Deep-Pleat HEPA Design
Deep-pleated construction provides a large effective filtration surface area for high-efficiency particulate filtration and dependable airflow performance.
High-Efficiency Industrial & Commercial HVAC Filtration
AccuraFil Standard Capacity HEPA filters feature a deep-pleated construction designed to provide a large effective filtration media area within a compact filter footprint. This standard-capacity HEPA design is engineered for commercial and industrial HVAC systems requiring high-efficiency particulate filtration, reliable airflow, and dependable filter performance.
Manufactured with micro glass fiber media and corrugated aluminum separators with hemmed edges, the SC HEPA filter is available in EN 1822 E12, H13, and H14 grades. Every filter is individually scan tested according to EN 1822, with test results documented and affixed to each unit for traceability.
Deep-pleated construction provides a large effective filtration surface area for high-efficiency particulate filtration and dependable airflow performance.
Micro glass fiber media is available in EN 1822 E12, H13, and H14 grades for demanding commercial, industrial, healthcare, and controlled-environment applications.
Each filter is individually scan tested according to EN 1822, with test results documented and affixed to the filter for unit-level traceability.
Corrugated aluminum separators, two-part polyurethane sealant, and PU or Neoprene gasket options provide a durable filter construction and housing sealing system.
| Filter Type | Standard Capacity Deep-Pleat HEPA Filter |
|---|---|
| EN 1822 Grades | E12 / H13 / H14 |
| MPPS Efficiency | 99.5% / 99.95% / 99.995%, respectively |
| Efficiency at 0.3 µm | 99.97% / 99.99% / 99.999%, respectively |
| Filter Media | Glass Fine Microfibers |
| Media Separator | Corrugated Aluminum Separator with Hemmed Edges |
| Rated Airflow | 1200 CFM |
| Initial Pressure Drop | 1.10 in. w.c. |
| Recommended Final Pressure Drop | 2.00 in. w.g. |
| Frame Materials | GI / Stainless Steel / Aluminum / or MDF |
| Media Sealant | Two-Part Polyurethane |
| Gasket Options | Seamless Polyurethane (PU) / Neoprene |
| Maximum Operating Temperature | 80°C (176°F) |
| Fire Classification | UL900 Classified |
| Testing | Individually Tested Per EN 1822 For Leak-Proof Performance |
Select the appropriate HEPA efficiency grade based on the required particulate removal performance, cleanroom classification, HVAC system design, and applicable facility requirements.
99.5% MPPS efficiency. Suitable for general industrial applications and selected cleanroom pre-filtration requirements.
99.95% MPPS efficiency. Designed for demanding applications including hospitals, pharmaceutical manufacturing, and controlled cleanroom environments.
99.995% MPPS efficiency. Intended for applications requiring very high-efficiency particulate filtration, including critical cleanroom and aseptic environments.
The Standard Capacity (SC) HEPA uses a deep-pleat construction designed for dependable high-efficiency filtration across commercial and industrial HVAC applications. The High Capacity (HC) design uses a higher pleat count within the deep-pleat construction to provide more effective media area within the same external footprint.
The SC design is rated for 1200 CFM at an initial pressure drop of 1.10 in. w.c., while the HC design is rated for 1700 CFM at the same initial pressure drop. The appropriate design should be selected based on airflow requirements, filter service expectations, housing configuration, and maintenance priorities.
Glass fine microfiber media provides the filtration medium for high-efficiency HEPA applications requiring E12, H13, or H14 performance.
Hemmed-edge corrugated aluminum separators help maintain consistent pleat spacing and airflow distribution through the deep-pleated media pack.
Two-part polyurethane sealant provides a durable bond between the media pack and frame.
Seamless polyurethane and Neoprene gasket options are available according to the required housing sealing configuration.
HEPA filters are available with different frame and header designs to match the existing filter housing or holding frame. Choosing the correct frame style is important for proper installation, sealing, filter support, and maintenance access. Always match the replacement HEPA filter to the existing housing design rather than selecting a frame based only on nominal filter size.
HEPA filters must be ordered and matched by their actual dimensions, not nominal dimensions. Incorrect measurements can result in installation misfit, return shipping fees, restocking charges, and project delays.
Before placing your order: Verify the actual width, height, and depth of your existing HEPA filter and confirm compatibility with your filter housing. This simple step can help prevent misfit issues, unnecessary return shipping costs, restocking charges, and installation delays.
