V-Bank Synthetic Filter | High-Efficiency V-Bank Filters
AccuraFil V-bank air filter with four V-shaped mini-pleat panels and a black frame, designed for commercial and industrial facilities like hospitals and cleanrooms.
Exploded 3D model of an AccuraFIL V-Bank Synthetic Air Filter, detailing its components and features for commercial and industrial facilities like hospitals and cleanrooms.
Comparison chart of AccuraFil V-Bank Synthetic and Fiberglass filters, showing key specifications for industrial and commercial use.
Isometric view diagram of an AccuraFil four-V bank air filter, designed for industrial facilities such as hospitals, cleanrooms, and data centers.

V-Bank Synthetic Air Filter – MERV 15 – 4V

$247.68From $147.06

Price / Filter: $147.06

Engineered Air Filters for Industrial & Commercial HVAC Systems

Select Filter Specifications:

Nominal Size: W × H × D (in.): Choose an option

Nominal Size: W × H × D (in.): Choose an option
24 x 20 x 12
24 x 24 x 12

MERV Rating (ASHRAE 52.2): MERV 15

MERV Rating (ASHRAE 52.2): MERV 15
MERV 15

No. of V-Banks: 4V

No. of V-Banks: 4V
4V
Add to Wishlist
SKU:

icons of acceptable form of secured payment
Description

High-Efficiency Synthetic HVAC Filtration

V-Bank Synthetic Air Filter

AccuraFil V-Bank Synthetic Air Filters combine high-efficiency synthetic media, mini-pleat construction, and V-bank geometry in a rigid box-style HVAC filter designed for high airflow and low resistance. The extended-surface design provides a large effective filtration area within a compact filter footprint.

Available in MERV 11, MERV 13, MERV 14, and MERV 15 configurations according to ASHRAE 52.2, corresponding to M6, F7, F8, and F9 classifications under EN 779. The filter uses high-efficiency synthetic media with thermoplastic bead separators and an ABS plastic frame with a 20 mm header. Its rigid construction is designed for variable and turbulent airflow applications, including VAV systems, air handlers, built-up filter banks, healthcare facilities, pharmaceutical environments, data centers, and commercial HVAC systems.

Key Benefits

High-Efficiency Synthetic Media

Synthetic filtration media provides efficient particulate filtration across MERV 11 through MERV 15 configurations while supporting resistance to moisture and demanding airflow conditions.

Mini-Pleat V-Bank Design

Extended-surface mini-pleat geometry maximizes effective media area within the available filter footprint to support high airflow with reduced resistance.

Turbulence-Resistant Construction

Rigid box construction and thermoplastic bead separators help maintain pleat geometry and filtration performance under variable and turbulent airflow conditions.

Fully Incinerable Construction

The non-metallic filter construction is fully incinerable, allowing end-of-life disposal without separating metallic frame components from the filter media.

Technical Specifications

Filter Type V-Bank Synthetic Air Filter — Rigid Box
Filter Grades MERV 15
Filtration Standard ASHRAE 52.2
EN 779 Grades F9
Filter Media High-Efficiency Synthetic Media
Media Separator Thermoplastic Bead Separators (Hot Melt Beads)
Frame Material ABS Plastic
Header Construction 20 mm Header
Maximum Operating Temperature 176°F (80°C)
Final Pressure Drop 1.50" w.g.
Maximum Recommended Pressure Drop 2.00" w.g.
Maximum Operating Velocity 625 fpm / 3.175 m/s
Disposal Fully Incinerable, Non-Metallic Construction
Fire Classification UL900 Classified

High-Efficiency Synthetic Media Performance

The V-Bank Synthetic Filter uses high-efficiency synthetic filtration media arranged in a mini-pleat configuration. The extended media surface area allows the filter to provide efficient particulate filtration while maintaining the compact rigid-box format required by many HVAC installations.

The synthetic media construction is designed for demanding operating conditions where moisture exposure, variable airflow, and turbulence can affect conventional filter designs. The filter is available from MERV 11 through MERV 15 to accommodate different particulate filtration requirements.

Durable Synthetic Filtration

High-efficiency synthetic media provides a combination of particulate filtration, moisture resistance, and durability for demanding HVAC applications.

MERV & EN 779 Filter Grade Selection

Select the appropriate filter grade according to the facility's particulate filtration requirements, HVAC design, airflow conditions, and allowable pressure drop.

EN 779 M6

MERV 11

Suitable for general commercial ventilation and applications requiring moderate particulate filtration performance.

EN 779 F7

MERV 13

Higher-efficiency particulate filtration for offices, hotels, light healthcare, and commercial HVAC applications.

EN 779 F8

MERV 14

Higher filtration efficiency for hospitals, laboratories, LEED buildings, and other demanding commercial applications.

