AccuraFil standard capacity HEPA air filter with deep pleated microglass fiber media and coated galvanized steel frame, designed for particulate filtration in commercial and industrial facilities like data centers, hospitals and cleanrooms.
Comparison chart of different AccuraFil HEPA Fiberglass air filters, (HEPA high Volume vs High Capacity Versus Standard Capacity Filter, showing filter images and key specifications for industrial and commercial use.

HEPA Standard-Capacity Air Filter

$381.60From $238.50

Price / Filter: $245.50

Engineered Air Filters for Industrial & Commercial HVAC Systems

Select Filter Specifications:

HEPA-Actual Size: W x H x D (in.): Choose an option

HEPA-Actual Size: W x H x D (in.): Choose an option
24 x 24 x 11.5
23 3/8 x 23 3/8 x 11.5

HEPA Rating (EN 1822): Choose an option

HEPA Rating (EN 1822): Choose an option
H13 / 99.99%
E12 / 99.97%

HEPA-Frame Design: GI DTF - Neoprene Gasket on the Downstream Side

HEPA-Frame Design: GI DTF - Neoprene Gasket on the Downstream Side
GI DTF - Neoprene Gasket on the Downstream Side
Add to Wishlist
SKU:

icons of acceptable form of secured payment
Description

High-Efficiency Industrial & Commercial HVAC Filtration

Standard Capacity HEPA Air Filter 24x24x12

AccuraFil Standard Capacity HEPA filters feature a deep-pleated construction designed to provide a large effective filtration media area within a compact filter footprint. This standard-capacity HEPA design is engineered for commercial and industrial HVAC systems requiring high-efficiency particulate filtration, reliable airflow, and dependable filter performance.

Manufactured with micro glass fiber media and corrugated aluminum separators with hemmed edges, the SC HEPA filter is available in EN 1822 E12, H13, and H14 grades. Every filter is individually scan tested according to EN 1822, with test results documented and affixed to each unit for traceability.

Key Benefits

Deep-Pleat HEPA Design

Deep-pleated construction provides a large effective filtration surface area for high-efficiency particulate filtration and dependable airflow performance.

High-Efficiency HEPA Filtration

Micro glass fiber media is available in EN 1822 E12, H13, and H14 grades for demanding commercial, industrial, healthcare, and controlled-environment applications.

Individually Scan Tested Per EN 1822

Each filter is individually scan tested according to EN 1822, with test results documented and affixed to the filter for unit-level traceability.

Durable Sealed Construction

Corrugated aluminum separators, two-part polyurethane sealant, and PU or Neoprene gasket options provide a durable filter construction and housing sealing system.

Technical Specifications

Filter Type Standard Capacity Deep-Pleat HEPA Filter
EN 1822 Grades E12 / H13 / H14
MPPS Efficiency 99.5% / 99.95% / 99.995%, respectively
Efficiency at 0.3 µm 99.97% / 99.99% / 99.999%, respectively
Filter Media Glass Fine Microfibers
Media Separator Corrugated Aluminum Separator with Hemmed Edges
Rated Airflow 1200 CFM
Initial Pressure Drop 1.10 in. w.c.
Recommended Final Pressure Drop 2.00 in. w.g.
Frame Materials GI / Stainless Steel / Aluminum / or MDF
Media Sealant Two-Part Polyurethane
Gasket Options Seamless Polyurethane (PU) / Neoprene
Maximum Operating Temperature 80°C (176°F)
Fire Classification UL900 Classified
Testing Individually Tested Per EN 1822 For Leak-Proof Performance

Choosing the Right EN 1822 HEPA Grade

Select the appropriate HEPA efficiency grade based on the required particulate removal performance, cleanroom classification, HVAC system design, and applicable facility requirements.

E12 HEPA Filter

99.5% MPPS efficiency. Suitable for general industrial applications and selected cleanroom pre-filtration requirements.

H13 HEPA Filter

99.95% MPPS efficiency. Designed for demanding applications including hospitals, pharmaceutical manufacturing, and controlled cleanroom environments.

H14 HEPA Filter

99.995% MPPS efficiency. Intended for applications requiring very high-efficiency particulate filtration, including critical cleanroom and aseptic environments.

