AccuraFil carbon V-bank air filter with four V-shaped pleated panels and a black frame, designed for molecular filtration in commercial and industrial facilities like hospitals and cleanrooms.
AccuraFil carbon V-bank air filter with four V-shaped pleated panels and a black frame, designed for molecular filtration in commercial and industrial facilities like hospitals and cleanrooms.
AccuraFil carbon V-bank air filter with four V-shaped pleated panels and a black frame, designed for molecular filtration in commercial and industrial facilities like hospitals and cleanrooms.
Isometric view diagram of an AccuraFil four-V bank air filter, designed for industrial facilities such as hospitals, cleanrooms, and data centers.

V-Bank Activated Carbon Air Filter

$524.00From $327.50

Price / Filter: $332.20

Engineered Air Filters for Industrial & Commercial HVAC Systems

Select Filter Specifications:

Nominal Size: W × H × D (in.): Choose an option

Nominal Size: W × H × D (in.): Choose an option
20 x 24 x 12
24 x 24 x 12

MERV Rating (ASHRAE 52.2): MERV 15

MERV Rating (ASHRAE 52.2): MERV 15
MERV 15

No. of V-Banks: 4V

No. of V-Banks: 4V
4V
Add to Wishlist
SKU:

icons of acceptable form of secured payment
Description

Activated Carbon & High-Efficiency HVAC Filtration

V-Bank Activated Carbon Air Filter

AccuraFil V-Bank Activated Carbon Air Filters combine particulate filtration and molecular gas-phase filtration in a single high-efficiency HVAC filter. The V-bank configuration uses extended-surface media to provide efficient airflow while the activated carbon media is designed to adsorb gaseous contaminants.

Available in MERV 10, MERV 13, and MERV 15 configurations per ASHRAE 52.2, the filter uses micro-granulate activated carbon embedded between synthetic media layers. The corrosion-resistant ABS plastic frame and 20 mm peripheral header provide a durable, space-efficient configuration for compatible commercial, industrial, healthcare, pharmaceutical, and other HVAC applications requiring both particulate and molecular contaminant control.

Key Benefits

Dual Particulate & Molecular Filtration

Combines MERV-rated particulate filtration with activated carbon adsorption in one V-bank filter configuration.

60% CTC Activated Carbon

Micro-granulate activated carbon provides a large active surface area for adsorption of a range of gaseous contaminants.

Low-Resistance V-Bank Design

Extended-surface V-bank geometry provides efficient use of the available filter footprint while supporting low pressure resistance.

Corrosion-Resistant ABS Frame

The non-metal ABS frame is designed for resistance to corrosion in applications where reactive gases or humid operating conditions are a concern.

Technical Specifications

Filter Type V-Bank Activated Carbon Air Filter
Filtration Mode Dual Particulate and Molecular Filtration
MERV Efficiency MERV 15
Filtration Standard ASHRAE 52.2
Filter Depth 12"
Filter Media Micro-Granulate Adsorbent Carbon Particles in Dual-Layer Synthetic Media
Carbon Content 60% CTC Activated Carbon Micro Granules
Frame Material ABS Plastic — Corrosion-Resistant, Non-Metal
Header Construction 20 mm Peripheral Header
Gaseous Contaminants VOCs / Vehicle Exhaust / SOx / NOx / Ammonia / Ozone / Other Gaseous Compounds
Maximum Operating Temperature 131°F (55°C)
Recommended Final Pressure Drop 1.50" w.g.
Fire Classification UL900 Classified

60% CTC Activated Carbon for Molecular Filtration

The V-Bank Carbon Filter uses micro-granulate activated carbon embedded within dual-layer synthetic media. The 60% CTC activated carbon configuration provides a high surface area for adsorption of gaseous contaminants while the synthetic media provides the particulate filtration component.

This dual-mode design allows particulate and molecular filtration to occur within a single filter unit, simplifying HVAC filtration where both airborne particles and gaseous contaminants are part of the filtration requirement.