EN 779 F9

MERV 15

High-efficiency particulate filtration for pharmaceutical, ISO cleanroom, healthcare, and critical HVAC environments.

V-Bank Mini-Pleat Design for High Airflow

The V-bank configuration divides the filter media into angled sections, increasing the effective filtration surface area available within the filter footprint. Combined with the mini-pleat design, this configuration supports high airflow while minimizing resistance.

The extended-surface construction is designed to provide greater media utilization than conventional flat panel arrangements while maintaining a compact rigid box configuration suitable for air handlers, filter banks, and VAV systems.

Performance Under Variable & Turbulent Airflow

The rigid box construction and thermoplastic bead separators are designed to maintain consistent pleat geometry under variable airflow and turbulent operating conditions. This makes the V-Bank Synthetic Filter particularly suitable for HVAC systems where airflow demand changes during operation.

Maximum Operating Velocity

The specified maximum operating velocity is 625 fpm (3.175 m/s).

Final Pressure Drop

The specified final pressure drop is 1.50" w.g..

Maximum Recommended Pressure Drop

The maximum recommended pressure drop is 2.00" w.g..

Turbulence-Resistant Design

Rigid construction and thermoplastic bead separators help maintain pleat spacing during variable airflow conditions.

ABS Frame & 20 mm Header Construction

The V-Bank Synthetic Filter uses a non-metallic ABS plastic frame designed to provide a lightweight and durable enclosure for the synthetic media pack.

The 20 mm header provides the mounting interface for compatible HVAC filter racks and built-up filter bank systems.

Always verify the existing housing dimensions, header configuration, sealing arrangement, and installation orientation before ordering a replacement filter.

Fully Incinerable Non-Metallic Construction

The V-Bank Synthetic Filter uses a non-metallic, fully incinerable construction. The filter can be disposed of by incineration without separating metallic frame components from the filter media.

This construction can simplify end-of-life handling for facilities where incinerable filter disposal is preferred or required, including compatible pharmaceutical, healthcare, food processing, and other controlled environments.

Commercial & Industrial HVAC Applications

AccuraFil V-Bank Synthetic Filters are designed for high-efficiency particulate filtration in a wide range of commercial and industrial HVAC applications, including:

  • Variable Air Volume (VAV) systems
  • Commercial office buildings and hotels
  • Hospitals and healthcare facilities
  • Pharmaceutical and biotechnology facilities
  • Laboratories and controlled environments
  • Data centers and mission-critical facilities
  • Built-up HVAC filter banks
  • Air handling units and commercial HVAC systems
  • High-humidity HVAC environments
  • Food processing facilities requiring compatible incinerable filter construction

Reliable Performance in High-Demand Environments

The combination of high-efficiency synthetic media, mini-pleat V-bank geometry, and rigid box construction makes the filter suitable for HVAC systems exposed to high airflow, variable operating conditions, and demanding maintenance requirements.

VAV & Turbulent Airflow Systems

The rigid filter construction and thermoplastic bead separators are designed to help maintain media geometry and filtration performance under variable airflow conditions.

Hospitals & Healthcare

High-efficiency MERV configurations provide particulate filtration for compatible healthcare HVAC systems, while the non-metallic construction supports simplified incinerable disposal.

Pharmaceutical Manufacturing

MERV 14 and MERV 15 configurations provide high-efficiency particulate filtration for compatible pharmaceutical and controlled environments where airflow stability and end-of-life handling are important considerations.

Data Centers

High-efficiency synthetic filtration helps provide particulate control for sensitive electronic environments, while the rigid V-bank design supports demanding continuous HVAC operation.

High-Humidity Environments

Synthetic media is designed to resist moisture-related degradation, supporting applications where elevated humidity is an important operating consideration.

Built-Up Filter Banks

The rigid box configuration with ABS frame and 20 mm header is designed for installation in compatible cell housings and multi-filter HVAC bank configurations.

High-Airflow Synthetic Filtration Performance

Large Effective Media Area

Mini-pleat V-bank geometry increases the effective filtration surface area within the available filter footprint.

Lower Resistance

The extended-surface design is engineered to support efficient airflow with controlled pressure resistance.

Durable Synthetic Media

Synthetic media provides a resilient filtration structure for variable airflow and elevated-humidity HVAC conditions.

Reduced Filter Handling Complexity

Fully incinerable non-metallic construction can simplify end-of-life handling where incineration is an applicable disposal method.

How to Select the Right V-Bank Synthetic Filter

  1. Identify the Required MERV Rating

    Select MERV 11, MERV 13, MERV 14, or MERV 15 according to the particulate filtration requirements of the facility and HVAC application.

  2. Verify Airflow & Pressure-Drop Requirements

    Confirm that system airflow remains within the specified maximum operating velocity of 625 fpm (3.175 m/s) and that the HVAC system can accommodate the specified pressure-drop conditions.

