px;\n    height: 54px;\n    background: #007b8c;\n    color: #ffffff;\n    border-radius: 50%;\n    display: flex;\n    align-items: center;\n    justify-content: center;\n    font-weight: 700;\n    font-size: 18px;\n  }\n\n\n  .step-content {\n    flex: 1;\n  }\n\n\n  .step-content h3 {\n    margin-bottom: 6px;\n  }\n\n\n  .step-content p {\n    color: #4a5568;\n    margin: 0;\n  }\n\n\n  .specifications-table-wrapper {\n    overflow-x: auto;\n  }\n\n\n  .specifications-table {\n    width: 100%;\n    border-collapse: collapse;\n  }\n\n\n  .specifications-table th,\n  .specifications-table td {\n    padding: 14px 16px;\n    border-bottom: 1px solid #edf2f7;\n    text-align: left;\n    vertical-align: top;\n  }\n\n\n  .specifications-table th {\n    width: 35%;\n    background: #f8fafc;\n    color: #4a5568;\n    font-weight: 700;\n  }\n\n\n  .procurement-section {\n    background: #f8fafc;\n  }\n\n\n  .faq-item {\n    border-bottom: 1px solid #edf2f7;\n    padding: 18px 0;\n  }\n\n\n  .faq-item:last-child {\n    border-bottom: 0;\n  }\n\n\n  .faq-item summary {\n    cursor: pointer;\n    color: #0f4c5c;\n    font-size: 18px;\n    font-weight: 700;\n    padding-right: 20px;\n  }\n\n\n  .faq-answer {\n    padding: 12px 0 0;\n    color: #4a5568;\n  }\n\n\n  .faq-answer p {\n    margin: 0;\n  }\n\n\n  .product-final {\n    background: #0f4c5c;\n    color: #ffffff;\n    padding: 35px;\n    border-radius: 14px;\n    margin-top: 35px;\n  }\n\n\n  .product-final h2 {\n    color: #ffffff;\n  }\n\n\n  .product-final p {\n    margin: 0;\n  }\n\n\n  @media (max-width: 1000px) {\n\n    .grade-selection-grid {\n      grid-template-columns: repeat(2, minmax(0, 1fr));\n    }\n\n  }\n\n\n  @media (max-width: 900px) {\n\n    .performance-grid {\n      grid-template-columns: 1fr;\n    }\n\n  }\n\n\n  @media (max-width: 768px) {\n\n    .accurafil-product-description {\n      font-size: 15px;\n    }\n\n    .accurafil-product-description h2 {\n      font-size: 25px;\n    }\n\n    .benefits-grid {\n      grid-template-columns: 1fr;\n    }\n\n    .grade-selection-grid {\n      grid-template-columns: 1fr;\n    }\n\n    .product-intro,\n    .product-section,\n    .product-final {\n      padding: 22px;\n    }\n\n    .specifications-table th,\n    .specifications-table td {\n      padding: 11px;\n    }\n\n    .synthetic-callout {\n      flex-direction: column;\n    }\n\n  }\n\n\u003c\/style\u003e","brand":"AccuraFil","offers":[{"title":"24 x 12 x 12 \/ MERV 15 \/ 4V","offer_id":48344511643956,"sku":"11-21-1810020-195-0","price":185.82,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0716\/7767\/3780\/files\/12x24-4V_syn_V_Bank-PAck_of_2.jpg?v=1786477068"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0716\/7767\/3780\/collections\/7.1FV-BankSyntheticAirFilter-1.jpg?v=1788570844","url":"https:\/\/accurafil.com\/collections\/v-bank-air-filters.oembed","provider":"AccuraFil","version":"1.0","type":"link"}