60% CTC Activated Carbon

Activated carbon micro granules provide the molecular adsorption component of the filter, targeting VOCs, vehicle exhaust, SOx, NOx, ammonia, ozone, and other gaseous contaminants.

Targeted Gaseous Contaminants

The activated carbon media is designed for molecular adsorption of gaseous contaminants commonly encountered in commercial, industrial, transportation-influenced, and specialized HVAC environments.

VOCs Vehicle Exhaust SOx NOx Ammonia Ozone Other Gaseous Compounds

V-Bank Design for Efficient HVAC Airflow

The V-bank configuration arranges the filtration media into multiple angled sections, increasing the effective media surface area within the available filter footprint. The mini-pleated configuration is designed to support efficient airflow while providing space for activated carbon loading.

The 12-inch filter depth provides a substantial media and carbon volume for applications requiring combined particulate and molecular filtration.

Choosing the Right MERV Rating

Select the appropriate particulate filtration efficiency based on facility requirements, indoor air quality objectives, system design, airflow, and allowable pressure drop.

MERV 10

Suitable for general commercial and light industrial HVAC applications requiring particulate filtration together with molecular contaminant control.

MERV 13

Higher-efficiency particulate filtration for healthcare, commercial buildings, laboratories, and other applications where increased indoor air quality control is required.

MERV 15

High-efficiency particulate filtration for demanding applications, including pharmaceutical and controlled-environment HVAC systems.

ABS Frame & 20 mm Header Construction

The V-Bank Carbon Filter uses a corrosion-resistant ABS plastic frame rather than a conventional metal frame. This non-metal construction is intended for environments where corrosion resistance is important.

A 20 mm peripheral header provides the filter mounting interface for compatible HVAC filter racks and housings.

Always verify the existing filter housing dimensions, header configuration, sealing arrangement, and installation requirements before ordering a replacement filter.

Commercial & Industrial HVAC Applications

AccuraFil V-Bank Activated Carbon Filters are designed for applications where both particulate and gaseous contaminant control are required, including:

  • Hospitals and healthcare facilities
  • Pharmaceutical and biotechnology facilities
  • Data centers and mission-critical facilities
  • Commercial office buildings
  • Urban and transportation-influenced buildings
  • Laboratories and controlled environments
  • Food and beverage processing facilities
  • Industrial HVAC systems
  • Outdoor-air intake systems requiring gas-phase filtration

Reliable Performance in High-Demand Environments

The combination of MERV particulate filtration and activated carbon molecular adsorption makes the V-Bank Carbon Filter suitable for HVAC systems exposed to mixed contaminant loads.

Hospitals & Healthcare

Combined particulate and molecular filtration can help address complex airborne contaminant conditions in healthcare HVAC environments.

Pharmaceutical Manufacturing

Higher-efficiency MERV configurations provide particulate filtration while activated carbon targets gaseous contaminants in compatible pharmaceutical and controlled environments.

Data Centers

Activated carbon filtration can help address gaseous contaminants that may contribute to corrosion concerns for sensitive electronic equipment, while MERV filtration provides particulate control.

Urban & Transportation Facilities

The activated carbon component is designed to target gaseous pollutants associated with vehicle exhaust and outdoor-air intake conditions.

Food & Beverage Processing

Activated carbon filtration can be used to target selected gaseous and odor-related contaminants in compatible food-processing and storage HVAC environments.

Dual-Mode Particulate & Molecular Filtration

Particulate Filtration

MERV-rated synthetic media captures airborne particulate matter while providing the filtration stage required for the selected HVAC application.

Molecular Adsorption

Activated carbon micro granules provide adsorption of selected gaseous contaminants and VOCs.

Large Effective Media Area

V-bank mini-pleat geometry maximizes effective media surface area within the available filter footprint.

Simplified Filter Configuration

Combining particulate and molecular filtration in one filter unit can simplify applications that would otherwise require separate filtration stages.

