AccuraFIL HEPA panel filter advertisement with text and filter illustration.
Diagram of a accurafil mini pleat filter with labeled dimensions on a white background

HEPA Laminar Flow Panel Filter

$428.01From $236.25

Engineered Air Filters for Industrial & Commercial HVAC Systems

Select Filter Specifications:

Actual Size: W × H (in.): Choose an option

Actual Size: W × H (in.): Choose an option
12 x 24
24 x 24
30 x 24
48 x 24

Filter Depth (in.): Choose an option

Filter Depth (in.): Choose an option
2.6
2.96
3.55
4.6

HEPA Rating (EN 779): Choose an option

HEPA Rating (EN 779): Choose an option
H13
H14
U15
Add to Wishlist
SKU:

icons of acceptable form of secured payment
Description
HEPA LF — Laminar Flow HEPA Air Filter — H13 / H14 / U15 | AccuraFil

About This Product

Ultra-High Efficiency HEPA Filtration for Critical Environments

  • AccuraFil HEPA LF uses a mini-pleat media pack to deliver an ultra-large filtering area, maximizing airflow while maintaining minimum pressure drop and extending filter service life.
  • Available in H13, H14, and U15 grades per EN 1822, achieving MPPS efficiencies up to ≥99.9995% and DOP efficiencies at 0.3μ up to ≥99.9999%.
  • Standard media is micro glass fiber paper; PTFE membrane media is available as an option for applications requiring superior chemical resistance or enhanced moisture tolerance.
  • Every filter undergoes individual scan testing per EN 1822 — test results are labeled directly on each unit for full traceability in regulated and audited environments.
  • Standard frame is an extruded anodized aluminum profile. GI, standard Al, and stainless steel frame options are available. Designed for terminal housing and laminar flow system mounting.
Custom HEPA Laminar Flow Panel Filters

Precision-engineered for cleanrooms and critical manufacturing environments — custom-built to your exact dimensions, efficiency ratings, frame materials, and sealing requirements for superior fit, aseptic performance, and long-lasting filtration reliability.

HEPA-Grade Filtration Technology

  • Mini-pleat media pack for maximum surface area in compact depth
  • H13 / H14 / U15 grades per EN 1822
  • MPPS efficiency up to ≥99.9995% (U15)
  • DOP efficiency @ 0.3μ up to ≥99.9999%
  • PTFE membrane media option available

Premium Construction

  • Micro glass fiber paper media (PTFE optional)
  • Hot melt bead media separator for pleat stability
  • Extruded anodized Al frame (GI / Al / SS options)
  • Compressed metal mesh face guard, powder coated
  • Two-part polyurethane media sealant
  • Seamless PU / Neoprene gasket

Performance & Compliance

  • Individual scan tested per EN 1822 — results labeled on each unit
  • Low pressure drop for reduced energy consumption
  • Max 90% relative humidity operation
  • Max temperature 70°C / 158°F
  • Terminal housing & laminar flow system compatible

Filter Grade Comparison

EN 1822 Grades & Efficiency

Grade MPPS Efficiency DOP @ 0.3μ
H13 ≥ 99.95% ≥ 99.99%
H14 ≥ 99.995% ≥ 99.999%
U15 ≥ 99.9995% ≥ 99.9999%

Available Filter Depths

2.6" Compact terminal housing
2.96" Standard laminar flow fit
3.55" Mid-depth AHU frames
4.6" High-capacity installations
5.96" Maximum DHC & service life

Technical Data

Technical Specifications & Compliance

Filter Type Mini Pleat Construction
Filter Grades (EN 1822)
H13 H14 U15
MPPS Efficiency ≥99.95% / ≥99.995% / ≥99.9995%
DOP Efficiency @ 0.3μ ≥99.99% / ≥99.999% / ≥99.9999%
Filter Media Micro Glass Fiber Paper (PTFE optional)
Media Separator Hot Melt Bead
Frame Extruded Al Anodized / SS / GI
Face Guard Compressed Metal Mesh (Powder Coated)
Media Sealant Two-Part Poly-Urethane
Gasket Seamless PU / Neoprene
Filter Depths 2.6" / 2.96" / 3.55" / 4.6" / 5.96"
Max Humidity 90% RH
Max Temperature 70°C / 158°F
Max Pressure Drop 2.00" wg (Recommended)
Testing Standard EN 1822 — Individually Scan Tested
Mounting Options Terminal Housing, Laminar Flow System

Industry Applications

Critical Industry Application Profiles

Hospitals & Surgical Suites

H14 pathogen removal for operating rooms, isolation wards, and critical care environments.

Pharmaceutical Manufacturing

GMP-compliant H13 / H14 filtration for aseptic filling, cleanroom air showers, and LAF units.

