Pack of two - AccuraFil microglass 4V-bank air filter with white  mini-pleat filter panels, designed for industrial and commercial facilities.
Pack of two - AccuraFil microglass 2V-bank air filter with white  mini-pleat filter panels, designed for industrial and commercial facilities.
Blue AccuraFil microglass V-bank air filter with white  mini-pleat filter panels, designed for industrial and commercial facilities.
Blue AccuraFil microglass V-bank air filter with white  mini-pleat filter panels, designed for industrial and commercial facilities.
Exploded 3D model of an AccuraFIL V-BankMicroglass  Air Filter, detailing its components and features for commercial and industrial facilities like hospitals and cleanrooms.
Comparison chart of AccuraFil V-Bank Synthetic and Fiberglass filters, showing key specifications for industrial and commercial use.
Isometric view diagram of an AccuraFil four-V bank air filter, designed for industrial facilities such as hospitals, cleanrooms, and data centers.

V-Bank Microglass Air Filter – 12x24x12 – Pack of 2

$218.24From $129.58

Price / Filter: $74.38

Engineered Air Filters for Industrial & Commercial HVAC Systems

Select Filter Specifications:

Nominal Size: W × H × D (in.): 24 x 12 x 12

Nominal Size: W × H × D (in.): 24 x 12 x 12
24 x 12 x 12

MERV Rating (ASHRAE 52.2): Choose an option

MERV Rating (ASHRAE 52.2): Choose an option
MERV 11
MERV 14
MERV 15

No. of V-Banks: Choose an option

No. of V-Banks: Choose an option
4V
2V
Add to Wishlist
SKU:

icons of acceptable form of secured payment
Description

High-Efficiency Glass Fiber HVAC Filtration

V-Bank Microglass Air Filter

AccuraFil V-Bank Microglass Air Filters combine mini-pleat glass fiber media with rigid V-bank construction to provide high-efficiency particulate filtration with efficient airflow and low resistance. The V-bank configuration increases the effective media surface area within a compact filter footprint, making the design suitable for high-airflow HVAC applications.

Available in MERV 11, MERV 13, MERV 14, and MERV 15 configurations according to ASHRAE 52.2, corresponding to M6, F7, F8, and F9 classifications under EN 779. The filter uses synthetic glass fiber media with polyurethane potting, thermoplastic bead separators, and a non-metallic ABS plastic frame with a 20 mm header.

The fully incinerable construction is designed for compatible pharmaceutical, healthcare, food processing, commercial, industrial, VAV, air handler, and built-up filter bank applications where high airflow, compact construction, and simplified filter disposal are important considerations.

Key Benefits

High-Efficiency Microglass Media

Synthetic glass fiber media provides high-efficiency particulate filtration across MERV 11 through MERV 15 configurations.

Mini-Pleat V-Bank Design

The extended-surface mini-pleat configuration increases effective media area within a compact rigid V-bank filter footprint.

Polyurethane-Potted Media Pack

Polyurethane potting bonds the media pack to the frame and provides enhanced burst resistance for demanding airflow conditions.

Fully Incinerable Construction

Non-metallic filter construction supports simplified end-of-life disposal in facilities where incineration is required or preferred.

Technical Specifications

Filter Type V-Bank Rigid Box Filter
Filter Design Mini-Pleat V-Bank Configuration
MERV Efficiency MERV 11 / MERV 14 / MERV 15
EN 779 Grades M6 / F8 / F9
Filtration Standard ASHRAE 52.2
Filter Media Synthetic Glass Fiber Media
Media Bonding Polyurethane Potting
Media Separator Thermoplastic Bead Separators (Hot Melt Beads)
Frame Material ABS Plastic — Non-Metallic
Header Construction 20 mm Header
Maximum Operating Velocity 625 fpm / 3.175 m/s
Maximum Operating Temperature 176°F (80°C)
Final Pressure Drop 1.50" w.g.
Maximum Recommended Pressure Drop 2.00" w.g.
Disposal Fully Incinerable, Non-Metallic Construction
Fire Classification UL900 Classified

Glass Fiber Media & Mini-Pleat Performance

The V-Bank Microglass Filter uses synthetic glass fiber media arranged in a mini-pleat configuration to provide a large effective filtration area within a compact rigid filter design. The increased media area helps distribute airflow across the filter while supporting the selected MERV efficiency.

Polyurethane potting secures the media pack within the frame and provides enhanced burst resistance for demanding airflow applications. The combination of mini-pleat geometry, rigid V-bank construction, and potted media is intended to provide consistent filter performance in compatible HVAC systems.

High-Strength Glass Fiber Media

Synthetic glass fiber media combined with polyurethane potting provides a rigid, durable media pack designed for high-airflow HVAC applications and demanding installation environments.

Choosing the Right MERV Rating

Select the appropriate MERV efficiency based on the required particulate filtration level, facility application, airflow requirements, and HVAC system pressure-drop limitations.