How to Select the Right V-Bank Carbon Filter

  1. Identify the Target Contaminants

    Determine whether the application requires particulate filtration, molecular filtration, or both. Target gaseous contaminants may include VOCs, vehicle exhaust, SOx, NOx, ammonia, and ozone.

  2. Select the Required MERV Rating

    Choose MERV 10, MERV 13, or MERV 15 based on the required particulate filtration efficiency and facility application.

  3. Verify the 12-Inch Filter Depth

    Confirm that the AHU or filter housing can accommodate the 12-inch filter depth and the required 20 mm peripheral header.

  4. Check Temperature and Pressure-Drop Requirements

    Verify that the operating environment does not exceed 131°F (55°C) and that the HVAC system can accommodate the recommended final pressure drop of 1.50" w.g.

V-Bank Carbon Filter vs. Separate Carbon & Particulate Stages

Traditional HVAC systems may use separate particulate filters and dedicated activated carbon stages. The AccuraFil V-Bank Carbon Filter combines both filtration functions into a single filter configuration, providing a compact approach for applications requiring particulate and molecular contaminant control.

The V-bank geometry provides extended media surface area while the activated carbon component provides molecular adsorption. The appropriate configuration depends on contaminant concentrations, required MERV efficiency, airflow, available installation depth, and the HVAC system's pressure-drop limitations.

Product Selection & Procurement

Before ordering a replacement V-Bank Carbon Filter, verify the actual filter dimensions, 12-inch depth, 20 mm header configuration, MERV rating, airflow requirements, pressure-drop limits, and compatibility with the existing HVAC housing or filter rack.

For applications requiring molecular filtration, identify the target gaseous contaminants and evaluate whether activated carbon adsorption is appropriate for the concentration and operating conditions.

AccuraFil provides commercial and industrial air filtration solutions for facility managers, HVAC contractors, mechanical engineers, healthcare organizations, pharmaceutical facilities, data-center operators, IAQ professionals, and procurement teams.

Frequently Asked Questions

What is a V-Bank activated carbon filter?

A V-Bank activated carbon filter combines particulate filtration with activated carbon molecular adsorption in a V-shaped filter configuration. AccuraFil's model uses synthetic MERV-rated media with micro-granulate activated carbon for dual-mode filtration.

What contaminants does the activated carbon filter target?

The supplied product specifications identify VOCs, vehicle exhaust, SOx, NOx, ammonia, ozone, and other gaseous compounds as target molecular contaminants.

What does 60% CTC mean?

CTC refers to Carbon Tetrachloride Activity, an established measure used to characterize activated carbon adsorption performance. The product uses 60% CTC activated carbon micro granules.

What MERV ratings are available?

The AccuraFil V-Bank Carbon Filter is available in MERV 10, MERV 13, and MERV 15 configurations according to the supplied product specifications.

Can one filter provide both particulate and gas-phase filtration?

Yes. The V-Bank Carbon Filter is designed as a dual-mode filter, combining MERV-rated particulate filtration media with activated carbon molecular adsorption in the same filter unit.

Why is the frame made from ABS plastic?

The supplied product specifications identify ABS as a corrosion-resistant, non-metal frame material. This construction is suitable for applications where resistance to corrosion is an important consideration.

What is the filter depth?

The specified filter depth is 12 inches. Verify the available installation depth and housing configuration before ordering.

What is the maximum operating temperature?

The specified maximum operating temperature is 131°F (55°C).

What is the recommended final pressure drop?

The recommended final pressure drop specified for the product is 1.50" w.g. Confirm the HVAC system can support the required pressure-drop conditions before installation.

AccuraFil V-Bank Activated Carbon Air Filters

AccuraFil V-Bank Activated Carbon Air Filters combine MERV-rated particulate filtration, 60% CTC activated carbon, extended-surface V-bank construction, and a corrosion-resistant ABS frame for commercial, industrial, healthcare, pharmaceutical, data center, and other HVAC applications requiring particulate and molecular contaminant control.