AccuraFil Standard Capacity HEPA filters are designed for demanding commercial, industrial, healthcare, pharmaceutical, and controlled environment HVAC applications, including:
The deep-pleated Standard Capacity HEPA design provides a large effective filtration area for demanding HVAC applications where high-efficiency particulate removal, reliable airflow, and individually tested filter performance are important operating requirements.
H13 and H14 configurations are suited to pharmaceutical, biotechnology, GMP manufacturing, aseptic processing, and controlled cleanroom environments requiring individually scan tested HEPA filtration.
H13 and H14 configurations support demanding healthcare HVAC applications including operating theatres, isolation areas, critical care spaces, and other environments requiring high-efficiency particulate filtration.
High-efficiency HEPA filtration is suitable for controlled environments where documented filter testing, validated particulate removal, and reliable air-handling performance are required.
E12 through H13 configurations support demanding industrial and commercial air-handling applications where deep-pleat HEPA filtration, reliable airflow, and serviceable filter construction are required.
Every AccuraFil Standard Capacity HEPA filter is individually scan tested according to EN 1822 rather than relying solely on batch or statistical sampling. Testing evaluates the finished filter across its face to identify potential leaks or integrity issues.
Test results are documented and affixed to each filter, providing unit-level traceability for procurement, commissioning, validation, and controlled-environment documentation.
EN 1822 classifies high-efficiency filters using Most Penetrating Particle Size (MPPS) efficiency. The AccuraFil Standard Capacity HEPA product family is available in E12, H13, and H14 grades with progressively higher certified MPPS efficiency.
Efficiency values at 0.3 µm are also provided for reference when comparing HEPA filtration requirements with specifications that use fixed-particle-size efficiency.
The HEPA HV Filter is the top-performing model in the AccuraFil range, utilizing a V-Bank mini-pleat design to provide the highest media surface area (291 sq.ft.). This allows it to handle 2000 CFM while maintaining the lowest resistance (1.05 in wc), offering superior airflow and energy efficiency compared to traditional deep-pleat designs.
In contrast, the HC HEPA and SC HEPA filters use deep-pleat designs. The HC supports 1700 CFM and the SC supports 1200 CFM — both at a 1.10 in wc initial pressure drop. All three models are available in the same EN 1822 grade range (E12, H13, H14); the choice depends on housing depth, target airflow volume, and energy efficiency priorities.
The best HEPA filter selection depends on the required EN 1822 grade, airflow, initial and final pressure drop, filter dimensions, housing configuration, installation depth, and maintenance requirements.
When replacing a Standard Capacity HEPA filter, verify the nominal filter dimensions, actual dimensions, EN 1822 efficiency grade, rated airflow, initial pressure drop, final pressure-drop requirement, frame material, gasket type, operating temperature, and compatibility with the existing filter housing.
AccuraFil provides industrial and commercial air filtration products for facility managers, HVAC contractors, mechanical engineers, pharmaceutical facilities, healthcare organizations, cleanroom professionals, and procurement teams.
A Standard Capacity HEPA filter is a deep-pleated high-efficiency air filter designed to provide a large filtration media area within a conventional filter footprint. The SC design supports dependable high-efficiency filtration for commercial and industrial HVAC systems.
The AccuraFil Standard Capacity HEPA filter is available in E12, H13, and H14 grades, with MPPS efficiencies of 99.5%, 99.95%, and 99.995%, respectively.
MPPS means Most Penetrating Particle Size. EN 1822 uses MPPS efficiency to evaluate HEPA filter performance at the particle size where filtration is most challenging.
Individual scan testing means each filter unit is tested across its face according to EN 1822 for leak-proof performance rather than relying solely on statistical batch sampling. Test results are documented and affixed to each filter for traceability.
Both SC and HC HEPA filters use deep-pleat construction and the same EN 1822 grade range. The HC design uses a higher pleat count and is rated for 1700 CFM at 1.10 in. w.c. initial pressure drop, while the SC design is rated for 1200 CFM at the same initial pressure drop.
Frame options include galvanized steel (GI), stainless steel (SS), aluminum (AL), and MDF, depending on the required application and filter configuration.
Seamless polyurethane (PU) and Neoprene gasket options are available, depending on the required housing sealing configuration.
AccuraFil Standard Capacity HEPA filters combine deep-pleated glass microfiber media, individually tested EN 1822 performance, durable separator and sealing construction, and multiple frame and gasket options for demanding commercial, industrial, healthcare, pharmaceutical, and cleanroom HVAC applications.