MERV 11

Suitable for general commercial ventilation and HVAC applications requiring enhanced particulate filtration.

MERV 13

Provides higher-efficiency particulate filtration for offices, hotels, light healthcare, and commercial HVAC applications.

MERV 14

Higher-efficiency filtration for hospitals, laboratories, LEED buildings, and other applications requiring increased particulate control.

MERV 15

High-efficiency particulate filtration for demanding applications including pharmaceutical, controlled-environment, and critical HVAC systems.

V-Bank Mini-Pleat Design for High Airflow

The V-bank configuration arranges multiple angled media sections within the rigid filter frame, increasing the effective filtration surface area compared with a flat filter occupying the same general footprint. The mini-pleat construction allows a large amount of filtration media to be incorporated into a compact filter design.

This extended-surface configuration is designed to support high airflow and low resistance while maintaining the structural advantages of a rigid box-style filter. The maximum recommended operating velocity is 625 fpm (3.175 m/s).

MERV & EN 779 Filter Grade Tiers

EN 779: M6 MERV 11 General commercial ventilation
EN 779: F7 MERV 13 Offices, hotels & light healthcare
EN 779: F8 MERV 14 Hospitals, laboratories & LEED buildings
EN 779: F9 MERV 15 Pharmaceutical, cleanroom & critical applications

ABS Frame & 20 mm Header Construction

The V-Bank Microglass Filter uses a non-metallic ABS plastic frame with a 20 mm header. The rigid frame provides structural support for the mini-pleat media pack while maintaining the compact V-bank configuration.

The non-metallic construction contributes to the filter's fully incinerable design, allowing the filter to be considered for applications where simplified disposal is important.

Always verify the existing HVAC housing, filter bank dimensions, header configuration, sealing arrangement, and installation requirements before ordering a replacement filter.

Fully Incinerable Non-Metallic Construction

The V-Bank Microglass Filter is constructed without conventional metallic separators, using a non-metallic ABS frame and thermoplastic bead separators. This construction is designed to allow the complete filter assembly to be incinerated without requiring separation of metallic filter components.

Fully incinerable construction can simplify end-of-life handling for facilities where spent filters require controlled disposal, including compatible pharmaceutical, healthcare, food processing, and other specialized environments.

Commercial & Industrial HVAC Applications

AccuraFil V-Bank Microglass Filters are designed for applications requiring high-efficiency particulate filtration, extended media surface area, and a compact rigid V-bank configuration, including:

  • Hospitals and healthcare facilities
  • Pharmaceutical and biotechnology facilities
  • ISO cleanroom and controlled environments
  • Commercial office buildings
  • Data centers and mission-critical facilities
  • Food and beverage processing facilities
  • Air handling units and packaged HVAC systems
  • Variable Air Volume (VAV) systems
  • Built-up filter banks and multi-cell filtration systems
  • Industrial HVAC applications requiring compact high-efficiency filtration

Reliable Performance in High-Demand Environments

The rigid V-bank construction, glass fiber media, and polyurethane-potted media pack make this filter suitable for HVAC applications requiring consistent particulate filtration under demanding airflow conditions.

Hospitals & Healthcare

Higher-efficiency MERV configurations provide particulate filtration for compatible healthcare HVAC applications. The fully incinerable construction can also simplify disposal of spent filters where controlled disposal procedures are required.

Pharmaceutical & Cleanroom Applications

MERV 14 and MERV 15 configurations provide high-efficiency particulate filtration for compatible controlled environments. Non-metallic, incinerable construction can support facilities where filter disposal procedures are an important consideration.

Commercial & Office Buildings

MERV 11 through MERV 14 configurations provide a range of particulate filtration options for commercial HVAC systems where efficient airflow and compact filter construction are important.

VAV & Air Handling Systems

The rigid V-bank construction and polyurethane-potted media pack are designed for demanding air handler and variable-airflow applications where maintaining structural integrity is important.

Food Processing Facilities

Non-metallic and fully incinerable construction can be advantageous for compatible food-processing HVAC applications where simplified end-of-life disposal is important.

High-Efficiency Particulate Filtration Performance

High-Efficiency Particle Capture

Available from MERV 11 through MERV 15 to accommodate different particulate filtration requirements.

Large Effective Media Area

Mini-pleat V-bank geometry increases effective media surface area within a compact rigid filter configuration.

Enhanced Media Integrity

Polyurethane potting secures the glass fiber media pack within the frame and provides enhanced burst resistance.

Simplified Disposal

Non-metallic construction and thermoplastic bead separators support fully incinerable filter disposal without component separation.

How to Select the Right V-Bank Microglass Filter

  1. Select the Required MERV Rating

    Choose MERV 11 for general commercial ventilation. Choose MERV 13 for offices, hotels, and light healthcare applications. Choose MERV 14 for hospitals, laboratories, and higher-efficiency HVAC applications. Choose MERV 15 for pharmaceutical, cleanroom, and other critical environments requiring high-efficiency particulate filtration.