  3. Confirm Housing Compatibility

    Verify that the existing housing accepts the required V-bank rigid box configuration with ABS frame and 20 mm header. Confirm actual filter dimensions, mounting arrangement, and sealing requirements before ordering.

  4. Verify Operating Conditions & Disposal Requirements

    Confirm operating temperature does not exceed 176°F (80°C). Where incinerable disposal is applicable, confirm that the facility's disposal process accepts the filter's fully incinerable non-metallic construction.

V-Bank Synthetic Filter vs. Bag Filters & Standard Box Filters

Compared with conventional bag-style filters, the V-Bank Synthetic Filter uses a rigid box configuration and mini-pleat V-bank geometry. This provides a more structurally stable format for applications exposed to variable or turbulent airflow while maximizing the available media surface area within the filter footprint.

Compared with conventional standard box filters, the mini-pleat V-bank configuration is designed to provide high effective media area and efficient airflow in a compact rigid construction. Synthetic media additionally provides moisture resistance and a fully incinerable non-metallic construction for compatible applications.

The appropriate filter selection depends on required MERV efficiency, airflow, pressure drop, housing configuration, operating environment, and disposal requirements.

Product Selection & Procurement

Before ordering a replacement V-Bank Synthetic Filter, verify the actual filter dimensions, MERV rating, V-bank configuration, ABS frame and 20 mm header requirements, airflow, pressure-drop limitations, and compatibility with the existing HVAC housing or filter bank.

For variable-airflow systems, confirm that the application operates within the specified maximum velocity and pressure-drop limits. Verify that the filter construction is suitable for the operating temperature and humidity conditions.

Where incinerable disposal is required, confirm that the facility's disposal process accepts fully incinerable non-metallic filter construction without requiring separation of components.

AccuraFil provides commercial and industrial HVAC filtration solutions for facility managers, HVAC contractors, mechanical engineers, healthcare organizations, pharmaceutical facilities, data center operators, filter-bank designers, and procurement teams.

Frequently Asked Questions

What is a V-Bank Synthetic Filter?

A V-Bank Synthetic Filter is a rigid box-style HVAC filter that uses high-efficiency synthetic media arranged in a V-bank mini-pleat configuration. The design provides an extended filtration surface within a compact footprint and is intended for efficient airflow and demanding HVAC applications.

What MERV ratings are available?

The AccuraFil V-Bank Synthetic Filter is available in MERV 11, MERV 13, MERV 14, and MERV 15 according to the supplied product specifications. These correspond to EN 779 classifications M6, F7, F8, and F9 respectively.

What are the advantages of synthetic media?

High-efficiency synthetic media provides a resilient filtration structure and is designed to resist moisture-related degradation. This makes it suitable for compatible HVAC applications involving variable airflow, turbulence, or elevated humidity.

What are thermoplastic bead separators?

Thermoplastic bead separators, also known as hot melt beads, maintain the spacing between the mini-pleats in the synthetic media pack. Their non-metallic construction contributes to the filter's fully incinerable design.

How does the V-Bank Synthetic Filter perform under turbulent airflow?

The rigid box construction and thermoplastic bead separators are designed to help maintain pleat geometry and filtration performance under variable and turbulent airflow conditions. This makes the filter suitable for VAV systems and other applications where airflow conditions fluctuate during operation.

What is the maximum operating velocity?

The specified maximum operating velocity is 625 fpm (3.175 m/s). HVAC system airflow should be verified against this limit before specifying the filter.

What frame and header configuration does the filter use?

The specified configuration uses a non-metallic ABS plastic frame with a 20 mm header. Verify that the existing HVAC filter housing or built-up filter bank is compatible with this configuration before ordering.

Is the V-Bank Synthetic Filter fully incinerable?

Yes. The supplied product specifications identify the filter as having a fully incinerable, non-metallic construction. Confirm that the facility's disposal process accepts this disposal method before use.

What is the maximum operating temperature?

The specified maximum operating temperature is 176°F (80°C).

What is the recommended final pressure drop?

The specified final pressure drop is 1.50" w.g., with a maximum recommended pressure drop of 2.00" w.g.. Confirm that the HVAC system can support the required pressure-drop conditions before ordering.

AccuraFil V-Bank Synthetic Air Filters

AccuraFil V-Bank Synthetic Air Filters combine high-efficiency synthetic media, mini-pleat V-bank geometry, rigid box construction, and a non-metallic ABS frame for high-airflow commercial and industrial HVAC applications. Available in MERV 11, MERV 13, MERV 14, and MERV 15 configurations, the design provides efficient particulate filtration, turbulence-resistant construction, moisture resistance, and fully incinerable non-metallic disposal for compatible applications.