ISO Cleanrooms

H14 / U15 achieves ISO Class 3–5 air purity when installed in laminar flow ceiling arrays.

Semiconductor Fabrication

Ultra-low particle environments protected by U15 mini-pleat panels at critical tool stations.

Food & Beverage

H13 filtration in hygienic zones; stainless steel frame option for washdown-rated areas.

Every HEPA LF unit is individually scan tested per EN 1822 — test results labeled directly on each filter for complete quality traceability.

Selection Guide

How to Select the Right HEPA LF Filter for Your System

  1. Identify your required EN 1822 filter grade

    H13 (≥99.95% MPPS) is recommended for hospitals, laboratories, and pharmaceutical production areas. H14 (≥99.995%) is required for ISO Class 3–5 cleanrooms, aseptic filling lines, and critical surgical environments. U15 (≥99.9995%) serves the most demanding semiconductor fabs and ultra-clean process environments.

  2. Choose standard or PTFE media

    Standard micro glass fiber paper media suits the majority of HVAC and cleanroom applications. Select PTFE membrane media for environments requiring superior chemical resistance, humidity tolerance above 90% RH, or applications involving aggressive process gases and solvents.

  3. Select the appropriate filter depth

    Choose 2.6" or 2.96" for compact terminal housing and space-constrained laminar flow modules. Select 3.55" or 4.6" for standard laminar flow ceiling systems and AHU final filter banks. Choose 5.96" for maximum dust holding capacity and the longest achievable service intervals.

  4. Confirm frame material and gasket compatibility

    Standard extruded anodized aluminum frames suit most terminal housing and laminar flow systems. Specify GI or SS frames for corrosion-sensitive or washdown environments. Confirm PU or Neoprene gasket compatibility with your housing seal interface before ordering.

  5. Verify system pressure drop constraints

    Confirm your fan or blower capacity can maintain design airflow within the maximum recommended final pressure drop of 2.00" wg. The mini-pleat geometry delivers minimum initial resistance, extending the usable life before this limit is reached.

Product Comparison

HEPA LF vs. Conventional HEPA Box Filters

Compared to conventional deep-pleat HEPA box filters, AccuraFil HEPA LF mini-pleat panels deliver significantly greater filtration surface area within an equivalent frame footprint. The result is lower initial pressure drop, higher airflow capacity per unit, and extended service intervals — reducing the total cost of filter ownership in high-change-frequency cleanroom and hospital environments.

The individual EN 1822 scan test on every unit distinguishes the HEPA LF from batch-tested alternatives, providing the per-unit performance assurance required by pharmaceutical GMP, hospital infection control, and ISO cleanroom qualification protocols.

Frequently Asked Questions

Product FAQ

What is a HEPA LF Laminar Flow HEPA Air Filter?

A HEPA LF (Laminar Flow) filter is a high-efficiency HEPA-grade air filter built with mini-pleat media pack construction. The mini-pleat geometry maximizes filtration surface area within a compact panel profile, delivering ultra-high airflow at low pressure drop. It is designed for laminar flow systems, terminal housing, and critical cleanroom applications requiring H13, H14, or U15 filtration per EN 1822.

What EN 1822 grades are available for the HEPA LF filter?

AccuraFil HEPA LF filters are available in H13, H14, and U15 grades per EN 1822, with MPPS efficiencies of ≥99.95%, ≥99.995%, and ≥99.9995% respectively. H14 and U15 are suitable for the most demanding pharmaceutical aseptic manufacturing, semiconductor fabrication, and ISO Class 3–4 cleanroom environments.

How is each HEPA LF filter tested?

Every AccuraFil HEPA LF filter undergoes individual scan testing per EN 1822 to ensure completely leak-proof performance. Individual test results are printed directly on each filter unit, providing full traceability and quality assurance for regulated industries including pharmaceutical GMP and hospital infection control.

What frame options are available for the HEPA LF filter?

The standard HEPA LF frame is an extruded, anodized aluminum profile. Optional frame materials include galvanized iron (GI), standard aluminum (Al), and stainless steel (SS) for applications requiring enhanced corrosion resistance, hygienic washdown construction, or compatibility with specific terminal housing interfaces.

What filter depths are available for the HEPA LF?

AccuraFil HEPA LF filters are available in five depth options: 2.6", 2.96", 3.55", 4.6", and 5.96" to accommodate a wide range of terminal housings, laminar flow ceiling modules, and final-filter AHU configurations. The 5.96" depth provides maximum dust holding capacity and the longest service intervals.

AccuraFil · Clean Air Solutions

Ready to Get Started?

Contact our engineering team to discuss your specialized HEPA filtration requirements for your critical environment.