  2. Verify Airflow & Pressure-Drop Requirements

    Confirm that system airflow does not exceed the specified maximum operating velocity of 625 fpm / 3.175 m/s. Verify that the HVAC system can accommodate the specified pressure-drop conditions, including the 1.50" w.g. final pressure drop and 2.00" w.g. maximum recommended pressure drop.

  3. Confirm Housing Compatibility

    Verify the actual filter face dimensions, housing depth, header configuration, sealing arrangement, and installation orientation before ordering. The specified configuration uses an ABS plastic frame with a 20 mm header.

  4. Confirm Temperature & Disposal Requirements

    Confirm that operating temperature does not exceed 176°F (80°C). Where filter incineration is required or preferred, verify that the facility's disposal procedures are compatible with fully incinerable filter construction.

V-Bank Microglass Filter vs. Bag & Standard Box Filters

Compared with conventional bag-style filters, the rigid V-bank design provides a fixed filter geometry rather than a flexible pocket configuration. The mini-pleat glass fiber construction provides a large effective media area within the rigid housing format, making the design suitable for systems where compact construction and high airflow are important.

Compared with conventional standard box-type pleated filters, the V-bank configuration allows more effective media area to be incorporated within the filter footprint. The polyurethane-potted media pack and thermoplastic bead separators also provide structural support for the pleated media during operation.

The best filter configuration depends on required MERV efficiency, airflow, available installation depth, pressure-drop limitations, housing dimensions, and facility disposal requirements.

Product Selection & Procurement

Before ordering a replacement V-Bank Microglass Filter, verify the actual filter dimensions, required MERV rating, filter depth, frame and header configuration, airflow requirements, maximum operating velocity, pressure-drop limitations, and compatibility with the existing HVAC housing or filter bank.

Do not select a replacement filter based only on the nominal size printed on an existing filter. Confirm the physical dimensions and housing configuration to reduce the risk of installation problems, poor fit, inadequate sealing, return shipping expenses, restocking charges, and project delays.

AccuraFil supplies commercial and industrial air filtration products for facility managers, HVAC contractors, mechanical engineers, healthcare organizations, pharmaceutical facilities, data center operators, and procurement teams.

Frequently Asked Questions

What is a V-Bank Microglass Filter?

A V-Bank Microglass Filter is a rigid box-style HVAC filter that uses glass fiber media arranged in a V-shaped mini-pleat configuration. The design increases effective media surface area within a compact filter footprint and is intended for high-efficiency particulate filtration applications.

What MERV ratings are available?

The AccuraFil V-Bank Microglass Filter is available in MERV 11, MERV 13, MERV 14, and MERV 15 according to the supplied product specifications. These correspond to M6, F7, F8, and F9 classifications under EN 779.

What type of filter media does it use?

The filter uses synthetic glass fiber media. The media pack is secured using polyurethane potting and incorporates thermoplastic bead separators to maintain pleat spacing.

What is the advantage of the mini-pleat V-bank design?

The mini-pleat V-bank configuration increases effective media surface area within a compact rigid filter footprint. This design is intended to support high airflow and efficient particulate filtration while maintaining a rigid filter structure.

What are thermoplastic bead separators?

Thermoplastic bead separators, also called hot melt beads, are non-metallic separator elements used to maintain consistent pleat spacing throughout the media pack.

Is the V-Bank Microglass Filter fully incinerable?

The supplied product specifications identify the filter as fully incinerable and non-metallic. This construction is designed to simplify end-of-life disposal where facility procedures call for filter incineration.

What is the maximum operating velocity?

The specified maximum operating velocity is 625 fpm (3.175 m/s). HVAC system operating conditions should be verified before installation.

What is the maximum operating temperature?

The specified maximum operating temperature is 176°F (80°C).

What frame and header does the filter use?

The specified configuration uses a non-metallic ABS plastic frame with a 20 mm header. Housing compatibility should be verified before ordering.

What should I verify before ordering a replacement?

Verify the actual filter dimensions, MERV rating, filter depth, frame and header configuration, housing dimensions, sealing arrangement, airflow requirements, and pressure-drop limitations. Matching the physical filter and housing configuration helps avoid fit problems, return shipping charges, restocking fees, and delays.

AccuraFil V-Bank Microglass Air Filters

AccuraFil V-Bank Microglass Air Filters combine synthetic glass fiber media, mini-pleat V-bank construction, polyurethane potting, thermoplastic bead separators, and a non-metallic ABS frame to provide high-efficiency particulate filtration for commercial, healthcare, pharmaceutical, industrial, VAV, air handler, and built-up filter bank applications. Available in MERV 11 through MERV 15 configurations with fully incinerable construction for compatible disposal requirements.