Standard Capacity HEPA vs. High Capacity HEPA

The Standard Capacity (SC) HEPA uses a deep-pleat construction designed for dependable high-efficiency filtration across commercial and industrial HVAC applications. The High Capacity (HC) design uses a higher pleat count within the deep-pleat construction to provide more effective media area within the same external footprint.

The SC design is rated for 1200 CFM at an initial pressure drop of 1.10 in. w.c., while the HC design is rated for 1700 CFM at the same initial pressure drop. The appropriate design should be selected based on airflow requirements, filter service expectations, housing configuration, and maintenance priorities.

HEPA Filter Construction & Sealing

Glass Fine Microfiber Media

Glass fine microfiber media provides the filtration medium for high-efficiency HEPA applications requiring E12, H13, or H14 performance.

Corrugated Aluminum Separators

Hemmed-edge corrugated aluminum separators help maintain consistent pleat spacing and airflow distribution through the deep-pleated media pack.

Polyurethane Media Sealant

Two-part polyurethane sealant provides a durable bond between the media pack and frame.

PU & Neoprene Gasket Options

Seamless polyurethane and Neoprene gasket options are available according to the required housing sealing configuration.

HEPA Filter Frame Designs: Double-Turn Flange vs. Box-No-Header

HEPA filters are available with different frame and header designs to match the existing filter housing or holding frame. Choosing the correct frame style is important for proper installation, sealing, filter support, and maintenance access. Always match the replacement HEPA filter to the existing housing design rather than selecting a frame based only on nominal filter size.

Box-No-Header Frame

A box-no-header design uses a rigid box-style filter frame without a conventional projecting header flange. This configuration is intended for compatible housings and mounting systems where the filter is installed directly into the filter bank or support structure.

When to Use It Use a box-no-header configuration when the existing filter bank or housing is designed to accept a headerless box-style HEPA filter and provides its own support, sealing, or clamping arrangement.
Important: Frame design is not interchangeable simply because the nominal filter size is the same. Before ordering a replacement HEPA filter, verify the existing housing's frame style, flange/header design, actual filter dimensions, gasket or sealing arrangement, and installation orientation. Selecting the wrong frame design can cause installation problems, inadequate sealing, return shipping costs, restocking charges, and project delays.

⚠️ Important: Verify Actual HEPA Filter Dimensions Before Ordering

HEPA filters must be ordered and matched by their actual dimensions, not nominal dimensions. Incorrect measurements can result in installation misfit, return shipping fees, restocking charges, and project delays.

Nominal Size 24" × 24" × 12"
Actual Dimensions 23 3/8" × 23 3/8" × 11 1/2"

Before placing your order: Verify the actual width, height, and depth of your existing HEPA filter and confirm compatibility with your filter housing. This simple step can help prevent misfit issues, unnecessary return shipping costs, restocking charges, and installation delays.

Applications

AccuraFil Standard Capacity HEPA filters are designed for demanding commercial, industrial, healthcare, pharmaceutical, and controlled environment HVAC applications, including:

  • Pharmaceutical and biotech manufacturing facilities
  • GMP production environments
  • Hospitals and healthcare facilities
  • Operating theatres and critical care environments
  • ISO-classified cleanrooms
  • Aseptic filling and controlled manufacturing areas
  • Industrial and commercial air-handling units
  • HVAC systems requiring individually tested HEPA filtration

Reliable Performance in High-Demand Environments

The deep-pleated Standard Capacity HEPA design provides a large effective filtration area for demanding HVAC applications where high-efficiency particulate removal, reliable airflow, and individually tested filter performance are important operating requirements.

Pharmaceutical & Biotech Manufacturing

H13 and H14 configurations are suited to pharmaceutical, biotechnology, GMP manufacturing, aseptic processing, and controlled cleanroom environments requiring individually scan tested HEPA filtration.

Hospitals & Healthcare

H13 and H14 configurations support demanding healthcare HVAC applications including operating theatres, isolation areas, critical care spaces, and other environments requiring high-efficiency particulate filtration.

ISO Cleanrooms

High-efficiency HEPA filtration is suitable for controlled environments where documented filter testing, validated particulate removal, and reliable air-handling performance are required.

Industrial & Commercial AHUs

E12 through H13 configurations support demanding industrial and commercial air-handling applications where deep-pleat HEPA filtration, reliable airflow, and serviceable filter construction are required.

Individually Scan Tested Per EN 1822

Every AccuraFil Standard Capacity HEPA filter is individually scan tested according to EN 1822 rather than relying solely on batch or statistical sampling. Testing evaluates the finished filter across its face to identify potential leaks or integrity issues.

Test results are documented and affixed to each filter, providing unit-level traceability for procurement, commissioning, validation, and controlled-environment documentation.

MPPS Efficiency and EN 1822 Classification

EN 1822 classifies high-efficiency filters using Most Penetrating Particle Size (MPPS) efficiency. The AccuraFil Standard Capacity HEPA product family is available in E12, H13, and H14 grades with progressively higher certified MPPS efficiency.

Efficiency values at 0.3 µm are also provided for reference when comparing HEPA filtration requirements with specifications that use fixed-particle-size efficiency.

Standard Capacity HEPA vs. V-Bank HEPA

The HEPA HV Filter is the top-performing model in the AccuraFil range, utilizing a V-Bank mini-pleat design to provide the highest media surface area (291 sq.ft.). This allows it to handle 2000 CFM while maintaining the lowest resistance (1.05 in wc), offering superior airflow and energy efficiency compared to traditional deep-pleat designs.

In contrast, the HC HEPA and SC HEPA filters use deep-pleat designs. The HC supports 1700 CFM and the SC supports 1200 CFM — both at a 1.10 in wc initial pressure drop. All three models are available in the same EN 1822 grade range (E12, H13, H14); the choice depends on housing depth, target airflow volume, and energy efficiency priorities.

The best HEPA filter selection depends on the required EN 1822 grade, airflow, initial and final pressure drop, filter dimensions, housing configuration, installation depth, and maintenance requirements.

Product Selection & Procurement

When replacing a Standard Capacity HEPA filter, verify the nominal filter dimensions, actual dimensions, EN 1822 efficiency grade, rated airflow, initial pressure drop, final pressure-drop requirement, frame material, gasket type, operating temperature, and compatibility with the existing filter housing.

AccuraFil provides industrial and commercial air filtration products for facility managers, HVAC contractors, mechanical engineers, pharmaceutical facilities, healthcare organizations, cleanroom professionals, and procurement teams.

Frequently Asked Questions

What is a Standard Capacity HEPA filter?

A Standard Capacity HEPA filter is a deep-pleated high-efficiency air filter designed to provide a large filtration media area within a conventional filter footprint. The SC design supports dependable high-efficiency filtration for commercial and industrial HVAC systems.

What EN 1822 grades are available?

The AccuraFil Standard Capacity HEPA filter is available in E12, H13, and H14 grades, with MPPS efficiencies of 99.5%, 99.95%, and 99.995%, respectively.

What does MPPS efficiency mean?

MPPS means Most Penetrating Particle Size. EN 1822 uses MPPS efficiency to evaluate HEPA filter performance at the particle size where filtration is most challenging.

What is individual scan testing per EN 1822?

Individual scan testing means each filter unit is tested across its face according to EN 1822 for leak-proof performance rather than relying solely on statistical batch sampling. Test results are documented and affixed to each filter for traceability.

How does the Standard Capacity HEPA compare with the High Capacity HEPA?

Both SC and HC HEPA filters use deep-pleat construction and the same EN 1822 grade range. The HC design uses a higher pleat count and is rated for 1700 CFM at 1.10 in. w.c. initial pressure drop, while the SC design is rated for 1200 CFM at the same initial pressure drop.

What frame materials are available?

Frame options include galvanized steel (GI), stainless steel (SS), aluminum (AL), and MDF, depending on the required application and filter configuration.

What gasket options are available?

Seamless polyurethane (PU) and Neoprene gasket options are available, depending on the required housing sealing configuration.

AccuraFil Standard Capacity HEPA Filters

AccuraFil Standard Capacity HEPA filters combine deep-pleated glass microfiber media, individually tested EN 1822 performance, durable separator and sealing construction, and multiple frame and gasket options for demanding commercial, industrial, healthcare, pharmaceutical, and cleanroom HVAC applications.